TY - JOUR A1 - Kallweit, Stephan A1 - Kaminsky, R. A1 - Rossi, M. A1 - Morbiducci, U. T1 - Time resolved PIV technique for high temporal resolution measurements of prosthetic heart valves fluid dynamics / Kaminsky, R. ; Rossi, M. ; Morbiducci, U. ; Scalise, L. ; Catellini, P. ; Kallweit, S. ; Verdonck, P. ; Grigioni, M. JF - The International Journal of Artificial Organs. 28 (2005), H. 9 Y1 - 2005 SN - 1724-6040 N1 - Abstracts: XXXII Annual ESAO Congress, 5-8 October 2005, Bologna - Italy SP - 946 ER - TY - JOUR A1 - Kallweit, Stephan A1 - Kaminsky, R. A1 - Rossi, M. A1 - Morbiducci, U. T1 - 2D PIV Study of the flow downstream : Two prototypes of a ney monoleaflet artificial aortic heart valve prosthesis / Kaminsky, R. ; Kramm, K. ; Weber, H. J. ; Simons, A. P. ; Kallweit, S. ; Verdonck, P. R. JF - The International Journal of Artificial Organs. 28 (2005), H. 9 Y1 - 2005 SN - 1724-6040 N1 - Abstracts: XXXII Annual ESAO Congress, 5-8 October 2005, Bologna - Italy SP - 921 ER - TY - JOUR A1 - Kallweit, Stephan A1 - Kaminsky, R. A1 - Rossi, M. A1 - Morbiducci, U. T1 - 3D PIV measurements of prosthetic heart valve dynamics / Kaminsky, R. ; Rossi, M. ; Morbiducci, U. ; Scalise, L. ; Castellini, P. ; Kallweit, S. ; Verdonck, P. ; Grigioni, M. JF - The International Journal of Artificial Organs. 28 (2005), H. 9 Y1 - 2005 SN - 1724-6040 N1 - Abstracts: XXXII Annual ESAO Congress, 5-8 October 2005, Bologna - Italy SP - 868 ER - TY - JOUR A1 - Kallweit, Stephan A1 - Kaminsky, R. A1 - Rossi, M. A1 - Scalise, L. T1 - PIV Measurements with high temporal Resolution behind Artificial Heart Valves / Kaminsky, R. ; Rossi, M. ; Scalise, L. ; Kallweit, S. ; Verdonck, P. JF - Proceedings of the 6th International Symposium on Particle Image Velocimetry Y1 - 2005 N1 - link zum abstract PB - Caltech CY - Pasadena, CA ER - TY - JOUR A1 - Kaminsky, Randolph A1 - Simons, Antoine A1 - Gatzweiler, Karl-Heinz A1 - Weber, Hans-Joachim T1 - Flow visualization by means of PIV of an artificial aortic heart valve fixed into a mock aorta JF - Acta Mechanica Slovaka 2-A. 9 (2005) Y1 - 2005 SP - 343 EP - 348 ER - TY - JOUR A1 - Kaminsky, Randolph A1 - Weber, Hans-Joachim A1 - Simons, Antoine A1 - Kallweit, Stephan A1 - Kramm, K. A1 - Verdonck, Pascale T1 - Comparison of the flow downstream two prototypes of a new monoleaflet artificial aortic heart valve by means of PIV visualization JF - Computer methods in biomechanics and biomedical engineering. 8 (2005), H. 4, Suppl. 1 Y1 - 2005 SN - 1476-8259 SP - 159 EP - 160 ER - TY - CHAP A1 - Karimi, Iman A1 - Butenweg, Christoph A1 - Toll, Britta T1 - Vulnerability assessment of industrial facilities T2 - Proceedings of the Tenth International Conference on Civil, Structural and Environmental Engineering Computing : [Rome, Italy, 30. August - 2. September 2005] / ed. by B. H. V. Topping Y1 - 2005 SN - 1-905088-00-0 U6 - http://dx.doi.org/10.4203/ccp.81.34 SP - 34, 73 EP - 75 PB - Civil-Comp Press CY - Stirling ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Kirsch, Ansgar A1 - Kolymbas, Dimitrios T1 - Theoretische Untersuchung zur Ortsbruststabilität JF - Bautechnik : Zeitschrift für den gesamten Ingenieurbau Y1 - 2005 U6 - http://dx.doi.org/10.1002/bate.200590151 SN - 1437-0999 (E-Journal); 0005-6820 (Print); 0932-8351 (Print) N1 - Gedruckt in der Bibliothek Bayernallee vorhanden: 13 Z 177-2005 VL - Bd. 82 IS - H. 7 SP - 449 EP - 456 ER - TY - CHAP A1 - Kloock, Joachim P. A1 - Moreno, Lia A1 - Huachupoma, S. A1 - Xu, J. A1 - Wagner, Torsten A1 - Bratov, A. A1 - Doll, T. A1 - Vlasov, Y. A1 - Schöning, Michael Josef ED - Gerlach, Gerald T1 - Halbleiterbasierte Schwermetallsensorik auf der Basis von Chalkogenidgläsern für zukünftige „Lab on Chip“-Anwendungen T2 - 7. Dresdner Sensor-Symposium - Neue Herausforderungen und Anwendungen in der Sensortechnik Y1 - 2005 SN - 3-938863-29-3 SP - 221 EP - 224 PB - TUDpress, Verl. der Wissenschaften CY - Dresden ER -