TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI N2 - Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading. Y1 - 2010 SN - 9780429206597 (eBook) U6 - https://doi.org/10.1201/NOE0415563277-90 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Balakrishnan, Karthikeyan A1 - Andrei-Selmer, Luminita-Cornelia A1 - Selmer, Thorsten A1 - Bacher, Michael A1 - Dodel, Richard T1 - Comparison of intravenous immunoglobulins for naturally occurring autoantibodies against amyloid-β JF - Journal of Alzheimer's Disease N2 - Intravenous immunoglobulins (IVIG) are currently used for therapeutic purposes in autoimmune disorders. Recently, we demonstrated the presence of naturally occurring antibodies against amyloid- β (nAbs-Aβ) within the pool of IVIG. In this study, we compared different brands of IVIG for nAbs-Aβ and have found differences in the specificity of the nAbs-Aβ towards Aβ1–40 and Aβ1–42 . We analyzed the influence of a pH-shift over the course of antibody storage using ELISA and investigated antibody dimerization at acidic and neutral pH as well as differences in the IgG subclass distributions among the IVIG using both HPLC and a nephelometric assay. Furthermore, we investigated the epitope region of purified nAbs-Aβ. The differences found in Aβ specificity are not directly proportionate to the binding nature of these antibodies when administered in vivo. This information, however, may serve as a guide when choosing the commercial source of IVIG for therapeutic applications in Alzheimer's disease Y1 - 2010 U6 - https://doi.org/10.3233/JAD-2010-1353 SN - 1387-2877 VL - 20 IS - 1 SP - 135 EP - 143 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard T1 - Solar tower power plant in Germany and future perspectives of the development of the technology in Greece and Cyprus JF - Renewable Energy N2 - Since the 80s power production with solar thermal power plants has been a way to substitute fossil fuels. By concentrating direct solar radiation from heliostats very high temperatures of a thermal fluid can be reached. The resulting heat is converted to mechanical energy in a steam cycle which generates electricity. High efficiencies and fast start-up are reached by using air as a heat medium, as well as using porous ceramic materials as solar receiver of the concentrated sunlight. In Germany the construction of a 1.5 MWe solar tower power plant began in 2008. It is operational since December 2008 and started production of electricity in the spring of 2009. In Greece and Cyprus, countries with high solar potential, the development of this competitive solar thermal technology is imperative, since it has already been implemented in other Mediterranean countries. Y1 - 2010 U6 - https://doi.org/10.1016/j.renene.2009.11.003 SN - 0960-1481 VL - 35 IS - 7 SP - 1352 EP - 1356 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Baumann, Torsten A1 - Teixeira Boura, Cristiano José A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard A1 - O'Connell, Bryan A1 - Schmitz, Stefan A1 - Zunft, Stefan T1 - Air/Sand heat exchanger design and materials for solar thermal power plant applications T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 146 EP - 147 PB - Soc. OSC CY - Saint Maur ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - MRS Online Proceedings Library N2 - Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too. Y1 - 2010 SN - 1946-4274 VL - 1203 PB - MRS CY - Warrendale ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical N2 - Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the “Bonn-Risk-Index” method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance–voltage and constant–capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.12.012 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 374 EP - 379 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A) N2 - A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983304 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 913 EP - 918 PB - Wiley-VCH CY - Berlin ER -