TY - JOUR A1 - Kowalewski, Paul A1 - Bragard, Michael A1 - Hüning, Felix A1 - De Doncker, Rik W. T1 - An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives JF - IEEE Transactions on Instrumentation and Measurement N2 - This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth. KW - Rotary encoder KW - Wiegand sensor Y1 - 2023 U6 - http://dx.doi.org/10.1109/TIM.2023.3326166 SN - 0018-9456 (Print) SN - 1557-9662 (Online) N1 - Early Access SP - 10 Seiten PB - IEEE ER - TY - JOUR A1 - Kobus, Thiele A1 - Bitz, Andreas A1 - Uden, Mark J. van A1 - Lagemaat, Miram W. A1 - Rothgang, Eva A1 - Orzada, Stephan A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility JF - Magnetic Resonance in Medicine N2 - 31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Y1 - 2012 U6 - http://dx.doi.org/10.1002/mrm.24175 SN - 1522-2594 VL - 68 IS - 6 SP - 1683 EP - 1695 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Klomp, D. W. J. A1 - Bitz, Andreas A1 - Heerschap, A. A1 - Scheenen, T. W. J. T1 - Proton spectroscopic imaging of the human prostate at 7 T JF - NMR in Biomedicine Y1 - 2009 U6 - http://dx.doi.org/10.1002/nbm.1360 SN - 1099-1492 VL - 22 IS - 5 SP - 495 EP - 501 ER - TY - JOUR A1 - Klinge, Uwe A1 - Wilke, Ralf A1 - Mühl, Thomas T1 - Auswahl der Herniennetze nach der “effektiven Porosität” - warum das Gewicht weniger wichtig ist JF - Chirurgische Allgemeine : CHAZ ; Zeitung für Klinik und Praxis Y1 - 2012 SN - 1615-5378 VL - 13 IS - 12 SP - 297 EP - 301 PB - Kaden CY - Mannheim ER - TY - JOUR A1 - Klinge, Uwe A1 - Otto, Jens A1 - Mühl, Thomas T1 - High Structural Stability of Textile Implants Prevents Pore Collapse and Preserves Effective Porosity at Strain JF - BioMed Research International Y1 - 2015 U6 - http://dx.doi.org/10.1155/2015/953209 SN - 2314-6133 (Print) SN - 2314-6141 (Online) N1 - Article ID: 953209 VL - 2015 ER - TY - CHAP A1 - Kirsch, Maximilian A1 - Mataré, Victor A1 - Ferrein, Alexander A1 - Schiffer, Stefan T1 - Integrating golog++ and ROS for Practical and Portable High-level Control T2 - 12th International Conference on Agents and Artificial Intelligence Y1 - 2020 U6 - http://dx.doi.org/10.5220/0008984406920699 ER - TY - CHAP A1 - Kallweit, Stephan A1 - Ferrein, Alexander A1 - Scholl, Ingrid A1 - Reichert, Walter T1 - Mobile Autonome Systeme in der Lehre, am Beispiel der ROS Summer School T2 - Tagungsband AALE 2014 : das Forum für Fachleute der Automatisierungstechnik aus Hochschulen und Wirtschaft ; 11. Fachkonferenz, Regensburg ; [11. Konferenz für Angewandte Automatisierungstechnik in Lehre und Entwicklung / Ostbayerische Technische Hochschule Regensburg; VFAALE, Verein der Freunde und Förderer der Angewandten Automatisierungstechnik] Y1 - 2014 SN - 978-3-8356-7142-3 N1 - Die Textverteilung der elektronischen Zweitveröffentlichung entspricht nicht der der o.g. Verlagsausgabe. SP - 157 EP - 163 PB - Dt. Industrieverl. CY - München ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - http://dx.doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - RPRT A1 - Jaekel, C. A1 - Klein, C. A1 - Barth, R. A1 - Roskos, H. A1 - Kyas, G. A1 - Schroeer, M. A1 - Hüning, Felix T1 - Dynamik von Nichtgleichgewichtszustaenden in Hochtemperatursupraleitern Abschlussbericht N2 - Im Projekt wurden mit Hilfe zeitaufgeloester optischer Messtechniken Relaxations-Dynamiken von optisch angeregten Ladungstraegern und Hochfrequenzeigenschaften von Hochtemperatursupraleitern untersucht. Oberhalb der Sprungtemperatur wurden die Elektron-Phonon-Kopplungskonstanten fuer YBCO und BSCCO bestimmt. Dabei wurde erstmalig ein direkter Zusammenhang zwischen der Sprungtemperatur und der Kopplungstaerke gefunden. Der Kopplungsmechanismus enthaelt sowohl phononische als auch elektronische (spindynamische) Anteile. Unterhalb von T_c wird die Dynamik durch Aufbrechen und Rekombination von Cooper-Paaren bestimmt. Bei den Arbeiten zu den kohaerenten Phononen wurde ein Modell entwickelt, das das 'Anwerfen' der Phononen und das Amplitudenverhalten unterhalb der Sprungtemperatur erklaert. Als begleitende Untersuchungen wurden breitbandige Hochfrequenz-Messungen vorgenommen. Die Methode erlaubt die Untersuchung von Ladungstraegerdichten und von Streumechanismen. Erstmalig wurde in verspannten YBCO-Duennfilmen eine starke temperaturabhaengige Resonanz-Absorption beobachtet, die als Josephson-Plasmaresonanz an intrinsischen Kontakten identifiziert werden konnte. Die Nutzbarkeit dieser Kontakte fuer Bauelemente wurde durch einen Mikrowellendetektor demonstriert. Durch den Nachweis von emittierter gepulster Strahlung aus einer stromdurchflossenen supraleitenden Bruecke nach optischer Anregung wurde erstmals die Einsatzmoeglichkeit von HTSL fuer schnelle optische Schalter demonstriert. Es wurde gezeigt, dass die Schaltgeschwindigkeit eine direkte Folge der Ladungstraegerdynamik ist. T2 - Dynamics of non-equilibrium states in HTSC. Final report KW - Relaxation KW - Phonons KW - Calcium oxides KW - Electron-phonon coupling Y1 - 1996 N1 - Foerderkennzeichen BMBF 13N6288; TRN: DE97FD184 ER - TY - CHAP A1 - Ibanez-Sanchez, Gema A1 - Wolf, Martin T1 - Interactive Process Mining-Induced Change Management Methodology for Healthcare T2 - Interactive Process Mining in Healthcare N2 - The adoption of the Digital Health Transformation is a tremendous paradigm change in health organizations, which is not a trivial process in reality. For that reason, in this chapter, it is proposed a methodology with the objective to generate a changing culture in healthcare organisations. Such a change culture is essential for the successful implementation of any supporting methods like Interactive Process Mining. It needs to incorporate (mostly) new ways of team-based and evidence-based approaches for solving structural problems in a digital healthcare environment. KW - Methodology KW - Change culture KW - Lean thinking KW - Interactive process mining KW - Objective data Y1 - 2020 SN - 978-3-030-53993-1 (Online) SN - 978-3-030-53992-4 (Print) U6 - http://dx.doi.org/10.1007/978-3-030-53993-1_16 SP - 267 EP - 293 PB - Springer CY - Cham ER -