TY - JOUR A1 - Umutlu, Lale A1 - Bitz, Andreas A1 - Maderwald, Stefan A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Kraff, Oliver A1 - Brote, Irina A1 - Ladd, Susanne C. A1 - Schroeder, Tobias A1 - Forsting, Michael T1 - Contrast-enhanced ultra-high-field liver MRI: a feasibility trial JF - European Journal of Radiology Y1 - 2013 U6 - http://dx.doi.org/10.1016/j.ejrad.2011.07.004 SN - 0720-048X VL - 82 IS - 5 SP - 760 EP - 767 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Umutlu, Lale A1 - Kraff, Oliver A1 - Fischer, Anja A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Nassenstein, Kai A1 - Nensa, Felix A1 - Grüneisen, Johannes A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Forsting, Michael A1 - Ladd, Mark E. A1 - Lauenstein, Thomas C. T1 - Seven-Tesla MRI of the female pelvis JF - European Radiology Y1 - 2013 U6 - http://dx.doi.org/10.1007/s00330-013-2868-0 SN - 1432-1084 VL - 23 IS - 9 SP - 2364 EP - 2373 PB - Springer CY - Berlin ER - TY - JOUR A1 - Umutlu, Lale A1 - Orzada, Stephan A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Bronte, Irina A1 - Bitz, Andreas A1 - Kraff, Oliver A1 - Ladd, Susanne C. A1 - Antoch, Gerald A1 - Ladd, Mark E. A1 - Quick, Harald H. A1 - Lauenstein, Thomas C. T1 - Renal imaging at 7 Tesla: preliminary results JF - European Radiology N2 - Objective To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil. Methods In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists. Results Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers. Conclusion The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value. Y1 - 2011 SN - 1432-1084 VL - 21 IS - 4 SP - 841 EP - 849 PB - Springer CY - Berlin ER - TY - CHAP A1 - Usai, Pierpaolo A1 - Corucci, Alessandro A1 - Gligorevic, Snjezana A1 - Monorchio, Agostino T1 - Estimation of airport surface propagation channel: ray tracing model and measurements T2 - Proceedings of the 5th European Conference on Antennas and Propagation (EUCAP) : 11 - 15 April 2011, Rome, Italy Y1 - 2011 SN - 978-1-4577-0250-1 SP - 1634 EP - 1638 ER - TY - CHAP A1 - Viehmann, Tarik A1 - Limpert, Nicolas A1 - Hofmann, Till A1 - Henning, Mike A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard ED - Eguchi, Amy ED - Lau, Nuno ED - Paetzel-Prüsmann, Maike ED - Wanichanon, Thanapat T1 - Winning the RoboCup logistics league with visual servoing and centralized goal reasoning T2 - RoboCup 2022 N2 - The RoboCup Logistics League (RCLL) is a robotics competition in a production logistics scenario in the context of a Smart Factory. In the competition, a team of three robots needs to assemble products to fulfill various orders that are requested online during the game. This year, the Carologistics team was able to win the competition with a new approach to multi-agent coordination as well as significant changes to the robot’s perception unit and a pragmatic network setup using the cellular network instead of WiFi. In this paper, we describe the major components of our approach with a focus on the changes compared to the last physical competition in 2019. Y1 - 2023 SN - 978-3-031-28468-7 (Print) SN - 978-3-031-28469-4 (Online) U6 - http://dx.doi.org/https://doi.org/10.1007/978-3-031-28469-4_25 N1 - Robot World Cup, RoboCup 2022. 17. July 2023. Bangkok, Thailand. Part of the Lecture Notes in Computer Science book series (LNAI,volume 13561) SP - 300 EP - 312 PB - Springer CY - Cham ER - TY - JOUR A1 - Vorst, Phillip A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - AllemaniACs3D team description Y1 - 2006 SP - 1 EP - 6 ER - TY - JOUR A1 - Vos, E. K. A1 - Lagemaat, M. W. A1 - Barentsz, J. O. A1 - Fütterer, J. J. A1 - Zamecnik, P. A1 - Roozen, H. A1 - Orzada, S. A1 - Bitz, Andreas A1 - Maas, M. C. A1 - Scheenen, T. W. J. T1 - Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla JF - European Radiology N2 - Objectives To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T). Materials & methods Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff’s alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology. Results T2w imaging at 7T was achievable with ‘satisfactory’ (3/5) to ‘good’ (4/5) quality. Visibility of anatomical structures was predominantly scored as ‘satisfactory’ (3/5) and ‘good’ (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff’s analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T. Conclusion T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil. Y1 - 2014 U6 - http://dx.doi.org/10.1007/s00330-014-3234-6 SN - 1432-1084 VL - 24 IS - 8 SP - 1950 EP - 1958 PB - Springer CY - Cham ER - TY - CHAP A1 - Walenta, Robert A1 - Schellekens, Twan A1 - Ferrein, Alexander A1 - Schiffer, Stefan T1 - A decentralised system approach for controlling AGVs with ROS T2 - AFRICON, Proceedings Y1 - 2017 SN - 978-1-5386-2775-4 U6 - http://dx.doi.org/10.1109/AFRCON.2017.8095693 SN - 2153-0033 N1 - AFRICON <2017, 18-20 Sept., Cape Town, South Africa> SP - 1436 EP - 1441 PB - IEEE ER - TY - CHAP A1 - Walter, Michael A1 - Gligorevic, Snjezana A1 - Detert, Thorben A1 - Schnell, Michael T1 - UHF/VHF air-to-air propagation measurements T2 - Proceedings of the Fourth European Conference on Antennas and Propagation (EuCAP) : 12 - 16 April 2010, Barcelona, Spain Y1 - 2010 SN - 978-1-4244-6431-9 ; 978-84-7653-472-4 SP - 1 EP - 5 ER - TY - CHAP A1 - Walter, Peter A1 - Elsen, Ingo A1 - Müller, Holger A1 - Kraiss, Karl-Friedrich T1 - 3D object recognition with a specialized mixtures of experts architecture T2 - IJCNN'99. International Joint Conference on Neural Networks. Proceedings N2 - Aim of the AXON2 project (Adaptive Expert System for Object Recogniton using Neuml Networks) is the development of an object recognition system (ORS) capable of recognizing isolated 3d objects from arbitrary views. Commonly, classification is based on a single feature extracted from the original image. Here we present an architecture adapted from the Mixtures of Eaqerts algorithm which uses multiple neuml networks to integmte different features. During tmining each neural network specializes in a subset of objects or object views appropriate to the properties of the corresponding feature space. In recognition mode the system dynamically chooses the most relevant features and combines them with maximum eficiency. The remaining less relevant features arz not computed and do therefore not decelerate the-recognition process. Thus, the algorithm is well suited for ml-time applications. Y1 - 1999 SN - 0-7803-5529-6 U6 - http://dx.doi.org/10.1109/IJCNN.1999.836243 SN - 1098-7576 N1 - Washington, DC 10-16.07.1999 SP - 3563 EP - 3568 PB - IEEE CY - New York ER -