TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - GEN A1 - Tkachenko, Valeriy A1 - von Knobelsdorff-Brenkenhoff, Florian A1 - Kleindienst, Denise A1 - Winter, Lukas A1 - Rieger, Jan A1 - Frauenrath, Tobias A1 - Dieringer, Matthias A. A1 - Santoro, Davide A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiovasular MR at 7Tesla: assessment of the right ventricle T2 - 2012 ISMRM Annual Meeting Proceedings N2 - The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - CHAP A1 - Lenz, Laura L. A1 - Wolf, Martin R. ED - Kritz, Willy Christian T1 - Economic evaluation of serious games with the comparative assessment framework COSEGA T2 - The shift from teaching to learning : individual, collective and organizational learning through gaming simulation ; proceedings of the 45th conference of the International Simulation and Gaming Association, Dornbirn 2014 Y1 - 2014 SN - 978-3-7639-5422-3 SP - 374 EP - 386 PB - Bertelsmann CY - [Bielefeld] ER - TY - GEN A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Hoffmann, Werner A1 - Kellmann, Peter A1 - Martin, Conrad A1 - Niendorf, Thoralf T1 - Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T T2 - 2012 ISMRM Annual Meeting Proceedings N2 - Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - JOUR A1 - Schulte-Tigges, Joschua A1 - Förster, Marco A1 - Nikolovski, Gjorgji A1 - Reke, Michael A1 - Ferrein, Alexander A1 - Kaszner, Daniel A1 - Matheis, Dominik A1 - Walter, Thomas T1 - Benchmarking of various LiDAR sensors for use in self-driving vehicles in real-world environments JF - Sensors N2 - Abstract In this paper, we report on our benchmark results of the LiDAR sensors Livox Horizon, Robosense M1, Blickfeld Cube, Blickfeld Cube Range, Velodyne Velarray H800, and Innoviz Pro. The idea was to test the sensors in different typical scenarios that were defined with real-world use cases in mind, in order to find a sensor that meet the requirements of self-driving vehicles. For this, we defined static and dynamic benchmark scenarios. In the static scenarios, both LiDAR and the detection target do not move during the measurement. In dynamic scenarios, the LiDAR sensor was mounted on the vehicle which was driving toward the detection target. We tested all mentioned LiDAR sensors in both scenarios, show the results regarding the detection accuracy of the targets, and discuss their usefulness for deployment in self-driving cars. KW - Lidar KW - Benchmark KW - Self-driving Y1 - 2022 U6 - https://doi.org/10.3390/s22197146 SN - 1424-8220 N1 - This article belongs to the Special Issue "Sensor Fusion for Vehicles Navigation and Robotic Systems" VL - 22 IS - 19 PB - MDPI CY - Basel ER - TY - CHAP A1 - Ritz, Thomas A1 - Izquierdo Tello, César A1 - Damm, Sebastian T1 - Connecting a pedelec to the cloud as basis for gamification in multi modal mobility planning T2 - MobileCloud 2014 : 2nd IEEE International Conference on Mobile Cloud Computing, Services, and Engineering Oxford, United Kingdom 7-10 April 2014 Y1 - 2014 SN - 978-1-4799-2504-9 U6 - https://doi.org/10.1109/MobileCloud.2014.25 SP - 101 EP - 108 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Dieringer, Matthias A. A1 - Özerdem, Celal A1 - Patel, Nishan A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Elgeti, Thomas A1 - Niendorf, Thoralf T1 - Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study JF - Journal of Magnetic Resonance Imaging N2 - Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc. Y1 - 2012 U6 - https://doi.org/10.1002/jmri.23634 SN - 1522-2586 VL - 36 IS - 2 SP - 364 EP - 372 PB - Wiley-Liss CY - New York ER - TY - PAT A1 - Hüning, Felix A1 - Backes, Andreas T1 - Wiegand-Modul N2 - Ein Wiegand-Modul (110;210;310) umfassend- eine Sensorspule (112;212;312),- einen ersten Wiegand-Draht (116a;216a;316a), der zumindest teilweise innerhalb der Sensorspule (112;212;312) angeordnet ist, und- einen zweiten Wiegand-Draht (116b;216b;316b), der zumindest teilweise innerhalb der Sensorspule (112;212;312) angeordnet ist und sich im Wesentlichen parallel zu dem ersten Wiegand-Draht (116a;216a;316a) erstreckt, ist bekannt.Um eine effiziente Ausnutzung der durch die Ummagnetisierung der Wiegand-Drähte (116a,116b;216a,216b;316a,316b) in die Sensorspule (112;212;312) induzierten elektrischen Energie zu ermöglichen, sind der erste Wiegand-Draht (116a;216a;316a) und der zweite Wiegand-Draht (116b;216b;316b) bezogen auf eine axiale Richtung der Sensorspule (112;212;312) versetzt zueinander angeordnet. Y1 - 2023 N1 - Patent DE102021115745B3 2022.07.21 ER - TY - CHAP A1 - Wittig, M. A1 - Rütters, René A1 - Bragard, Michael ED - Reiff-Stephan, Jörg ED - Jäkel, Jens ED - Schwarz, André T1 - Application of RL in control systems using the example of a rotatory inverted pendulum T2 - Tagungsband AALE 2024 : Fit für die Zukunft: praktische Lösungen für die industrielle Automation N2 - In this paper, the use of reinforcement learning (RL) in control systems is investigated using a rotatory inverted pendulum as an example. The control behavior of an RL controller is compared to that of traditional LQR and MPC controllers. This is done by evaluating their behavior under optimal conditions, their disturbance behavior, their robustness and their development process. All the investigated controllers are developed using MATLAB and the Simulink simulation environment and later deployed to a real pendulum model powered by a Raspberry Pi. The RL algorithm used is Proximal Policy Optimization (PPO). The LQR controller exhibits an easy development process, an average to good control behavior and average to good robustness. A linear MPC controller could show excellent results under optimal operating conditions. However, when subjected to disturbances or deviations from the equilibrium point, it showed poor performance and sometimes instable behavior. Employing a nonlinear MPC Controller in real time was not possible due to the high computational effort involved. The RL controller exhibits by far the most versatile and robust control behavior. When operated in the simulation environment, it achieved a high control accuracy. When employed in the real system, however, it only shows average accuracy and a significantly greater performance loss compared to the simulation than the traditional controllers. With MATLAB, it is not yet possible to directly post-train the RL controller on the Raspberry Pi, which is an obstacle to the practical application of RL in a prototyping or teaching setting. Nevertheless, RL in general proves to be a flexible and powerful control method, which is well suited for complex or nonlinear systems where traditional controllers struggle. KW - Rotatory Inverted Pendulum KW - MPC KW - LQR KW - PPO KW - Reinforcement Learning Y1 - 2024 SN - 978-3-910103-02-3 U6 - https://doi.org/10.33968/2024.53 N1 - 20. AALE-Konferenz. Bielefeld, 06.03.-08.03.2024. (Tagungsband unter https://doi.org/10.33968/2024.29) SP - 241 EP - 248 PB - le-tex publishing services GmbH CY - Leipzig ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER -