TY - BOOK A1 - Gunnar, Auth A1 - Barton, Thomas A1 - Beigel, Stefan A1 - Bensberg, Frank A1 - Brehm, Lars A1 - Wolf, Martin R. ED - Barton, Thomas ED - Herrmann, Frank ED - Meister, Vera G. ED - Müller, Christian ED - Seel, Christian T1 - Prozesse, Technologie, Anwendungen, Systeme und Management 2017 BT - Angewandte Forschung in der Wirtschaftsinformatik. Tagungsband zur 30. AKWI-Jahrestagung vom 17.09.2017 bis 20.09.2017 an der Hochschule Aschaffenburg / Arbeitskreis Wirtschaftsinformatik an Fachhochschulen (AKWI) Y1 - 2017 SN - 978-3-944330-56-3 PB - Mana-Buch CY - Heide ER - TY - CHAP A1 - Losse, Ann-Kathrin A1 - Gehrke, Melanie A1 - Ullrich, André A1 - Czarnecki, Christian A1 - Sultanow, Eldar A1 - Breithaupt, Carsten A1 - Koch, Christian T1 - Entwicklung einer Open-Data-Referenzarchitektur für die Luftfahrtindustrie T2 - INFORMATIK 2022 - Informatik in den Naturwissenschaften, Proceedings N2 - Open Data impliziert die freie Zugänglichkeit, Verfügbarkeit und Wiederverwendbarkeit von Datensätzen. Obwohl hochwertige Datensätze öffentlich verfügbar sind, ist der Zugang zu diesen und die Transparenz über die Formate nicht immer gegeben. Dies mindert die optimale Nutzung des Potenzials zur Wertschöpfung, trotz der vorherrschenden Einigkeit über ihre Chancen. Denn Open Data ermöglicht das Vorantreiben von Compliance-Themen wie Transparenz und Rechenschaftspflicht bis hin zur Förderung von Innovationen. Die Nutzung von Open Data erfordert Mut und eine gemeinsame Anstrengung verschiedener Akteure und Branchen. Im Rahmen des vorliegenden Beitrags werden auf Grundlage des Design Science-Ansatzes eine Open Data Capability Map sowie darauf aufbauend eine Datenarchitektur für Open Data in der Luftfahrtindustrie an einem Beispiel entwickelt. Y1 - 2022 SN - 978-3-88579-720-3 U6 - https://doi.org/10.18420/inf2022_103 SN - 1617-5468 N1 - INFORMATIK 2022, 26. - 30. September 2022, Hamburg SP - 1203 EP - 1209 PB - GI - Gesellschaft für Informatik CY - Bonn ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - PAT A1 - Bragard, Michael A1 - Hüning, Felix A1 - Kowalewski, Paul T1 - Vorrichtung zur Relativlagenbestimmung [Offenlegungschrift] N2 - Die Erfindung betrifft eine Vorrichtung zur Bestimmung einer Relativlage zwischen einem feststehenden Teil und einem zu demselben in eine Bewegungsrichtung bewegbaren beweglichen Teil, wobei der feststehende Teil mit einem Wiegandsensor versehen ist, wobei der Wiegandsensor zwischen zwei gegenpolig zueinander ausgebildeten Permanentmagneten angeordnet ist und dass der bewegliche Teil eine Mehrzahl von beabstandet zueinander angeordneten Magnetisierungsstegen aus einem magnetisch leitenden Material aufweist, die in der Bewegungsrichtung zumindest eine gleich große Erstreckung aufweisen wie der Permanentmagnet, dass ein Abstand zwischen benachbarten Magnetisierungsstegen derart gewählt ist, dass in einer ersten Relativlage ein erster Permanentmagnet von einem der Magnetisierungsstege überdeckt ist und ein zweiter Permanentmagnet nicht von einem der Magnetisierungsstege überdeckt ist. Y1 - 2023 N1 - Offenlegungschrift zu DE102022115350A1 2023.12.21 ER - TY - CHAP A1 - Penne, Jochen A1 - Profittlich, Martin A1 - Ringbeck, Thorsten A1 - Buxbaum, Bernd ED - D, Nicola D'Apuzzo T1 - Touchless detailed 3D scan of human hand anatomy using time-of-flight cameras T2 - Proceedings of the International Conference on 3D Body Scanning Technologies : Lugano, Switzerland, 19-20 October 2010 Y1 - 2010 SN - 978-3-033-02714-5 SP - 361 EP - 369 PB - Hometrica Consulting CY - Zürich ER - TY - RPRT A1 - Leßenich, Nina A1 - Ritz, Thomas A1 - Wallenborn, Ramona T1 - Prototyping zur Verbesserung der Benutzerfreundlichkeit mobiler Software : Potenziale benutzerfreundlicher Software-Entwicklung ; Info-Broschüre N2 - Mobile Anwendungen nehmen mit der Verbreitung von Smartphones zu. Die Akzeptanz der Nutzer bestimmt den Erfolg solcher mobiler Applikationen dabei maßgeblich. Um diese Anerkennung zu schaffen, ist eine möglichst hohe Gebrauchstauglichkeit, auch Usability genannt, notwendig. Die Informationsbroschüre „Prototyping zur Verbesserung der Benutzerfreundlichkeit mobiler Software“ richtet sich an Personen, die an der Gestaltung und entwicklung von (mobiler) Software beteiligt sind. In dieser Broschüre werden mögliche Potenziale im Bereich einer effizienten und benutzerzentrierten Software-Entwicklung aufgezeigt. Y1 - 2014 PB - eBusiness-Lotse CY - Aachen ER - TY - PAT A1 - Hilgenstock, Jörg A1 - Lange, Robert A1 - Riedel, Helmut A1 - Ringbeck, Thorsten T1 - Verfahren und Entfernungsmessvorrichtung zum Bestimmen der Entfernung zwischen einem Objekt und der Vorrichtung : [Offenlegungsschrift / Europäische Patentanmeldung] T1 - Method and distance measuring device for determining the distance between an object and the device Y1 - 2006 PB - Deutsches Patent- und Markenamt / Europäisches Patentamt CY - München / Den Hague ER - TY - JOUR A1 - Ritz, Thomas A1 - Pisarczyk, Rafael A1 - Sachtleben, Johanna A1 - Leßenich, Nina T1 - Usability Engineering maßgeschneidert : Modellbaukasten zur Entwicklung gebrauchstauglicher mobiler Software JF - Wissenschaft trifft Praxis Y1 - 2014 SN - 2198-8544 (Print) SN - 2198-9362 (Online) N1 - Der Link führt zum vollständigen Heft, der Artikel beginnt auf S.79. VL - 1 IS - 1 SP - 79 EP - 88 PB - Begleitforschung Mittelstand-Digital c/o WIK-Consult GmbH CY - Bad Honnef ER - TY - JOUR A1 - Wallenborn, Ramona A1 - Ritz, Thomas T1 - Mobilität miteinander teilen : städtisches eCarsharing in einer vernetzten Gesellschaft ; [vernetztes Fahren von morgen] JF - Neue Mobilität : das Magazin vom Bundesverband eMobilität Y1 - 2014 SN - 2191-5636 VL - 5 IS - 14 (Herbstausg.) SP - 92 EP - 95 PB - Bundesverband eMobilität BEM CY - Berlin ER -