TY - JOUR A1 - Siqueira, Jose R. A1 - Molinnus, Denise A1 - Beging, Stefan A1 - Schöning, Michael Josef T1 - Incorporating a hybrid urease-carbon nanotubes sensitive nanofilm on capacitive field-effect sensors for urea detection JF - Analytical chemistry N2 - The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor’s surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance–voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform. Y1 - 2014 U6 - https://doi.org/10.1021/ac500458s SN - 1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print) VL - 86 IS - 11 SP - 5370 EP - 5375 PB - ACS Publications CY - Columbus ER - TY - JOUR A1 - Srivastava, A. A1 - Lahiri, S. A1 - Maiti, M. A1 - Knolle, F. A1 - Hoyler, Friedrich A1 - Scherer, Ulrich W. A1 - Schnug, E. W. T1 - Study of naturally occurring radioactive material (NORM) in top soil of Punjab State from the North Western part of India JF - Journal of Radioanalytical and Nuclear Chemistry Y1 - 2014 U6 - https://doi.org/0.1007/s10967-014-3450-1 SN - 1588-2780 (E-Journal); 0022-4081 (Print); 0134-0719 (Print); 0236-5731 (Print); 1417-2097 (Print) VL - 2014 IS - 302 SP - 1049 EP - 1052 PB - Springer Nature CY - Basel ER - TY - JOUR A1 - Stadler, Alexander Maximilian A1 - Garvey, Christopher J. A1 - Embs, Jan Peter A1 - Koza, Michael Marek A1 - Unruh, Tobias A1 - Artmann, Gerhard A1 - Zaccai, Guiseppe T1 - Picosecond dynamics in haemoglobin from different species: A quasielastic neutron scattering study JF - Biochimica et biophysica acta (BBA): General Subjects Y1 - 2014 U6 - https://doi.org/10.1016/j.bbagen.2014.06.007 SN - 1872-8006 (E-Journal); 0304-4165 (Print) VL - 1840 IS - 10 SP - 2989 EP - 2999 PB - Elsevier CY - Amsterdam ER - TY - GEN A1 - Stadtmüller, R. A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Produktion von einzelsträngigen DNA-Makronukleotiden T2 - Chemie Ingenieur Technik N2 - In der Biotechnologie stellt Einzelstrang-DNA (ssDNA) eine Schlüsselrolle dar und fungiert z. B. als Baustein für die nanoskalige Feinmechanik oder als Affinitätsligand, ein sog. Aptamer. Hinsichtlich der industriellen Verwendung bieten Aptamere im Vergleich zu Antikörpern viele Vorteile, wie z. B. eine gute Renaturierung bzw. die Selektion für cytotoxische Moleküle. Aktuell wächst die Nachfrage für chimäre Aptamere von bis zu 200 n, um die simultane Bindung bzw. die Modifikation mehrerer Moleküle zu realisieren. Bis heute wird ssDNA mittels einer sequentiellen Synthese hergestellt, die eine Effizienz von ca. 99,5 % je Zyklus und bereits bei einer Produktlänge von 100 n nur noc hAusbeuten von max. 60 % zeigt. Um dem Bedarf an ssDNA im Bereich > 100 n zu entsprechen, wurden zwei enzymatische Verfahren zur Produktion dieser Makronukleotide entworfen. Die erste Technik basiert auf einerFestphasen-PCR und ermöglicht sowohlein Primer- als auch ein Templatrecycling. Das zweite Verfahren beruht auf einer Plasmidbasierten In-vivo-Amplifikation, der sog. AptaGENE®-Technologie. In einer einzigen Klonierung werden bis zu 100 Kopien des Monomers in einen Vektor kloniert. Nach einer Transformation folgt der reguläre Produktionsprozess in Form einer Kultivierung, Plasmidpräparation und sequenziellen Aufarbeitung von bis zu 6 · 10¹⁵ Makronukleotiden pro Milliliter Fermentationsvolumen. Y1 - 2014 U6 - https://doi.org/10.1002/cite.201450372 SN - 0009-286X SN - 1522-2640 (eISSN) N1 - ProcessNet-Jahrestagung 2014 und 31. DECHEMA-Jahrestagung der Biotechnologen, 30. September - 2. Oktober 2014, Eurogress Aachen VL - 86 IS - 9 SP - 1403 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Stulpe, Werner T1 - From the attempt of certain classical reformulations of quantum mechanics to quasi-probability representations JF - Journal of Mathematical Physics N2 - The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered. Y1 - 2014 U6 - https://doi.org/10.1063/1.4861939 SN - 222-488 N1 - bereits unter gleichem Titel aufgenommen bei arxiv : http://arxiv.org/pdf/1307.2314.pdf VL - 55 IS - 1 PB - AIP Publishing CY - College Park, Md. ER - TY - JOUR A1 - Takenaga, Shoko A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Öhlschläger, Peter A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Toward multi-analyte bioarray sensors: LAPS-based on-chip determination of a Michaelis–Menten-like kinetics for cell culturing JF - Physica status solidi A : Applications and materials science N2 - The metabolic activity of Chinese hamster ovary (CHO) cells was observed using a light-addressable potentiometric sensor (LAPS). The dependency toward different glucose concentrations (17–200 mM) follows a Michaelis–Menten kinetics trajectory with Kₘ = 32.8 mM, and the obtained Kₘ value in this experiment was compared with that found in literature. In addition, the pH shift induced by glucose metabolism of tumor cells transfected with the HPV-16 genome (C3 cells) was successfully observed. These results indicate the possibility to determine the tumor cells metabolism with a LAPS-based measurement device. Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201330464 SN - 1521-396X (E); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1410 EP - 1415 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Theysohn, Jens M. A1 - Kraff, Oliver A1 - Eilers, Kristina A1 - Andrade, Dorian A1 - Gerwig, Marcus A1 - Timmann, Dagmar A1 - Schmitt, Franz A1 - Ladd, Mark E. A1 - Ladd, Susanne C. A1 - Bitz, Andreas T1 - Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers JF - PLoS one N2 - Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role. Y1 - 2014 U6 - https://doi.org/10.1371/journal.pone.0092104 SN - 1932-6203 VL - 9 IS - 3 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Thomas, Axel T1 - Generation Y JF - P.T. : Magazin für Wirtschaft und Gesellschaft Y1 - 2014 SN - 1860-501X VL - 10 IS - 3 SP - 6 EP - 9 PB - OPS Netzwerk CY - Leipzig ER - TY - JOUR A1 - Thomas, Axel A1 - Wassenberg, Gerd T1 - Erfolgreich sein im Kampf um die besten Talente : Employer Branding JF - Wirtschaftliche Nachrichten der Industrie- und Handelskammer Aachen Y1 - 2014 N1 - Nur noch nach Anfrage bei der IHK Aachen erhältlich: https://www.ihk.de/aachen/servicemarken/presse/medien-der-ihk/wirtschaftliche-nachrichten/aktuelle-ausgaben PB - IHK Aachen CY - Aachen ER - TY - BOOK A1 - Tietze, Jürgen T1 - Einführung in die angewandte Wirtschaftsmathematik : das praxisnahe Lehrbuch - inklusive Brückenkurs für Einsteiger. - 17. erw. Aufl. Y1 - 2014 SN - 978-3-658-02361-4 ; 978-3-658-02360-7 PB - Springer CY - Wiesbaden ET - 17., erw. Aufl. ER -