TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - GEN A1 - Capitain, C. C. A1 - Lukeba, L. A1 - Ulber, Roland A1 - Tippkötter, Nils T1 - Biomimetische Klebstoffe aus Organosolv-Lignin T2 - Chemie Ingenieur Technik N2 - Aufgrund von EU-Regularien und Umweltinitiativen wächst der Markt für nachhaltige und abbaubare Klebstoffe stetig. Organosolv (OS)-Lignin ist ein kommerziell wenig ertragreicher Nebenstrom der Lignocellulose-Bioraffinerie. Durch das "Nachahmen" der Adhäsionseigenschaften mit strukturverwandten Muschel-Aminosäuren soll OS-Lignin in einen starkes, vollständig biobasiertes Adhäsiv umgewandelt werden. Funktionsweisend für die Adhäsion des Muschelklebstoffes ist die Catecholgruppe der Aminosäure L-DOPA. Die laccase-katalysierte Polymerisationsreaktion von Lignin und L-DOPA ist schwierig zu kontrollieren, da L-DOPA eine Ringschlussreaktion eingeht. Stattdessen wurde eine zweistufige Reaktion mit einem Diamin als Ankermolekül etabliert. Die Catecholgruppe, die im zweiten Schritt enzymatisch an das Lignin-Amin gebunden wird, kann durch Komplexbildung mit Fe(III)-Ionen sowohl zur Adhäsion als auch zur Kohäsion des Klebstoffes beitragen. Der Lignin-Catechol-Klebstoff ist frei von petrochemischen Chemikalien und biologisch abbaubar. In ersten Stirnzugversuchen konnte eine Haftkraft von 0,3 MPa erreicht werden. Y1 - 2018 U6 - https://doi.org/10.1002/cite.201855076 SN - 0009-286X SN - 1522-2640 (eISSN) N1 - ProcessNet-Jahrestagung und 33. DECHEMA-Jahrestagung der Biotechnologen 2018, 10. - 13. September 2018, Eurogress Aachen VL - 90 IS - 9 SP - 1167 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Gaigall, Daniel T1 - Test for Changes in the Modeled Solvency Capital Requirement of an Internal Risk Model JF - ASTIN Bulletin N2 - In the context of the Solvency II directive, the operation of an internal risk model is a possible way for risk assessment and for the determination of the solvency capital requirement of an insurance company in the European Union. A Monte Carlo procedure is customary to generate a model output. To be compliant with the directive, validation of the internal risk model is conducted on the basis of the model output. For this purpose, we suggest a new test for checking whether there is a significant change in the modeled solvency capital requirement. Asymptotic properties of the test statistic are investigated and a bootstrap approximation is justified. A simulation study investigates the performance of the test in the finite sample case and confirms the theoretical results. The internal risk model and the application of the test is illustrated in a simplified example. The method has more general usage for inference of a broad class of law-invariant and coherent risk measures on the basis of a paired sample. KW - Bootstrap KW - Empirical process KW - Functional Delta Method KW - Hadamard differentiability KW - Paired sample Y1 - 2021 U6 - https://doi.org/10.1017/asb.2021.20 SN - 1783-1350 VL - 51 IS - 3 SP - 813 EP - 837 PB - Cambridge Univ. Press CY - Cambridge ER - TY - JOUR A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry T1 - Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems JF - Energy : the international journal Y1 - 2004 U6 - https://doi.org/10.1016/S0360-5442(03)00199-3 SN - 0360-5442 N1 - SolarPACES 2002, Zürich, Switzerland, 4–6 September 2002 VL - 29 IS - 5-6 (Special Issue SolarPaces) SP - 947 EP - 959 ER - TY - RPRT A1 - Damm, Marc André A1 - Anthrakidis, Anette A1 - Fend, Thomas T1 - Partikelminderungssystem mit einstellbarem Partikelrückhaltegrad : Varytrap : Schlussbericht : Laufzeit: 01.07.2010-28.02.2014 Y1 - 2015 U6 - https://doi.org/10.2314/GBV:848651863 N1 - Report-Nr: 17012X10 CY - Jülich ER - TY - RPRT A1 - Benner, Joachim T1 - Dynamisches Verhalten drehelastischer Kupplungen unter Berücksichtigung allgemeiner Materialgleichungen und Einbeziehung von Ausfallkriterien : Literaturrecherche; Berichtszeitraum 1981 - 1982. - (Forschungsheft / Forschungsvereinigung Antriebstechnik e.V. ; 132) Y1 - 1982 PB - Forschungsvereinigung Antriebstechnik e.V. CY - Frankfurt/M. ER - TY - CHAP A1 - Fabo, Sabine T1 - Pandemische Momente T2 - Interaktion – Emotion – Desinfektion ; Kunst und Museum in Zeiten von Corona / Birgit Richard, Jana Müller, Niklas von Reischach (Hrsg.) Y1 - 2022 SN - 978-3-593-51520-5 (Print) SN - 978-3-593-44960-9 (E-Book) SP - 137 EP - 140 PB - Campus CY - Frankfurt ; New York ER - TY - BOOK A1 - Laack, Walter van T1 - Weltbilder gestern und heute – Was bleibt und worüber lacht man morgen? T3 - Vorträge & Einsichten, Lectures & Insights Y1 - 2019 SN - ISBN 978-3936624-44-1 IS - Band 2 PB - van Laack Buchverlag CY - Aachen ER - TY - GEN A1 - Tippkötter, Nils A1 - Staub, C. A1 - Sohling, U. A1 - Ruf, N. A1 - Ulber, Roland T1 - Adsorptive Aufreinigung von Molkeproteinen T2 - Chemie Ingenieur Technik N2 - In der Molkeverarbeitung dominieren Membranfiltrationsverfahren die Prozessführung. Hierbei werden üblicherweise Aufkonzentrierungen der Proteine und deren Trennung von dem Milchzucker Lactose durchgeführt. Der Prozess der adsorptiven Aufreinigung soll als kostengünstige Alternative zu den bisher gebräuchlichen Verfahren dienen. Weiterhin eröffnet sich durch das Verfahren die Möglichkeit, einzelne Proteinfraktionen während der Verarbeitung anzureichern. Als Proteinquellen wurden für die Untersuchungen Modellproteine, Lösungen aus Molkenproteinisolat, Dünnmolke und Molkekonzentrat verwendet. Die Eignung zur Proteinbindung wurden an Tonmaterialien, Silicaten und y-Aluminiumoxiden in Pulverform, in Form von Granulaten sowie Extrudaten als auch sphärischen Partikeln überprüft. Adsorbentien aus Bentonit/Silica und c-Aluminiumoxid können sowohl a-Lactalbumin (aLA) als auch b-Lactoglobulin (bLG) binden, wohingegen Materialien aus Siliciumoxid lediglich ein starkes Adsorptionsverhalten gegenüber bLG zeigen. Mischmaterialien aus Siliciumoxid und a-Aluminiumoxid zeigen dasselbe Verhalten wie Materialien aus Siliciumoxid, weisen jedoch eine geringere Kapazität auf. Die Materialen wurden hinsichtlich ihres Einsatzes in chromatographischen Verfahren und Batch-Prozessen untersucht und ein Prozessentwurf für einen zweistufigen Batch-Prozess im Rührkessel erarbeitet. KW - Molkeproteine KW - Adsorption Y1 - 2012 U6 - https://doi.org/10.1002/cite.201250395 SN - 0009-286X SN - 1522-2640 (eISSN) N1 - ProcessNet-Jahrestagung 2012 und 30. DECHEMA-Jahrestagung der Biotechnologen, 10. – 13. September 2012, Karlsruhe VL - 84 IS - 8 SP - 1285 PB - Wiley-VCH CY - Weinheim ER -