TY - CHAP A1 - Buda, Aurel A1 - Schürmann, Volker A1 - Wollert, Jörg T1 - Wireless technologies in factory automation T2 - Factory automation / ed. by Javier Silvestre-Blanes Y1 - 2010 SN - 978-953-7619-42-8 SP - 29 EP - 50 PB - Intech CY - London ER - TY - CHAP A1 - Schürmann, Volker A1 - Buda, Aurel A1 - Jonker, Stefan A1 - Palmhof, Norman A1 - Wollert, Jörg T1 - Wireless in future automotive applications T2 - Mobile and wireless communications network layer and circuit level design / ed. by Salma Ait Fares ... Y1 - 2010 SN - 978-953-307-042-1 SP - 71 EP - 92 PB - Intech CY - London ER - TY - BOOK A1 - Boonzaaijer, Karel A1 - Helmig, Ilka A1 - Bergerhausen, Johannes A1 - Beudaert, Matthieu T1 - Vision - space for imagination T2 - Vision - ruimte voor verbeelding Y1 - 2010 SN - 978-90-5856-357-6 N1 - Texte Engl. und Niederländ. PB - Stichting Kunstboek CY - Oostkamp ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 SP - 1 EP - 3 ER - TY - JOUR A1 - Garhofer, Gerhard A1 - Bek, Toke A1 - Boehm, Andreas G. A1 - Gherghel, Doina A1 - Grundwald, Juan A1 - Jeppesen, Peter A1 - Kergoat, Hélène A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Lovasik, John V. A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Orgul, Selim A1 - Schmetterer, Leopold T1 - Use of the retinal vessel analyzer in ocular blood flow research JF - Acta Ophthalmol N2 - The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. Y1 - 2010 U6 - http://dx.doi.org/10.1111/j.1755-3768.2009.01587.x SN - 1755-3768 VL - 88 IS - 7 SP - 717 EP - 722 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of Information Visualization Methods Eliminating Cross Talk in Multiple Sensing Units Investigated for a Light-Addressable Potentiometric Sensor JF - Analytical Chemistry (2010) Y1 - 2010 SN - 0003-2700 SP - 61 EP - 65 ER - TY - JOUR A1 - Akimbekov, N. Sh. A1 - Zhubanova, A. A. A1 - Mansurov, Z. A. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Use of Carbonized Rise Shell for the local treatment of wounds JF - Eurasian ChemTech Journal N2 - On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis. Y1 - 2010 U6 - http://dx.doi.org/10.18321/ectj35 SN - 2522-4867 VL - 12 IS - 2 SP - 133 EP - 138 PB - Institute of Combustion Problems CY - Almaty ER - TY - JOUR A1 - Haselgruber, Nikolaus A1 - Mautner, Karin A1 - Thiele, Jan T1 - Usage Space Analysis for Reliability Testing JF - Quality and Reliability Engineering International N2 - During the development process of a complex technical product, one widely used and important technique is accelerated testing where the applied stress on a component is chosen to exceed the reference stress, i.e. the stress encountered in field operation, in order to reduce the time to failure. For that, the reference stress has to be known. Since a complex technical product may fail regarding numerous failure modes, stress in general is highly dimensional rather than scalar. In addition, customers use their products individually, i.e. field operation should be described by a distribution rather than by one scalar stress value. In this paper, a way to span the customer usage space is shown. It allows the identification of worst case reference stress profiles in significantly reduced dimensions with minimal loss of information. The application example shows that even for a complex product like a combustion engine, stress information can be compressed significantly. With low measurement effort it turned out that only three reference stress cycles were sufficient to cover a broad range of customer stress variety. Y1 - 2010 U6 - http://dx.doi.org/10.1002/qre.1155 SN - 1099-1638 N1 - Special Issue: Business and Industrial Statistics: Developments and Industrial Practices in Quality and Reliability VL - 26 IS - 8 SP - 877 EP - 885 PB - Wiley CY - New York ER - TY - JOUR A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Mokrov, Oleg A1 - Ahmed, Essam T1 - Uni- and bi-axial deformation behavior of laser welded advanced high strength steel sheets JF - Journal of materials processing technology N2 - Bead-on-plate butt joints of 2.5 mm hot rolled DP600/DP600 and 1.2 mm cold rolled TRIP700/TRIP700 steel sheets were performed using 6 kW CO2 laser beam welding. The welding speed ranged from 1.5 to 3.0 and from 2.1 to 3.9 m/min in DP/DP and TRIP/TRIP steel weldments respectively. A top surface helium gas was used as a shielding gas at a flow rate of 20 l/min. Metallographic examinations and transverse tensile testing (DIN EN 895: 1995) were carried out to characterize the weldments. The formability of base metals and weldments were investigated by standard Erichsen test (DIN EN ISO 20482). It was found that the uniaxial plastic behavior of both DP600 and TRIP700 base metals was in agreement with Swift and modified Mecking–Kocks models respectively. In a perpendicular tensile test to the weld line, all specimens were fractured at the base metal however the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of both DP/DP and TRIP/TRIP steel weldments and the formability has been improved with the increase of the welding speed. Y1 - 2010 U6 - http://dx.doi.org/http10.1016/j.jmatprotec.2010.08.003 SN - 0924-0136 VL - 210 IS - 15 SP - 2188 EP - 2196 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Fellin, Wolfgang A1 - King, Julian A1 - Kirsch, Ansgar A1 - Oberguggenberger, Michael T1 - Uncertainty modelling and sensitivity analysis of tunnel face stability JF - Structural safety N2 - This paper proposes an approach to the choice and evaluation of engineering models with the aid of a typical application in geotechnics. An important issue in the construction of shallow tunnels, especially in weak ground conditions, is the tunnel face stability. Various theoretical and numerical models for predicting the necessary support pressure have been put forth in the literature. In this paper, we combine laboratory experiments performed at the University of Innsbruck with current methods of uncertainty and sensitivity analysis for assessing adequacy, predictive power and robustness of the models. The major issues are the handling of the twofold uncertainty of test results and of model predictions as well as the decision about what are the influential input parameters. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.strusafe.2010.06.001 SN - 0167-4730 VL - 32 IS - 6 SP - 402 EP - 410 PB - Elsevier CY - Amsterdam ER -