TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. T1 - Quo Vadis - Ausblick in die Gebäudeleittechnik der Zukunft T1 - Whitherfacility management? An outlook to the future JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerstände bei der Durchdringung des Marktes. N2 - Producers and planners of facility management systems are still faced with building owners' reluctance, especially when it comes to private homes. Y1 - 2005 SN - 1436-5103 VL - 56 IS - 1 SP - 39 EP - 41 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. A1 - Groß, H. T1 - Gebäudeautomation - Betriebsdatenerfassung und Gebäudeleittechnik im Klartext T1 - Operating data- and facility management in clear JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 2003 SN - 1436-5103 VL - 54 IS - 2 SP - 81 PB - Springer CY - Düsseldorf ER - TY - THES A1 - Groß, Rolf Fritz T1 - Zur Kinetik homogener Gasphasenreaktionen nitroser Komponenten in Rauchgasen einer kohlebefeuerten Wirbelschicht KW - Kohlefeuerung KW - Wirbelschichtfeuerung KW - Stickstoffoxide KW - Reduktion KW - Rohrreaktor Y1 - 2002 SN - 3-8322-0004-5 (softcover) SN - 3-8322-0004-6 (elektronisch) N1 - Dissertation RWTH Aachen PB - Shaker CY - Aachen ER - TY - RPRT A1 - Christ, Ansgar A1 - Groß, Rolf Fritz A1 - Renz, Ulrich T1 - HGR: Untersuchung zur Minimierung von gasförmigen Schadstoffen aus Rauchgasen bei der Heißgasfiltration T1 - Hot gas filtration: investigations to remove gaseous pollutant components out of flue gas during hot gas filtration N2 - Gas- und Dampfturbinen-Kraftwerke mit Druckwirbelschicht- oder mit Druckvergasungsverfahren ermöglichen die Verstromung von Kohle mit hohem Wirkungsgrad und niedrigen Emissionen. Eine Voraussetzung für den Betrieb dieser Anlagen ist die Entstaubung der Rauchgase bei hohen Temperaturen und Drücken. Abreinigungsfilter mit keramischen Elementen werden dazu eingesetzt. Eine Reduzierung gasförmiger Schadstoffe unter den gleichen Bedingungen könnte Rauchgaswäsche ersetzen. Ziel des Gesamtvorhabens ist es, die Integration von Heißgasfiltration und katalytischem Abbau der Schadstoffe Kohlenmonoxid, Kohlenwasserstoffe und Stickoxide in einen Verfahrensschritt zu untersuchen. Die Arbeitsschwerpunkte dieses Teilvorhabens betreffen: die katalytische Wirkung eisenhaltiger Braunkohlenaschen, die Wirksamkeit des Calciumaluminat als Katalysator des Abbaus unverbrannter Kohlenwasserstoffe im Heißgasfilter, numerische Simulation der kombinierten Abscheidung von Partikeln und gasförmigen Schadstoffen aus Rauchgasen N2 - Power plants with gas and steam turbines in pressurized fluidized bed or pressurized gasification processes enable power generation of coal with high efficiancy and little emissions. To run these plants the cleaning of the flue gas is necessary before entering the turbines under the conditions of high temperature and pressure. Ceramic filter elements are the most probable method for hot gas cleaning. A simultaneous reduction of gaseous pollutant components under these conditions could help to make the whole process more efficiant. The aim of the project is to integrate the catalytic reduction of carbon monoxide, hydrocarbons and nitric oxides into the hot gas filtration with ceramic filter elements as a one step mecanism. The project is focused on: the catalytic behaviour of ferrugious ashes of brown coal, the effectiveness of calcinated aluminates as a catalyst to remove uncombuste hydrocarbons in a hot gas filtration unit, numerical simulation of the combined removal of particels and gaseous pollutant components out of the flue gas. KW - Kraftwerkstechnik KW - Stickstoffoxide KW - Kohlenmonoxidbelastung KW - Schadgas KW - Heterogene Katalyse Y1 - 1998 U6 - https://doi.org/10.2314/GBV:504318411 N1 - Verbundprojekt im Rahmen der Projektträgerschaft BEO des BMBF der Partner RWTH Aachen, Lehrstuhl für Wärmeübertragung und Klimatechnik uve Institut für Technische Chemie und Umweltschutz GmbH, Berlin-Adlershof Hugo Petersen, Gesellschaft für verfahrenstechnischen Anlagenbau mbH&Co.KG, Wiesbaden Förderkennzeichen: 0326819F [Abschlußdatum des Vorhabens: Dezember 1997] ER - TY - JOUR A1 - Cheenakula, Dheeraja A1 - Paulsen, Svea A1 - Ott, Fabian A1 - Grömping, Markus T1 - Operational window of a deammonifying sludge for mainstream application in a municipal wastewater treatment plant JF - Water and Environment Journal N2 - The present work aimed to study the mainstream feasibility of the deammonifying sludge of side stream of municipal wastewater treatment plant (MWWTP) in Kaster, Germany. For this purpose, the deammonifying sludge available at the side stream was investigated for nitrogen (N) removal with respect to the operational factors temperature (15–30°C), pH value (6.0–8.0) and chemical oxygen demand (COD)/N ratio (≤1.5–6.0). The highest and lowest N-removal rates of 0.13 and 0.045 kg/(m³ d) are achieved at 30 and 15°C, respectively. Different conditions of pH and COD/N ratios in the SBRs of Partial nitritation/anammox (PN/A) significantly influenced both the metabolic processes and associated N-removal rates. The scientific insights gained from the current work signifies the possibility of mainstream PN/A at WWTPs. The current study forms a solid basis of operational window for the upcoming semi-technical trails to be conducted prior to the full-scale mainstream PN/A at WWTP Kaster and WWTPs globally. KW - Anammox KW - Mainstream KW - Nitrogen removal KW - Partial nitritation KW - Wastewater Y1 - 2023 U6 - https://doi.org/10.1111/wej.12898 SN - 1747-6593 N1 - Corresponding author: Dheeraja Cheenakula VL - 38 IS - 1 SP - 59 EP - 70 PB - Wiley CY - Chichester ER - TY - JOUR A1 - Cheenakula, Dheeraja A1 - Griebel, Kai A1 - Montag, David A1 - Grömping, Markus ED - Huang, Xiaowu T1 - Concept development of a mainstream deammonification and comparison with conventional process in terms of energy, performance and economical construction perspectives JF - Frontiers in Microbiology N2 - Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8–20°C), pH (6–9) and COD:N ratio (1–6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case. KW - anammox KW - energy efficiency KW - mainstream deammonification KW - nitrogen elimination KW - wastewater Y1 - 2023 U6 - https://doi.org/10.3389/fmicb.2023.1155235 SN - 1664-302X VL - 14 IS - 11155235 SP - 1 EP - 15 PB - Frontiers ER - TY - JOUR A1 - Peterson-Oster, Madeleine A1 - Peterson, Leif Arne T1 - Fassadensystem: Optisch ansprechend, freistehend, elementiert und aus Eichenholz JF - Bauen mit Holz, Der Zimmermann N2 - Bei der Entwicklung des Fassadensystems ging es darum die mögliche Dauerhaftigkeit von Holz bei direkter Bewitterung zu maximieren. Gleichzeitig soll gezeigt werden, dass mittels durchdachter Ansätze beim konstruktiven Holzschutz und die Wahl einer geeigneten Holzart langlebige Konstruktionen realisiert werden können. Y1 - 2020 SN - 0005-6545 PB - Rudolf Müller CY - Köln ER - TY - JOUR A1 - Lepke, Dietrich A1 - Lillie, Dirk A1 - Peterson, Leif Arne A1 - Hempe, Thomas T1 - Liegedauer von Holzschwellen in Tunneln der Hamburger Hochbahn AG JF - EI - Der Eisenbahningenieur N2 - Die Hamburger Hochbahn AG benötigte im Rahmen der Überarbeitung einer langfristigen Instandhaltungs- und Erneuerungsstrategie für ihre U-Bahn-Infrastruktur eine belastbare Aussage über die Restlebensdauer der Holzschwellen im Tunnel. Aus diesem Grunde beauftragte sie das Institut für Verkehrswesen, Eisenbahnbau und -betrieb (IVE) der Universität Hannover mit der Erstellung eines entsprechenden Gutachtens. Das Ergebnis führte zu der gesicherten Aussage einer erheblich längeren Restlebensdauer der Tunnelschwellen gegenüber den bisherigen, geschätzten Annahmen. Y1 - 2006 SN - 0013-2810 IS - 2 SP - 46 EP - 50 PB - DVV Media Group CY - Hamburg ER - TY - THES A1 - Peterson, Leif Arne T1 - Zum Tragverhalten nachgiebig verbundener Biegeträger aus Holz N2 - In der vorliegenden Dissertation werden zunächst die linear elastischen Bemessungsmöglichkeiten für nachgiebig verbundene Biegeträger unter statischer und dynamischer Beanspruchung diskutiert. Zum Vergleich wurden praktische Untersuchungen an zweiteiligen Kantholzbiegeträgem mit mechanischen Verbindungsmitteln unterschiedlicher Verformungscharakteristika durchgeführt, ebenso wie umfangreiche Materialprüfungen an den zusammengefügten Einzelquerschnitten. Hierdurch werden die Unterschiede zum realen, nicht elastischen, statischen Tragverhalten aufgezeigt. Der für das dynamische Verhalten maßgebende Systemparameter der Eigenfrequenz wird für mehrteilige Biegeträger theoretisch hinterfragt und an den nachgiebig verbundenen Kantholzbiegeträgem gemessen. Begleitet von weiteren praktischen Untersuchungen an einzelnen Verbindungsmitteln unter Blockscherbeanspruchung wird die rechnerische Berücksichtigung des plastischen Verbindungsmittelverhaltens auf zwei theoretischen Wegen erforscht. Auf Grundlage der Untersuchungen wird ein neues, semianalytisches y-Verfahren entwickelt. Gegenüber den Berechnungen mit finiten Volumen- und Kontakt-Elementen erweist sich das neue Verfahren auf Basis der, um die schubweichen Fugen erweiterten, Balkentheorie als leistungsfähiger. Der Einfluss des plastischen Verbindungsmittelverhaltens wird durch vergleichende Parameterstudien mit diesem neuen Verfahren als vom anerkannten Stand der Technik ausreichend berücksichtigt identifiziert. Für die linear elastische Dimensionierung werden optimierte Verbindungsmittelanordnungen hergeleitet, die durch übersichtliche Ergänzungen zum existierenden Bemessungskonzept des y-Verfahrens eine exaktere Berechnung ermöglichen. Y1 - 2008 SN - 9783816775973 N1 - Berichte des Instituts für Bauphysik, Band 1 PB - Fraunhofer IRB Verlag CY - Stuttgart ER - TY - JOUR A1 - Nabil, F. A1 - Peterson, Leif Arne A1 - Schmidt, A. A1 - Geerdes, D. T1 - Die Holzkuppel des Neuen Palais in Potsdam JF - Bauingenieur Y1 - 2010 SN - 0005-6650 VL - 85 IS - 8 SP - 324 EP - 330 PB - Springer-VDI-Verlag CY - Düsseldorf ER -