TY - JOUR A1 - Guo, Yuanyuan A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Device simulation of the light-addressable potentiometric sensor for the investigation of the spatial resolution JF - Sensors and actuators B: Chemical N2 - As a semiconductor-based electrochemical sensor, the light-addressable potentiometric sensor (LAPS) can realize two dimensional visualization of (bio-)chemical reactions at the sensor surface addressed by localized illumination. Thanks to this imaging capability, various applications in biochemical and biomedical fields are expected, for which the spatial resolution is critically significant. In this study, therefore, the spatial resolution of the LAPS was investigated in detail based on the device simulation. By calculating the spatiotemporal change of the distributions of electrons and holes inside the semiconductor layer in response to a modulated illumination, the photocurrent response as well as the spatial resolution was obtained as a function of various parameters such as the thickness of the Si substrate, the doping concentration, the wavelength and the intensity of illumination. The simulation results verified that both thinning the semiconductor substrate and increasing the doping concentration could improve the spatial resolution, which were in good agreement with known experimental results and theoretical analysis. More importantly, new findings of interests were also obtained. As for the dependence on the wavelength of illumination, it was found that the known dependence was not always the case. When the Si substrate was thick, a longer wavelength resulted in a higher spatial resolution which was known by experiments. When the Si substrate was thin, however, a longer wavelength of light resulted in a lower spatial resolution. This finding was explained as an effect of raised concentration of carriers, which reduced the thickness of the space charge region. The device simulation was found to be helpful to understand the relationship between the spatial resolution and device parameters, to understand the physics behind it, and to optimize the device structure and measurement conditions for realizing higher performance of chemical imaging systems. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.snb.2014.08.016 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 204 SP - 659 EP - 665 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Khaydukova, M. M. A1 - Zadorozhnaya, O. A. A1 - Kirsanov, D. O. A1 - Iken, Heiko A1 - Rolka, David A1 - Schöning, Michael Josef A1 - Babain, V. A. A1 - Vlasov, Yu. G. A1 - Legin, A. V. T1 - Multivariate processing of atomic-force microscopy images for detection of the response of plasticized polymeric membranes JF - Russian journal of applied chemistry N2 - The possibility of using the atomic-force microscopy as a method for detection of the analytical signal from plasticized polymeric sensor membranes was analyzed. The surfaces of cadmium-selective membranes based on two polymeric matrices were examined. The digital images were processed with multivariate image analysis techniques. A correlation was found between the surface profile of an ion-selective membrane and the concentration of the ion in solution. Y1 - 2014 U6 - http://dx.doi.org/10.1134/S1070427214030112 SN - 1608-3296 (E-Journal); 1070-4272 (Print) VL - 87 IS - 3 SP - 307 EP - 314 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Stresses produced by different textile mesh implants in a tissue equivalent JF - BioNanoMaterials N2 - Two single-incision mini-slings used for treating urinary incontinence in women are compared with respect to the stresses they produce in their surrounding tissue. In an earlier paper we experimentally observed that these implants produce considerably different stress distributions in a muscle tissue equivalent. Here we perform 2D finite element analyses to compare the shear stresses and normal stresses in the tissue equivalent for the two meshes and to investigate their failure behavior. The results clearly show that the Gynecare TVT fails for increasing loads in a zipper-like manner because it gradually debonds from the surrounding tissue. Contrary to that, the tissue at the ends of the DynaMesh-SIS direct may rupture but only at higher loads. The simulation results are in good agreement with the experimental observations thus the computational model helps to interpret the experimental results and provides a tool for qualitative evaluation of mesh implants. Y1 - 2014 U6 - http://dx.doi.org/10.1515/bnm-2014-0003 SN - 2191-4672 (E-Journal); 2193-066X (E-Journal); 0011-8656 (Print); 1616-0177 (Print); 2193-0651 (Print) VL - 15 IS - 1-2 SP - 25 EP - 30 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Multi-Parametererfassung mit siliziumbasiertem Sensorchip: Aus Drei mach Eins JF - GIT Labor-Fachzeitschrift Y1 - 2014 SN - 0016-3538 IS - 2 SP - 28 EP - 30 PB - Wiley ER - TY - JOUR A1 - Laack, Walter van T1 - Nahtoderfahrungen aus medizinischer Sicht JF - Deutsche medizinische Wochenschrift : DMW N2 - Nah- versus Nachtoderfahrungen Nahtoderfahrungen (NTE) sind ein Phänomen aus der Kategorie „außergewöhnliche Bewusstseinserfahrungen“. Sie treten in unmittelbarer Nähe des eigenen Todes auf. Oft, aber nicht immer, handelt es sich dabei um Erfahrungen von Personen, die durch ärztliche Maßnahmen wiederbelebt wurden und später davon berichten (NTE-ler). Jedoch kommen solche Phänomene auch bei Menschen vor, die während einer schweren Erkrankung eine lebensbedrohliche Krise haben, hiervon aber spontan genesen. Den NTE ähnlich sind auch sogenannte Nachtod-erfahrungen sowie spontane Erlebnisse, die im Rahmen anderer außergewöhnlicher Stresssituationen auftreten. Von Nachtoderfahrungen spricht man, wenn die Betroffenen anlässlich des Todes von geliebten Angehörigen oder Freunden Erlebnisse haben, die inhaltlich ebenfalls, zumindest aber teilweise, denen von NTE entsprechen. Nachtoderfahrungen sowie spontane NTE-ähnliche Erlebnisse unterscheiden sich jedoch von den echten NTE zumeist sowohl quantitativ als auch qualitativ. Unter einem quantitativen Unterschied versteht man in diesem Zusammenhang eine in der Regel geringer ausgeprägte Komplexität, als sie sehr vielen NTE zu eigen ist. Da sich aber auch viele NTE selbst bezüglich ihrer Komplexität unterscheiden, ist der Hauptunterschied qualitativer Natur: Echte NTE besitzen gegenüber den anderen hier erwähnten Phänomenen eine größere inhaltliche und emotionale Tiefe. Sie begleiten die Betroffenen anschließend ein Leben lang – zumeist mit positiven, in Einzelfällen aber auch mit negativen Folgen, die bis zu einem späteren Suizid reichen können. Die genannten außergewöhnlichen Bewusstseinsphänomene lassen sich in ihrer Gesamtheit bei rund 5 % der Bevölkerung finden. NTE im Speziellen haben hiervon einen durchaus bedeutenden Anteil. Je nach Studie geben zwischen 18 % und 40 % aller Personen, die reanimiert wurden, an, währenddessen eine NTE erlebt zu haben. Dass nicht alle eine solche Erfahrung machen, wird von Kritikern gern dahingehend interpretiert, NTE seien rein physiologischer und keineswegs spiritueller Natur. Jedoch sollte man bedenken, dass im Fall einer rein neurophysiologischen Grundlage von NTE dann bei jedem ein solches Phänomen zu erwarten wäre, so wie beispielsweise auch die Symptome einer Hypoglykämie im Wesentlichen immer dieselben sind. Y1 - 2014 U6 - http://dx.doi.org/10.1055/s-0034-1387363 SN - 1439-4413 (E-Journal); 0012-0472 (Print); 1437-5982 (Print) VL - Jg. 139 IS - H. 51/52 SP - 2651 EP - 2654 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Murib, Mohammed Sharif A1 - Yeap, Weng-Siang A1 - Martens, Daan A1 - Bienstman, Peter A1 - Ceuninck, Ward de A1 - Grinsven, Bart van A1 - Schöning, Michael Josef A1 - Michiels, Luc A1 - Haenen, Ken A1 - Ameloot, Marcel A1 - Serpengüzel, Ali A1 - Wagner, Patrick T1 - Photonic detection and characterization of DNA using sapphire microspheres JF - Journal of biomedical optics N2 - A microcavity-based deoxyribonucleic acid (DNA) optical biosensor is demonstrated for the first time using synthetic sapphire for the optical cavity. Transmitted and elastic scattering intensity at 1510 nm are analyzed from a sapphire microsphere (radius 500  μm, refractive index 1.77) on an optical fiber half coupler. The 0.43 nm angular mode spacing of the resonances correlates well with the optical size of the sapphire sphere. Probe DNA consisting of a 36-mer fragment was covalently immobilized on a sapphire microsphere and hybridized with a 29-mer target DNA. Whispering gallery modes (WGMs) were monitored before the sapphire was functionalized with DNA and after it was functionalized with single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA). The shift in WGMs from the surface modification with DNA was measured and correlated well with the estimated thickness of the add-on DNA layer. It is shown that ssDNA is more uniformly oriented on the sapphire surface than dsDNA. In addition, it is shown that functionalization of the sapphire spherical surface with DNA does not affect the quality factor (Q≈104) of the sapphire microspheres. The use of sapphire is especially interesting because this material is chemically resilient, biocompatible, and widely used for medical implants. Y1 - 2014 U6 - http://dx.doi.org/10.1117/1.JBO.19.9.097006 SN - 1560-2281 (E-Journal); 1083-3668 (Print) VL - 19 IS - 9 SP - 097006 PB - SPIE CY - Bellingham ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Molinnus, Denise A1 - Beging, Stefan A1 - Schöning, Michael Josef T1 - Incorporating a hybrid urease-carbon nanotubes sensitive nanofilm on capacitive field-effect sensors for urea detection JF - Analytical chemistry N2 - The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor’s surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance–voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform. Y1 - 2014 U6 - http://dx.doi.org/10.1021/ac500458s SN - 1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print) VL - 86 IS - 11 SP - 5370 EP - 5375 PB - ACS Publications CY - Columbus ER - TY - JOUR A1 - Müller, Martin A1 - Hirschfeld, Julian A1 - Lambertz, Rita A1 - Schulze Lohoff, Andreas A1 - Lustfeld, Hans A1 - Pfeifer, Heinz A1 - Reißel, Martin T1 - Validation of a novel method for detecting and stabilizing malfunctioning areas in fuel cell stacks JF - Journal of power sources N2 - In this paper a setup for detecting malfunctioning areas of MEAs in fuel cell stacks is described. Malfunctioning areas generate electric cross currents inside bipolar plates. To exploit this we suggest bipolar plates consisting not of two but of three layers. The third one is a highly conducting layer and segmented such that the cross currents move along the segments to the surface of the stack where they can be measured by an inductive sensor. With this information a realistic model can be used to detect the malfunctioning area. Furthermore the third layer will prevent any current inhomogeneity of a malfunctioning cell to spread to neighbouring cells in the stack. In this work the results of measurements in a realistic cell setup will be compared with the results obtained in simulation studies with the same configuration. The basis for the comparison is the reliable characterisation of the electrical properties of the cell components and the implication of these results into the simulation model. The experimental studies will also show the limits in the maximum number of segments, which can be used for a reliable detection of cross currents. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.jpowsour.2014.08.045 SN - 1873-2755 (E-Journal); 0378-7753 (Print) VL - 272 SP - 225 EP - 232 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Guo, Yuanyuan A1 - Seki, Kosuke A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Device simulation of the light-addressable potentiometric sensor with a novel photoexcitation method for a higher spatial resolution JF - Procedia Engineering N2 - A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent. KW - Light-addressable Potentiometric Sensor KW - novel photoexcitation method KW - tilted constant illumination KW - spatial resolution Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.proeng.2014.11.369 SN - 1877-7058 N1 - EUROSENSORS 2014 ; European Conference on Solid-State Transducers <28, 2014> VL - 87 SP - 456 EP - 459 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, K. A1 - Seki, K. A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, T. T1 - Enhancement of the spatial resolution of the chemical imaging sensor by a hybrid fiber-optic illumination JF - Procedia Engineering N2 - The chemical imaging sensor, which is based on the principle of the light-addressable potentiometric sensor (LAPS), is a powerful tool to visualize the spatial distribution of chemical species on the sensor surface. The spatial resolution of this sensor depends on the diffusion of photocarriers excited by a modulated light. In this study, a novel hybrid fiber-optic illumination was developed to enhance the spatial resolution. It consists of a modulated light probe to generate a photocurrent signal and a ring of constant light, which suppresses the lateral diffusion of minority carriers excited by the modulated light. It is demonstrated that the spatial resolution was improved from 92 μm to 68 μm. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.proeng.2014.11.563 SN - 1877-7058 N1 - EUROSENSORS 2014 ; European Conference on Solid-State Transducers <28, 2014> VL - 87 SP - 612 EP - 615 PB - Elsevier CY - Amsterdam ER -