TY - JOUR A1 - Anik, Sabri A1 - Frohberg, Martin G. A1 - Kapoor, Madan Lal T1 - Experiments and theoretical considerations on the solution of oxygen in binary metal alloys JF - Berichte der Bunsengesellschaft für physikalische Chemie Y1 - 1983 SN - 0005-9021 SN - 0940-483X VL - 87 IS - 12 SP - 1201 EP - 1204 ER - TY - JOUR A1 - Heuermann, Holger A1 - Harzheim, Thomas A1 - Cronenbroeck, Tobias T1 - First SIMO harmonic radar based on the SFCW concept and the HR transfer function JF - Remote sensing N2 - This paper presents a new SIMO radar system based on a harmonic radar (HR) stepped frequency continuous wave (SFCW) architecture. Simple tags that can be electronically individually activated and deactivated via a DC control voltage were developed and combined to form an MO array field. This HR operates in the entire 2.45 GHz ISM band for transmitting the illumination signal and receives at twice the stimulus frequency and bandwidth centered around 4.9 GHz. This paper presents the development, the basic theory of a HR system for the characterization of objects placed into the propagation path in-between the radar and the reflectors (similar to a free-space measurement with a network analyzer) as well as first measurements performed by the system. Further detailed measurement series will be made available later on to other researchers to develop AI and machine learning based signal processing routines or synthetic aperture radar algorithms for imaging, object recognition, and feature extraction. For this purpose, the necessary information is published in this paper. It is explained in detail why this SIMO-HR can be an attractive solution augmenting or replacing existing systems for radar measurements in production technology for material under test measurements and as a simplified MIMO system. The novel HR transfer function, which is a basis for researchers and developers for material characterization or imaging algorithms, is introduced and metrologically verified in a well traceable coaxial setup. KW - MUT measurement; scanner KW - transponder KW - SFCW KW - harmonic radar KW - nonlinear radar Y1 - 2021 U6 - https://doi.org/10.3390/rs13245088 SN - 2072-4292 N1 - This article belongs to the Special Issue "Nonlinear Junction Detection and Harmonic Radar" VL - 13 IS - 24 PB - MDPI CY - Basel ER - TY - JOUR A1 - Horbach, Andreas A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Modelling of compressible and orthotropic surgical mesh implants based on optical deformation measurement JF - Journal of the mechanical behavior of biomedical materials Y1 - 2017 U6 - https://doi.org/10.1016/j.jmbbm.2017.06.012 SN - 1751-6161 VL - 74 SP - 400 EP - 410 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wegner, Lena A1 - von Arx, Georg A1 - Sass-Klaassen, Ute G. W. A1 - Eilmann, Britta T1 - ROXAS – an efficient and accurate tool to detect vessels in diffuse-porous species JF - IAWA Journal / International Association of Wood Anatomists Y1 - 2013 U6 - https://doi.org/10.1163/22941932-00000034 SN - 0928-1541 (Print) SN - 2294-1932 (Online) VL - 34 IS - 4 SP - 425 EP - 432 PB - Brill CY - Leiden ER - TY - JOUR A1 - Richter, Charlotte A1 - Braunstein, Bjoern A1 - Stäudle, Benjamin A1 - Attias, Julia A1 - Suess, Alexander A1 - Weber, Tobias A1 - Mileva, Katja N. A1 - Rittweger, Joern A1 - Green, David A. A1 - Albracht, Kirsten T1 - Gastrocnemius medialis contractile behavior is preserved during 30% body weight supported gait training JF - Frontiers in Sports and Active Living N2 - Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75% of the speed at which they typically transition to running, with 0% and 30% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle–tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle–tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle–series elastic element behavior. Walking with 30% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle–tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle–series elastic element behavior was observed during walking with 30% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking. KW - AlterG KW - rehabilitation KW - gait KW - walking KW - ultrasound imaging KW - series elastic element behavior KW - muscle fascicle behavior KW - unloading Y1 - 2021 U6 - https://doi.org/10.3389/fspor.2020.614559 SN - 2624-9367 VL - 2021 IS - 2 PB - Frontiers CY - Lausanne ER - TY - JOUR A1 - Bernecker, Andreas A1 - Klier, Julia A1 - Stern, Sebastian A1 - Thiel, Lea T1 - Sustaining high performance beyond public-sector pilot projects. Y1 - 2018 IS - September 2018 ER - TY - JOUR A1 - Eilmann, Britta A1 - Sterck, Frank J. A1 - Wegner, L. A1 - de Vries, Sven M. G. A1 - von Arx, G. A1 - Mohren, Godefridus M. J. A1 - den Ouden, Jan A1 - Sass-Klaassen, Ute G. W. T1 - Wood structural differences between northern and southern beech provenances growing at a moderate site JF - Tree Physiology Y1 - 2014 U6 - https://doi.org/10.1093/treephys/tpu069 SN - 1758-4469 (Online) SN - 0829-318X (Print) VL - 34 IS - 8 SP - 882 EP - 893 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues JF - Asia pacific journal on computational engineering Y1 - 2015 U6 - https://doi.org/10.1186/s40540-015-0015-x SN - 2196-1166 VL - 2 IS - 3 (December 2015) SP - 1 EP - 18 ER - TY - JOUR A1 - Droop, Philipp A1 - Chen, Shaohuang A1 - Radford, Melissa J. A1 - Paulßen, Elisabeth A1 - Gates, Byron D. A1 - Reilly, Raymond M. A1 - Radchenko, Valery A1 - Hoehr, Cornelia T1 - Synthesis of 197m/gHg labelled gold nanoparticles for targeted radionuclide therapy JF - Radiochimica Acta N2 - Meitner-Auger-electron emitters have a promising potential for targeted radionuclide therapy of cancer because of their short range and the high linear energy transfer of Meitner-Auger-electrons (MAE). One promising MAE candidate is 197m/gHg with its half-life of 23.8 h and 64.1 h, respectively, and high MAE yield. Gold nanoparticles (AuNPs) that are labelled with 197m/gHg could be a helpful tool for radiation treatment of glioblastoma multiforme when infused into the surgical cavity after resection to prevent recurrence. To produce such AuNPs, 197m/gHg was embedded into pristine AuNPs. Two different syntheses were tested starting from irradiated gold containing trace amounts of 197m/gHg. When sodium citrate was used as reducing agent, no 197m/gHg labelled AuNPs were formed, but with tannic acid, 197m/gHg labeled AuNPs were produced. The method was optimized by neutralizing the pH (pH = 7) of the Au/197m/gHg solution, which led to labelled AuNPs with a size of 12.3 ± 2.0 nm as measured by transmission electron microscopy. The labelled AuNPs had a concentration of 50 μg (gold)/mL with an activity of 151 ± 93 kBq/mL (197gHg, time corrected to the end of bombardment). KW - 197m/gHg KW - Gold nanoparticle (AuNP) KW - Meitner-Auger-electron (MAE) KW - Targeted radionuclide therapy (TRT) Y1 - 2023 U6 - https://doi.org/10.1515/ract-2023-0144 SN - 2193-3405 VL - 111 IS - 10 SP - 773 EP - 779 PB - De Gruyter CY - Berlin [u.a.] ER - TY - JOUR A1 - Feichtinger, Linda M. A1 - Eilmann, Britta A1 - Buchmann, Nina A1 - Rigling, Andreas T1 - Trait-specific responses of Scots pine to irrigation on a short vs long time scale JF - Tree Physiology Y1 - 2015 U6 - https://doi.org/10.1093/treephys/tpu114 SN - 1758-4469 (Online) SN - 0829-318X (Print) N1 - Ab 12 Monaten nach Veröffentlichung kostenfrei zugänglich. VL - 35 IS - 00 SP - 1 EP - 12 PB - Heron CY - Victoria, BC ER -