TY - CHAP A1 - Fabo, Sabine ED - Schmidt, Sabine Maria T1 - REMOTEWORDS – anticipating the big observer T2 - Hacking the city : Interventionen in urbanen und kommunikativen Räumen ; Museum Folkwang, [16. Juli - 26. September 2010] KW - Streetart KW - Öffentlicher Raum KW - Stadtgestaltung KW - Aktionskunst KW - Kommunikationsguerrilla Y1 - 2011 SN - 978-3-86930-187-7 N1 - http://www.hackingthecity.org SP - 134 EP - 137 PB - Steidl ; Edition Folkwang CY - Göttingen [u.a.] ER - TY - GEN A1 - Martin, Conrad Steven A1 - Frauenrath, Tobias A1 - Zerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Evaluation of Magneto Alert Sensor (MALSE) to Improve MR Safety by Decreasing the Incidence of Ferromagnetic Projectile Accidents T2 - 2011 ISMRM Annual Meeting Proceedings N2 - The magnetic forces of fringe magnetic fields of MR systems on ferromagnetic components can impose a severe patient, occupational health and safety hazard. MRI accidents are listed as number 9 of the top 10 risks in modern medicine. With the advent of ultrahigh field MR systems including passively shielded magnet versions, this risk, commonly known as the missile or projectile effect is even more pronounced. A strategy employing magnetic field sensors which can be attached to ferromagnetic objects that are commonly used in a clinical environment is conceptually appealing for the pursuit of reducing the risk of ferromagnetic projectile accidents. Y1 - 2011 SN - 1545-4428 N1 - ISMRM 19th Annual Meeting & Exhibition, 7-13 May 2011, Montreal, Quebec, Canada ER - TY - CHAP A1 - Bragard, Michael A1 - Ronge, C. A1 - De Doncker, R. W. T1 - Sandwich design of high-power thyristor based devices with integrated MOSFET structure T2 - Proceedings of the 2011 - 14th - European Conference on Power Electronics and Applications (EPE 2011) : Aug. 30, 2011 - Sept. 1, 2011, Birmingham, United Kingdom Y1 - 2011 SN - 978-1-61284-167-0 (Print) SN - 978-90-75815-15-3 (Online) PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Bragard, Michael A1 - Gottschlich, J. A1 - De Doncker, R. W. T1 - Design and realization of a credit card size driver stage for high power thyristor based devices with integrated MOS structure T2 - 2011 IEEE 8th International Conference on Power Electronics and ECCE Asia (ICPE & ECCE 2011) : Jeju, South Korea, 30 May 2011 - 3 June 2011 / [co-sponsored by the Korean Institute of Power Electronics ...] Y1 - 2011 SN - 978-1-61284-958-4 (Print) SN - 978-1-61284-956-0 (Online) U6 - https://doi.org/10.1109/ICPE.2011.5944661 SP - 1182 EP - 1189 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - GEN A1 - Frauenrath, Tobias A1 - Dieringer, Matthias A1 - Patel, Nishant A1 - Zerdem, Celal A1 - Hentschel, Jan A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - From Artifact to Merit: Cardiac Gated MRI at 7T & 3T using Magneto-Hydrodynamic Effects for Synchronization T2 - 2011 ISMRM Annual Meeting Proceedings N2 - ECG is corrupted by magneto-hydrodynamic effects at higher magnetic field strength. Artifacts in the ECG trace and severe T-wave elevation might be mis-interpreted as R-waves. MHD being inherently sensitive to blood flow and blood velocity provides an alternative approach for cardiac gating, even in peripheral target areas far away from the commonly used upper torso positions of ECG electrodes. This feature would be very beneficial to address traveling time induced motion artifacts and trigger latency related issues raised by ECG-gated peripheral MR angiography. For all those reasons, this work proposes the use of MHD-trigger for cardiac gated MR. Y1 - 2011 SN - 1545-4428 N1 - ISMRM 19th Annual Meeting & Exhibition, 7-13 May 2011, Montreal, Quebec, Canada ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas A1 - Halbach, Bastian A1 - Hartl, Florian ED - Marca, David A. T1 - Blended shopping : interactivity and individualization T2 - Proceedings of the International Conference on e-Business : Seville, Spain, 18 - 21 July 2011 ; [... integrated in the ICETE (International Conference on e-Business and Telecommunications) joint conference] Y1 - 2011 SN - 978-989-8425-70-6 SP - 47 EP - 52 PB - SciTePress CY - [Lissabon] ER - TY - CHAP A1 - Hahn, Thomas A1 - Kelly, Svenja A1 - Muffler, Kai A1 - Tippkötter, Nils A1 - Ulber, Roland ED - Hans-Jörg, Bart ED - Pilz, Stephan T1 - Extraction of lignocellulose and algae for the production of bulk and fine chemicals T2 - Industrial scale natural products extraction Y1 - 2011 SN - 978-3-527-32504-7 (Print) SN - 978-3-527-63512-2 (Online) U6 - https://doi.org/10.1002/9783527635122 SP - 221 EP - 245 PB - Wiley-VCH CY - Weinheim ER -