TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Digel, Ilya T1 - Primary thermosensory events in cells JF - Transient receptor potential channels / Md. Shahidul Islam, ed. Y1 - 2011 SN - 978-94-007-0264-6 N1 - (Advances in experimental medicine and biology ; 704) SP - 451 EP - 468 PB - Springer CY - Dordrecht [u.a.] ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Staat, Manfred T1 - Probabilistic limit and shakedown analysis of thin plates and shells JF - Structural safety. 31 (2009), H. 1 Y1 - 2009 SN - 0167-4730 SP - 1 EP - 18 PB - - ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Kopp, Alexander A1 - Schmeets, Ralf A1 - Gosau, Martin A1 - Friedrich, Reinhard E. A1 - Fuest, Sandra A1 - Behbahani, Mehdi A1 - Barbeck, Mike A1 - Rutkowski, Rico A1 - Burg, Simon A1 - Kluwe, Lan A1 - Henningsen, Anders T1 - Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application JF - In Vivo Y1 - 2019 U6 - http://dx.doi.org/10.21873/invivo.11536 SN - 1791-7549 VL - 33 IS - 3 SP - 757 EP - 762 ER - TY - JOUR A1 - Jiminez German, Salvador A1 - Behbahani, Mehdi A1 - Miettinen, Susanna A1 - Grijpma, Dirk W. A1 - Haimi, Suvi P. T1 - Proliferation and differentiation of adipose stem cells towards smooth muscle cells on poly(trimethylene carbonate) membranes JF - Macromolecular symposia Y1 - 2013 SN - 0258-0322 VL - Vol. 334 IS - Iss. 1 SP - 133 EP - 142 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Blome, Hans-Joachim A1 - Seboldt, Wolfgang A1 - Dachwald, Bernd A1 - Richter, Lutz T1 - Proposal for an integrated European Space Exploration Study JF - Space Debris and Space Traffic Management Symposium 2004 : proceedings of the International Academy of Astronautics Space Debris and Space Traffic Management Symposium, held in conjunction with the 55th International Astronautical Congress (IAC), October 4 - 8, 2004, Vancouver, British Columbia, Canada / ed. by Joerg Bendisch Y1 - 2004 SN - 0-87703-523-7 N1 - Proceedings IAC-2004-IAA, 3.6.1.06; Space Debris and Space Traffic Management Symposium <2004, Vancouver, British Columbia> ; International Academy of Astronautics PB - Univelt CY - San Diego, Calif. ER - TY - JOUR A1 - Digel, Ilya A1 - Zerlin, Kay A1 - Temiz Artmann, Aysegül A1 - Engels, S. T1 - Protein dynamics in thermosensation JF - Regenerative medicine. 2 (2007), H. 5 Y1 - 2007 SN - 1746-0751 N1 - Proceedings of the 3rd World Congress on Regenerative Medicine. October 18-20, 2007. Leipzig, Germany SP - 533 EP - 533 ER - TY - JOUR A1 - Hackl, Michael A1 - Müller, Lars-Peter A1 - Staat, Manfred A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian T1 - Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques JF - Knee surgery, sports traumatology, arthroscopy N2 - Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 148 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Baumann, Marcus A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Pulse wave velocity in retinal arteries of healthy volunteers JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 11 SP - 675 EP - 679 PB - BMJ Publ. Group CY - London ER -