TY - CHAP A1 - Ferrein, Alexander A1 - Scholl, Ingrid A1 - Neumann, Tobias A1 - Krückel, Kai A1 - Schiffer, Stefan T1 - A system for continuous underground site mapping and exploration Y1 - 2019 U6 - https://doi.org/10.5772/intechopen.85859 ER - TY - JOUR A1 - Claer, Mario A1 - Ferrein, Alexander A1 - Schiffer, Stefan T1 - Calibration of a Rotating or Revolving Platform with a LiDAR Sensor JF - Applied Sciences Y1 - 2019 U6 - https://doi.org/10.3390/app9112238 SN - 2076-3417 VL - Volume 9 IS - issue 11, 2238 PB - MDPI CY - Basel ER - TY - CHAP A1 - Ritz, Thomas A1 - Strauch, Jakob ED - Back, Andrea T1 - Strukturierte Ermittlung beeinflussender Faktoren für mobile Softwarelösungen T2 - MMS 2012 : mobile und ubiquitäre Informationssysteme ; 7. Konferenz zur "Mobile und Ubiquitäre Informationssysteme" ; 01 - 02. März 2012 in Braunschweig, Germany. - (GI-Edition lecture notes in informatics ; 202) Y1 - 2012 SN - 978-3-88579-296-3 (CD-ROM-Ausg.) PB - Ges. für Informatik CY - Bonn ER - TY - JOUR A1 - Kahmann, Stephanie L. A1 - Rausch, Valentin A1 - Plümer, Jonathan A1 - Müller, Lars P. A1 - Pieper, Martin A1 - Wegmann, Kilian T1 - The automized fracture edge detection and generation of three-dimensional fracture probability heat maps JF - Medical Engineering & Physics N2 - With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map. We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1–2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature. Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further. KW - Fracture classification KW - Shoulder KW - Probability distribution mapping KW - Morphing KW - Imaging Y1 - 2022 SN - 1350-4533 VL - 2022 IS - 110 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Engelmann, Ulrich M. A1 - Simsek, Beril A1 - Shalaby, Ahmed A1 - Krause, Hans-Joachim T1 - Key contributors to signal generation in frequency mixing magnetic detection (FMMD): an in silico study JF - Sensors N2 - Frequency mixing magnetic detection (FMMD) is a sensitive and selective technique to detect magnetic nanoparticles (MNPs) serving as probes for binding biological targets. Its principle relies on the nonlinear magnetic relaxation dynamics of a particle ensemble interacting with a dual frequency external magnetic field. In order to increase its sensitivity, lower its limit of detection and overall improve its applicability in biosensing, matching combinations of external field parameters and internal particle properties are being sought to advance FMMD. In this study, we systematically probe the aforementioned interaction with coupled Néel–Brownian dynamic relaxation simulations to examine how key MNP properties as well as applied field parameters affect the frequency mixing signal generation. It is found that the core size of MNPs dominates their nonlinear magnetic response, with the strongest contributions from the largest particles. The drive field amplitude dominates the shape of the field-dependent response, whereas effective anisotropy and hydrodynamic size of the particles only weakly influence the signal generation in FMMD. For tailoring the MNP properties and parameters of the setup towards optimal FMMD signal generation, our findings suggest choosing large particles of core sizes dc > 25 nm nm with narrow size distributions (σ < 0.1) to minimize the required drive field amplitude. This allows potential improvements of FMMD as a stand-alone application, as well as advances in magnetic particle imaging, hyperthermia and magnetic immunoassays. KW - key performance indicators KW - magnetic biosensing KW - coupled Néel–Brownian relaxation dynamics KW - frequency mixing magnetic detection KW - magnetic relaxation KW - micromagnetic simulation KW - magnetic nanoparticles Y1 - 2024 U6 - https://doi.org/10.3390/s24061945 SN - 1424-8220 N1 - This article belongs to the Special Issue "Advances in Magnetic Sensors and Their Applications" VL - 24 IS - 6 PB - MDPI CY - Basel ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred T1 - Optical strain measurement for the modeling of surgical meshes and their porosity JF - Current Directions in Biomedical Engineering N2 - The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes. Y1 - 2018 U6 - https://doi.org/10.1515/cdbme-2018-0045 SN - 2364-5504 VL - Band 4 IS - 1 SP - 181 EP - 184 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Ernhardt, Selina A1 - Drumm, Christian A1 - van Gog, Tamara A1 - Brand-Gruwel, Saskia A1 - Jarodzka, Halszka T1 - Through the eyes of a programmer : a research project on how to foster programming education with eye-tracking technology T2 - Tagungsband zur 32. AKWI-Jahrestagung vom 15.09.2019 bis 18.09.2019 an der Fachhochschule für Angewandte Wissenschaften Aachen Y1 - 2019 SN - 978-3-944330-62-4 SP - 42 EP - 47 PB - Mana-Buch CY - Heide ER - TY - CHAP A1 - Kroll-Ludwigs, Kathrin ED - Weller, Marc-Philippe ED - Kindler, Peter T1 - Art. 48 EGBGB: Wahl eines in einem anderen Mitgliedstaat der Europäischen Union erworbenen Namens, Rn. 5-8, Rn. 11-14, Rn. 45-47, Rn. 48-51 T2 - Beck‘scher Online-Großkommentar zum Bürgerlichen Recht (BeckOGK), Band: Internationales Privatrecht Y1 - 2017 PB - C.H.Beck CY - München ER - TY - CHAP A1 - Sattler, Johannes Christoph A1 - Schneider, Iesse Peer A1 - Angele, Florian A1 - Atti, Vikrama Naga Babu A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Development of heliostat field calibration methods: Theory and experimental test results T2 - SolarPACES 2022 conference proceedings N2 - In this work, three patent pending calibration methods for heliostat fields of central receiver systems (CRS) developed by the Solar-Institut Jülich (SIJ) of the FH Aachen University of Applied Sciences are presented. The calibration methods can either operate in a combined mode or in stand-alone mode. The first calibration method, method A, foresees that a camera matrix is placed into the receiver plane where it is subjected to concentrated solar irradiance during a measurement process. The second calibration method, method B, uses an unmanned aerial vehicle (UAV) such as a quadrocopter to automatically fly into the reflected solar irradiance cross-section of one or more heliostats (two variants of method B were tested). The third calibration method, method C, foresees a stereo central camera or multiple stereo cameras installed e.g. on the solar tower whereby the orientations of the heliostats are calculated from the location detection of spherical red markers attached to the heliostats. The most accurate method is method A which has a mean accuracy of 0.17 mrad. The mean accuracy of method B variant 1 is 1.36 mrad and of variant 2 is 1.73 mrad. Method C has a mean accuracy of 15.07 mrad. For method B there is great potential regarding improving the measurement accuracy. For method C the collected data was not sufficient for determining whether or not there is potential for improving the accuracy. KW - Heliostat Field Calibration KW - Unmanned aerial vehicle KW - UAV KW - Quadrocopter KW - Camera system Y1 - 2024 U6 - https://doi.org/10.52825/solarpaces.v1i.678 SN - 2751-9899 (online) N1 - SolarPACES 2022: 28th International Conference on Concentrating Solar Power and Chemical Energy Systems, 27-30 September, Albuquerque, NM, USA IS - 1 PB - TIB Open Publishing CY - Hannover ER - TY - THES A1 - Tran, Hui Ming T1 - Das Haus des Meeres : Entwicklung und Konzeption eines neuen Erscheinungsbildes für den Aqua Terra Zoo N2 - Im Zentrum von Wien befindet sich in einem ehemaligen Flakturm aus dem 2. Weltkrieg, das Haus des Meeres. Auf ca 5000m2 beherbergen sie ca. 10.000 Tiere. Der Fokus liegt dabei auf die Unterwasserwelt und bietet einen ausgiebigen Einblick in die Welt der Meere. Das neue Erscheinungsbild positioniert die private und gemeinnützige Einrichtung sowohl als Ort des Zusammenkommens als auch der Wissensvermittlung. Dabei soll das Designkonzept vor dem Betreten des Zoos seine besondere Baukonstruktion aufzeigen und von Anfang an die Tiefe sowie Tiefenzonen der Meere einbeziehen. Damit distanzieren sie sich entscheidend von ähnlichen Institutionen. Inspiriert von der Teilung zwischen der Oberfläche und dem Meer, entstand eine feine abstrakte Skala. Diese visualisiert den Meeresspiegel mit seiner Tiefe und dient medienübergreifend als Orientierungshilfe. KW - Corporate Design KW - Ozean KW - Zoo KW - Meere KW - Erscheinungsbild Y1 - 2023 N1 - Für diese Arbeit steht kein Volltext zur Verfügung. PB - FH Aachen CY - Aachen ER -