TY - JOUR A1 - Kolymbas, Dimitrios A1 - Fellin, W. A1 - Kirsch, Ansgar T1 - Squeezing due to stress relaxation in foliated rock JF - International journal for numerical and analytical methods in geomechanics Y1 - 2006 U6 - http://dx.doi.org/10.1002/nag.530 SN - 1096-9853 (E-Journal); 0363-9061 (Print) VL - Vol. 30 IS - Iss. 13 SP - 1357 EP - 1367 ER - TY - JOUR A1 - Oertel, Mario A1 - Bung, Daniel B. T1 - Stability and scour development of bed material on crossbar block ramps JF - International journal of sediment research N2 - Block ramps are ecologically oriented drop structures with adequate energy dissipation and partially moderate flow velocities. A special case is given with crossbar block ramps, where the upstream and downstream level difference is reduced by a series of basins. To prevent the total structure from failing, the stability of single boulders within the crossbars and the bed material in between must be guaranteed. The present paper addresses the stability of bed material and scour development for various flow regimes. Any bed material erosion may affect the stability of the crossbar boulders, which in turn can result in major damages of the ramp. Therefore new design approaches are developed to choose an appropriate bed material size and to avoid failures of crossbar block ramp structures. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.ijsrc.2014.12.003 SN - 1001-6279 VL - 30 IS - 4 SP - 344 EP - 350 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Biener, Ernst A1 - Wemhoff, T. A1 - Bethke, H. T1 - Stability and settlement problems based on the example of the Blockland landfill in Bremen JF - Sardinia 95 : Fifth International Landfill Symposium ; (2 - 6 October 1995, S. Margheritadi Pula - Cagliari, Sardinia, Italy) ; proceedings / coord.: Thomas H. Christensen ... - Bd. 2 : Siting, lining, drainage & landfill mechanics Y1 - 1995 N1 - International Landfill Symposium <5, 1995, Santa Margherita, Pula> SP - 843 EP - 853 PB - CISA, Environmental Sanitary Engineering Centre CY - Cagliari ER - TY - JOUR A1 - Döring, Bernd A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Feldmann, Markus A1 - Kesti, Jyrki A1 - Lawson, Mark A1 - Botti, Andrea T1 - Steel solutions for enabling zero-energy buildings JF - Steel Construction - Design and Research Y1 - 2015 U6 - http://dx.doi.org/10.1002/stco.201510029 SN - 1867-0539 N1 - The 13th Nordic Steel Construction Conference, Tampere, 2015 (NSCC-2015) VL - 8 IS - 3 SP - 194 EP - 200 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Döring, Bernd A1 - Kendrick, C. A1 - Lawson, R. M. T1 - Thermal capacity of composite floor slabs JF - Energy and buildings Y1 - 2013 SN - 1872-6178 (E-Journal); 0378-7788 (Print) VL - Vol. 67 SP - 531 EP - 539 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kramer, Matthias A1 - Valero, Daniel A1 - Chanson, Hubert A1 - Bung, Daniel B. T1 - Towards reliable turbulence estimations with phase-detection probes: an adaptive window cross-correlation technique JF - Experiments in Fluids Y1 - 2019 U6 - http://dx.doi.org/10.1007/s00348-018-2650-9 SN - 1432-1114 VL - 60 EP - Article number 2 PB - Springer CY - Berlin ER - TY - JOUR A1 - Höttges, Jörg T1 - Turbulence and Mixing Mechanics in Compound Open Channel Flow / Arnold, Uwe; Höttges, Jörg; Rouvé, Gerhard JF - On cutoff ratios of curved channels : paper presented at the 23rd Congress of the IAHR, Ottawa, Canada, August 21 - 25, 1989 / G. J. Klaassen; B. H. J.van Zanten Y1 - 1990 N1 - Congress of the IAHR ; (23 : ; 1989.08.21-25 : ; Ottawa) PB - Delft Hydraulics CY - Delft ER - TY - JOUR A1 - Bung, Daniel B. A1 - Crookston, Brian M. A1 - Valero, Daniel T1 - Turbulent free-surface monitoring with an RGB-D sensor: the hydraulic jump case JF - Journal of Hydraulic Research Y1 - 2020 U6 - http://dx.doi.org/10.1080/00221686.2020.1844810 SN - 1814-2079 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Fellin, Wolfgang A1 - King, Julian A1 - Kirsch, Ansgar A1 - Oberguggenberger, Michael T1 - Uncertainty modelling and sensitivity analysis of tunnel face stability JF - Structural safety N2 - This paper proposes an approach to the choice and evaluation of engineering models with the aid of a typical application in geotechnics. An important issue in the construction of shallow tunnels, especially in weak ground conditions, is the tunnel face stability. Various theoretical and numerical models for predicting the necessary support pressure have been put forth in the literature. In this paper, we combine laboratory experiments performed at the University of Innsbruck with current methods of uncertainty and sensitivity analysis for assessing adequacy, predictive power and robustness of the models. The major issues are the handling of the twofold uncertainty of test results and of model predictions as well as the decision about what are the influential input parameters. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.strusafe.2010.06.001 SN - 0167-4730 VL - 32 IS - 6 SP - 402 EP - 410 PB - Elsevier CY - Amsterdam ER -