TY - JOUR A1 - Werkhausen, Amelie A1 - Cronin, Neil J. A1 - Albracht, Kirsten A1 - Paulsen, Gøran A1 - Larsen, Askild V. A1 - Bojsen-Møller, Jens A1 - Seynnes, Olivier R. T1 - Training-induced increase in Achilles tendon stiffness affects tendon strain pattern during running JF - PeerJ N2 - Background During the stance phase of running, the elasticity of the Achilles tendon enables the utilisation of elastic energy and allows beneficial contractile conditions for the triceps surae muscles. However, the effect of changes in tendon mechanical properties induced by chronic loading is still poorly understood. We tested the hypothesis that a training-induced increase in Achilles tendon stiffness would result in reduced tendon strain during the stance phase of running, which would reduce fascicle strains in the triceps surae muscles, particularly in the mono-articular soleus. Methods Eleven subjects were assigned to a training group performing isometric singleleg plantarflexion contractions three times per week for ten weeks, and another ten subjects formed a control group. Before and after the training period, Achilles tendon stiffness was estimated, and muscle-tendon mechanics were assessed during running at preferred speed using ultrasonography, kinematics and kinetics. Results Achilles tendon stiffness increased by 18% (P <0:01) in the training group, but the associated reduction in strain seen during isometric contractions was not statistically significant. Tendon elongation during the stance phase of running was similar after training, but tendon recoil was reduced by 30% (P <0:01), while estimated tendon force remained unchanged. Neither gastrocnemius medialis nor soleus fascicle shortening during stance was affected by training. Discussion These results show that a training-induced increase in Achilles tendon stiffness altered tendon behaviour during running. Despite training-induced changes in tendon mechanical properties and recoil behaviour, the data suggest that fascicle shortening patterns were preserved for the running speed that we examined. The asymmetrical changes in tendon strain patterns supports the notion that simple inseries models do not fully explain the mechanical output of the muscle-tendon unit during a complex task like running. KW - Achilles tendon KW - Stiffness KW - Running KW - Tendon properties KW - Architectural gear ratio Y1 - 2019 U6 - https://doi.org/10.7717/peerj.6764 SN - 21678359 PB - Peer CY - London ER - TY - BOOK A1 - Uibel, Thomas A1 - Peterson, Leif Arne ED - Uibel, Thomas ED - Peterson, Leif Arne T1 - Tagungsband Aachener Holzbautagung 2019 Y1 - 2019 SN - 2197-4489 PB - FH Aachen CY - Aachen ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Pourshahidi, Ali Mohammad A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Multiplex detection of different magnetic beads using frequency scanning in magnetic frequency mixing technique JF - Sensors N2 - In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic beads using frequency scanning in magnetic frequency mixing technique magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements. KW - frequency mixing magnetic detection KW - magnetic sandwich immunoassay KW - multiparametric immunoassays Y1 - 2019 U6 - https://doi.org/10.3390/s19112599 SN - 1424-8220 VL - 19 IS - 11 PB - MDPI CY - Basel ER - TY - CHAP A1 - Bergmann, Kevin A1 - Gräbener, Josefine A1 - Wild, Dominik A1 - Ulfers, H. A1 - Czupalla, Markus T1 - Study on thermal stabilization of a GEO-stationary telescope baffling system by integral application of phase change material T2 - International Conference on Environmental Systems N2 - The utilization of phase change material (PCM) for latent heat storage and thermal control of spacecraft has been demonstrated in the past in few missions only. One limiting factor was the fact that all concepts developed so far envisioned the PCM to be applied as an additional capacitor, encapsulated in its own housing, leading to mass, efficiency and accommodation challenges. Recently, the application of PCM within the scan cavity of a GEOS type satellite has been suggested, in order to tackle thermal issues due to direct sun intrusion (Choi, M., 2014). However, the application of PCM in such complex mechanical structures is extremely challenging. A new concept to tackle this issue is currently under development at the FH Aachen University of Applied Sciences. The concept "Infused Thermal Solutions (ITS)" is based on the idea to 3D print metallic structures in their regular functional shape, but double walled with internal lattice support structures, allowing the infusion of a PCM layer directly into the voids and eliminating the need for additional parts and interfaces. Together with OHB System, FH Aachen theoretically studied the application of this technology to the Meteosat Third Generation (MTG) Infra-Red Sounder (IRS) instrument. The study focuses on the scan cavity and entrance baffling assembly (EBA) of the IRS. It consists of thermal analyses, 3D-redesign and bread boarding of a scaled and PCM infused EBA version. In the thermal design of the alternative EBA, PCM was applied directly into the EBA, simulating the worst hot case sun intrusion of the mission. By applying 4kg of PCM (to a 60kg baffle) the EBA temperature excursions during sun intrusion were limited from 140K to 30K, leading to a significant thermo-opto-elastic performance gain. This paper introduces the ITS concept development status. Y1 - 2019 N1 - 49th International Conference on Environmental Systems, 7-11 July 2019, Boston, Massachusetts ; ICES-2019-72 SP - 1 EP - 14 ER - TY - GEN A1 - Reiswich, Martin A1 - Brandt, Hannes A1 - Czupalla, Markus T1 - Passive thermal control by integration of phase change material into additively manufactured structures T2 - E2. 47th Student conference N2 - Optical Instruments require an extremely stable thermal surrounding to prevent loss of data quality by misalignments of the instrument components resulting from material deformation due to temperature f luctuations (e.g. from solar intrusion). Phase Change Material (PCM) can be applied as a thermal damper to achieve a more uniform temperature distribution. The challenge of this method is, among others, the integration of PCM into affected areas. If correctly designed, incoming heat is latently absorbed during phase change of the PCM, i.e. the temperature of a structure remains almost constant. In a cold phase, the heat during phase change is released again latently until the PCM returns to its original state of aggregation. Thus, the structure is thermally stabilized. At FH Aachen– University of Applied Sciences research is conducted to apply PCM directly into the structures of affected components (baffles, optical benches, electronic boxes, etc.). Through the application of Additive Manufacturing, the necessary voids are directly printed into these structures and filled later with PCM. Additive Manufacturing enables complex structures that would not have been possible with conservative manufacturing methods. A corresponding Breadboard was developed and manufactured by Selective Laser Melting (SLM). The current state of research includes the handling and analysis of the Breadboard, tests and a correlation of the thermal model. The results have shown analytically and practically that it is possible to use PCM as an integral part of the structure as a thermal damper. The results serve as a basis for the further development of the technology, which should maximize performance and enable the integration of PCM into much more complex structures. Y1 - 2019 N1 - 70th International Astronautical Congress, 21. - 25. Oktober 2019, Washington D.C., United States ER - TY - GEN A1 - Biewendt, Marcel A1 - Blaschke, Florian A1 - Böhnert, Arno ED - Koponicsne Györke, Diana T1 - The rebound effect: a critical and systematic review on the current state of affairs T2 - Abstracts of the International Conference on Sustainable Economy and Agriculture Y1 - 2019 SN - 978-615-5599-72-9 N1 - International Conference on Sustainable Economy and Agriculture. Kaposvár University – Kaposvár – Hungary – 14th November 2019 SP - 101 EP - 101 PB - Universität Kaposvár CY - Kaposvár ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Neuendorf, Christian A1 - Faßbender, Tobias A1 - Nölke, Greta A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection JF - Plos One N2 - Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more than 700 ng/ml. Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0219356 SN - 1932-6203 VL - 14 IS - 7 PB - Plos CY - San Francisco ER - TY - JOUR A1 - Baringhaus, Ludwig A1 - Gaigall, Daniel T1 - On an asymptotic relative efficiency concept based on expected volumes of confidence regions JF - Statistics - A Journal of Theoretical and Applied Statistic N2 - The paper deals with an asymptotic relative efficiency concept for confidence regions of multidimensional parameters that is based on the expected volumes of the confidence regions. Under standard conditions the asymptotic relative efficiencies of confidence regions are seen to be certain powers of the ratio of the limits of the expected volumes. These limits are explicitly derived for confidence regions associated with certain plugin estimators, likelihood ratio tests and Wald tests. Under regularity conditions, the asymptotic relative efficiency of each of these procedures with respect to each one of its competitors is equal to 1. The results are applied to multivariate normal distributions and multinomial distributions in a fairly general setting. KW - Volume of confidence regions KW - asymptotic relative efficiency KW - likelihood ratio test KW - multivariate normal distribution KW - multinomial distribution Y1 - 2019 U6 - https://doi.org/10.1080/02331888.2019.1683560 SN - 1029-4910 VL - 53 IS - 6 SP - 1396 EP - 1436 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Gaigall, Daniel T1 - On a new approach to the multi-sample goodness-of-fit problem JF - Communications in Statistics - Simulation and Computation N2 - Suppose we have k samples X₁,₁,…,X₁,ₙ₁,…,Xₖ,₁,…,Xₖ,ₙₖ with different sample sizes ₙ₁,…,ₙₖ and unknown underlying distribution functions F₁,…,Fₖ as observations plus k families of distribution functions {G₁(⋅,ϑ);ϑ∈Θ},…,{Gₖ(⋅,ϑ);ϑ∈Θ}, each indexed by elements ϑ from the same parameter set Θ, we consider the new goodness-of-fit problem whether or not (F₁,…,Fₖ) belongs to the parametric family {(G₁(⋅,ϑ),…,Gₖ(⋅,ϑ));ϑ∈Θ}. New test statistics are presented and a parametric bootstrap procedure for the approximation of the unknown null distributions is discussed. Under regularity assumptions, it is proved that the approximation works asymptotically, and the limiting distributions of the test statistics in the null hypothesis case are determined. Simulation studies investigate the quality of the new approach for small and moderate sample sizes. Applications to real-data sets illustrate how the idea can be used for verifying model assumptions. KW - Goodness-of-fit test KW - Multi-sample problem KW - Parametric bootstrap Y1 - 2019 U6 - https://doi.org/10.1080/03610918.2019.1618472 SN - 1532-4141 VL - 53 IS - 10 SP - 2971 EP - 2989 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Jan Thimo, Grundmann A1 - Bauer, Waldemar A1 - Biele, Jens A1 - Boden, Ralf A1 - Ceriotti, Matteo A1 - Cordero, Federico A1 - Dachwald, Bernd A1 - Dumont, Etienne A1 - Grimm, Christian D. A1 - Hercik, David T1 - Capabilities of Gossamer-1 derived small spacecraft solar sails carrying Mascot-derived nanolanders for in-situ surveying of NEAs JF - Acta Astronautica Y1 - 2019 U6 - https://doi.org/10.1016/j.actaastro.2018.03.019 SN - 0094-5765 VL - 156 IS - 3 SP - 330 EP - 362 PB - Elsevier CY - Amsterdam ER -