TY - JOUR A1 - Trapp, Svenja A1 - Lammers, Tom A1 - Engudar, Gokce A1 - Hoehr, Cornelia A1 - Denkova, Antonia G. A1 - Paulßen, Elisabeth A1 - de Kruijff, Robin M. T1 - Membrane-based microfluidic solvent extraction of Ga-68 from aqueous Zn solutions: towards an automated cyclotron production loop JF - EJNMMI Radiopharmacy and Chemistry KW - Microfluidic solvent extraction KW - Ga-68 KW - Cyclotron production KW - Medical radionuclide production KW - Metal contaminants Y1 - 2023 U6 - https://doi.org/10.1186/s41181-023-00195-2 SN - 2365-421X VL - 2023 IS - 8, Article number: 9 SP - 1 EP - 14 PB - Springer Nature ER - TY - JOUR A1 - Cheenakula, Dheeraja A1 - Griebel, Kai A1 - Montag, David A1 - Grömping, Markus ED - Huang, Xiaowu T1 - Concept development of a mainstream deammonification and comparison with conventional process in terms of energy, performance and economical construction perspectives JF - Frontiers in Microbiology N2 - Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8–20°C), pH (6–9) and COD:N ratio (1–6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case. KW - anammox KW - energy efficiency KW - mainstream deammonification KW - nitrogen elimination KW - wastewater Y1 - 2023 U6 - https://doi.org/10.3389/fmicb.2023.1155235 SN - 1664-302X VL - 14 IS - 11155235 SP - 1 EP - 15 PB - Frontiers ER - TY - JOUR A1 - Kempt, Hendrik A1 - Freyer, Nils A1 - Nagel, Saskia K. T1 - Justice and the normative standards of explainability in healthcare JF - Philosophy & Technology N2 - Providing healthcare services frequently involves cognitively demanding tasks, including diagnoses and analyses as well as complex decisions about treatments and therapy. From a global perspective, ethically significant inequalities exist between regions where the expert knowledge required for these tasks is scarce or abundant. One possible strategy to diminish such inequalities and increase healthcare opportunities in expert-scarce settings is to provide healthcare solutions involving digital technologies that do not necessarily require the presence of a human expert, e.g., in the form of artificial intelligent decision-support systems (AI-DSS). Such algorithmic decision-making, however, is mostly developed in resource- and expert-abundant settings to support healthcare experts in their work. As a practical consequence, the normative standards and requirements for such algorithmic decision-making in healthcare require the technology to be at least as explainable as the decisions made by the experts themselves. The goal of providing healthcare in settings where resources and expertise are scarce might come with a normative pull to lower the normative standards of using digital technologies in order to provide at least some healthcare in the first place. We scrutinize this tendency to lower standards in particular settings from a normative perspective, distinguish between different types of absolute and relative, local and global standards of explainability, and conclude by defending an ambitious and practicable standard of local relative explainability. KW - Clinical decision support systems KW - Justice KW - Medical AI KW - Explainability KW - Normative standards Y1 - 2022 U6 - https://doi.org/10.1007/s13347-022-00598-0 VL - 35 IS - Article number: 100 SP - 1 EP - 19 PB - Springer Nature CY - Berlin ER - TY - CHAP A1 - Freyer, Nils A1 - Thewes, Dustin A1 - Meinecke, Matthias ED - Gusikhin, Oleg ED - Hammoudi, Slimane ED - Cuzzocrea, Alfredo T1 - GUIDO: a hybrid approach to guideline discovery & ordering from natural language texts T2 - Proceedings of the 12th International Conference on Data Science, Technology and Applications DATA - Volume 1 N2 - Extracting workflow nets from textual descriptions can be used to simplify guidelines or formalize textual descriptions of formal processes like business processes and algorithms. The task of manually extracting processes, however, requires domain expertise and effort. While automatic process model extraction is desirable, annotating texts with formalized process models is expensive. Therefore, there are only a few machine-learning-based extraction approaches. Rule-based approaches, in turn, require domain specificity to work well and can rarely distinguish relevant and irrelevant information in textual descriptions. In this paper, we present GUIDO, a hybrid approach to the process model extraction task that first, classifies sentences regarding their relevance to the process model, using a BERT-based sentence classifier, and second, extracts a process model from the sentences classified as relevant, using dependency parsing. The presented approach achieves significantly better resul ts than a pure rule-based approach. GUIDO achieves an average behavioral similarity score of 0.93. Still, in comparison to purely machine-learning-based approaches, the annotation costs stay low. KW - Natural Language Processing KW - Text Mining KW - Process Model Extraction KW - Business Process Intelligence Y1 - 2023 SN - 978-989-758-664-4 U6 - https://doi.org/10.5220/0012084400003541 SN - 2184-285X N1 - 12th International Conference on Data Science, Technology and Applications, July 11-13, 2023, in Rome, Italy. SP - 335 EP - 342 ER - TY - CHAP A1 - Klöser, Lars A1 - Büsgen, André A1 - Kohl, Philipp A1 - Kraft, Bodo A1 - Zündorf, Albert ED - Conte, Donatello ED - Fred, Ana ED - Gusikhin, Oleg ED - Sansone, Carlo T1 - Explaining relation classification models with semantic extents T2 - Deep Learning Theory and Applications N2 - In recent years, the development of large pretrained language models, such as BERT and GPT, significantly improved information extraction systems on various tasks, including relation classification. State-of-the-art systems are highly accurate on scientific benchmarks. A lack of explainability is currently a complicating factor in many real-world applications. Comprehensible systems are necessary to prevent biased, counterintuitive, or harmful decisions. We introduce semantic extents, a concept to analyze decision patterns for the relation classification task. Semantic extents are the most influential parts of texts concerning classification decisions. Our definition allows similar procedures to determine semantic extents for humans and models. We provide an annotation tool and a software framework to determine semantic extents for humans and models conveniently and reproducibly. Comparing both reveals that models tend to learn shortcut patterns from data. These patterns are hard to detect with current interpretability methods, such as input reductions. Our approach can help detect and eliminate spurious decision patterns during model development. Semantic extents can increase the reliability and security of natural language processing systems. Semantic extents are an essential step in enabling applications in critical areas like healthcare or finance. Moreover, our work opens new research directions for developing methods to explain deep learning models. KW - Relation classification KW - Natural language processing KW - Natural language understanding KW - Information extraction KW - Trustworthy artificial intelligence Y1 - 2023 SN - 978-3-031-39058-6 (Print) SN - 978-3-031-39059-3 (Online) U6 - https://doi.org/10.1007/978-3-031-39059-3_13 N1 - 4th International Conference, DeLTA 2023, Rome, Italy, July 13–14, 2023. SP - 189 EP - 208 PB - Springer CY - Cham ER - TY - INPR A1 - Greiner, Lasse A1 - Jeromin, Günter Erich A1 - Sithole, Patience A1 - Petersen, Soenke T1 - Preprint: Studies on the enzymatic reduction of levulinic acid using Chiralidon-R and Chiralidon-S T2 - ChemRxiv N2 - The enzymatic reduction of levulinic acid by the chiral catalysts Chiralidon-R and Chiralidon-S which are commercially available superabsorbed alcohol dehydrogenases is described. The Chiralidon®-R/S reduces the levulinic acid to the (R,S)-4-hydroxy valeric acid and the (R)- or (S)- gamma-valerolactone. KW - Levulinic acid KW - Chiralidon-R KW - Chiralidon-S KW - 4-hydroxy valeric acid KW - (R)- or (S)- gamma-valerolactone Y1 - 2023 U6 - https://doi.org/10.26434/chemrxiv-2023-jlvcv ER - TY - JOUR A1 - Kuchler, Timon A1 - Günthner, Roman A1 - Ribeiro, Andrea A1 - Hausinger, Renate A1 - Streese, Lukas A1 - Wöhnl, Anna A1 - Kesseler, Veronika A1 - Negele, Johanna A1 - Assali, Tarek A1 - Carbajo-Lozoya, Javier A1 - Lech, Maciej A1 - Adorjan, Kristina A1 - Stubbe, Hans Christian A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Haller, Berhard A1 - Heemann, Uwe A1 - Schmaderer, Christoph T1 - Persistent endothelial dysfunction in post-COVID-19 syndrome and its associations with symptom severity and chronic inflammation N2 - Background Post-COVID-19 syndrome (PCS) is a lingering disease with ongoing symptoms such as fatigue and cognitive impairment resulting in a high impact on the daily life of patients. Understanding the pathophysiology of PCS is a public health priority, as it still poses a diagnostic and treatment challenge for physicians. Methods In this prospective observational cohort study, we analyzed the retinal microcirculation using Retinal Vessel Analysis (RVA) in a cohort of patients with PCS and compared it to an age- and gender-matched healthy cohort (n = 41, matched out of n = 204). Measurements and main results PCS patients exhibit persistent endothelial dysfunction (ED), as indicated by significantly lower venular flicker-induced dilation (vFID; 3.42% ± 1.77% vs. 4.64% ± 2.59%; p = 0.02), narrower central retinal artery equivalent (CRAE; 178.1 [167.5–190.2] vs. 189.1 [179.4–197.2], p = 0.01) and lower arteriolar-venular ratio (AVR; (0.84 [0.8–0.9] vs. 0.88 [0.8–0.9], p = 0.007). When combining AVR and vFID, predicted scores reached good ability to discriminate groups (area under the curve: 0.75). Higher PCS severity scores correlated with lower AVR (R = − 0.37 p = 0.017). The association of microvascular changes with PCS severity were amplified in PCS patients exhibiting higher levels of inflammatory parameters. Conclusion Our results demonstrate that prolonged endothelial dysfunction is a hallmark of PCS, and impairments of the microcirculation seem to explain ongoing symptoms in patients. As potential therapies for PCS emerge, RVA parameters may become relevant as clinical biomarkers for diagnosis and therapy management. KW - Endothelial dysfunction KW - Long COVID KW - Post-COVID-19 syndrome KW - retinal microvasculature Y1 - 2023 U6 - https://doi.org/10.1007/s10456-023-09885-6 N1 - Corresponding author: Christoph Schmaderer VL - 26 SP - 547 EP - 563 PB - Springer Nature CY - Dordrecht ER - TY - JOUR A1 - Cheng, Chi-Tsun A1 - Wollert, Jörg A1 - Chen, Xi A1 - Fapojuwo, Abraham O. T1 - Guest Editorial : Circuits and Systems for Industry X.0 Applications JF - IEEE Journal on Emerging and Selected Topics in Circuits and Systems Y1 - 2023 U6 - https://doi.org/10.1109/JETCAS.2023.3278843 SN - 2156-3357 (Print) SN - 2156-3365 (Online) VL - 13 SP - 457 EP - 460 PB - IEEE CY - New York ET - 2 ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Pourshahidi, Ali Mohammad A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Multiplex detection of different magnetic beads using frequency scanning in magnetic frequency mixing technique JF - Sensors N2 - In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic beads using frequency scanning in magnetic frequency mixing technique magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements. KW - frequency mixing magnetic detection KW - magnetic sandwich immunoassay KW - multiparametric immunoassays Y1 - 2019 U6 - https://doi.org/10.3390/s19112599 SN - 1424-8220 VL - 19 IS - 11 PB - MDPI CY - Basel ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Tödter, Julia A1 - Niehues, Julia A1 - Telöken, Matthias A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - 3D printed modular immunofiltration columns for frequency mixing-based multiplex magnetic immunodetection JF - Sensors N2 - For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated. Y1 - 2019 U6 - https://doi.org/10.3390/s19010148 SN - 1424-8220 VL - 19 IS - 1 PB - MDPI CY - Basel ER -