TY - CHAP A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - Biopolymer-degradation monitoring by chip-­based impedance spectroscopy technique T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 47 EP - 47 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Cherstvy, Andrey G. A1 - Pedraza, Angela M. A1 - Ingebrandt, Sven A1 - Schöning, Michael Josef T1 - Label-free electrical detection of DNA by means of field-effect nanoplate capacitors: Experiments and modeling JF - Physica Status Solidi (a) N2 - Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100710 SN - 1862-6319 VL - 209 SP - 925 EP - 934 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-Ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef ED - Yamaguchi, Takami T1 - Miniaturized and high-speed chemical imaging systems T2 - Nano-Biomedical Engineering 2012. Proceedings of the Tohoku University Global Centre of Excellence Programme, Sakura Hall, Tohoku University, Sendai Japan, 5 – 6 March 2012 Y1 - 2012 U6 - http://dx.doi.org/10.1142/9781848169067_0045 SP - 386 EP - 395 PB - World Scientific CY - Singapur ER - TY - JOUR A1 - Staat, Manfred A1 - Trenz, Eva A1 - Lohmann, Philipp A1 - Frotscher, Ralf A1 - Klinge, Uwe A1 - Tabaza, Ruth A1 - Kirschner-Hermanns, Ruth T1 - New measurements to compare soft tissue anchoring systems in pelvic floor surgery JF - Journal of Biomedical Materials Research Part B: Applied Biomaterials N2 - Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment Y1 - 2012 U6 - http://dx.doi.org/10.1002/jbm.b.32654 SN - 1552-4981 VL - 100B IS - 4 SP - 924 EP - 933 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Bergmann, Sandra A1 - Demuth, Bastian A1 - Sander, Volker T1 - A Web Framework for Workflow Submission and Monitoring via UNICORE 6 based on Distributable Scientific Workflow Templates JF - UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.) Y1 - 2011 SN - 9783893367504 N1 - UNICORE Summit ; (2011 ; 2011.07.07-08 ; Torun) ; Schriften des Forschungszentrums Jülich IAS Series 9 SP - 45 EP - 50 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Krott, Daniel A1 - Gerhards, Michael A1 - Skorupa, Sascha A1 - Sander, Volker T1 - NHiLA - Bridging the Gap Between .NET and UNICORE JF - UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.) Y1 - 2011 SN - 9783893367504 N1 - UNICORE Summit ; (2011 ; 2011.07.07-08 ; Torun) ; Schriften des Forschungszentrums Jülich IAS Series 9 SP - 77 EP - 86 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Gerhards, M. A1 - Skorupa, S. A1 - Sander, Volker A1 - Pfeiffer, P. A1 - Belloum, A. T1 - Towards a security framework for a WS-HumanTask processor JF - 7th International Conference on Network and Service Management (CNSM), 2011 Paris Y1 - 2011 SN - 978-3-901882-44-9 SP - 1 EP - 5 PB - IEEE CY - New York ER - TY - JOUR A1 - Bäcker, Matthias A1 - Raue, Markus A1 - Schusser, Sebastian A1 - Jeitner, C. A1 - Breuer, L. A1 - Wagner, P. A1 - Poghossian, Arshak A1 - Förster, Arnold A1 - Mang, Thomas A1 - Schöning, Michael Josef T1 - Microfluidic chip with integrated microvalves based on temperature- and pH-responsive hydrogel thin films JF - Physica Status Solidi (a) N2 - Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3–12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100763 SN - 1862-6319 VL - 209 IS - 5 SP - 839 EP - 845 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik JF - GIT : Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 SN - 0016-3538 VL - 56 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Gerhards, Michael A1 - Sander, Volker A1 - Belloum, Adam ED - Zimmermann, Wolf ED - Lee, Yong Woo ED - Demchenko, Yuri T1 - About the flexible Migration of Workflow Tasks to Clouds : Combining on- and off-premise Executions of Applications T2 - CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France N2 - An increasing number of applications target their executions on specific hardware like general purpose Graphics Processing Units. Some Cloud Computing providers offer this specific hardware so that organizations can rent such resources. However, outsourcing the whole application to the Cloud causes avoidable costs if only some parts of the application benefit from the specific expensive hardware. A partial execution of applications in the Cloud is a tradeoff between costs and efficiency. This paper addresses the demand for a consistent framework that allows for a mixture of on- and off-premise calculations by migrating only specific parts to a Cloud. It uses the concept of workflows to present how individual workflow tasks can be migrated to the Cloud whereas the remaining tasks are executed on-premise. KW - Workflow Orchestration KW - Workflow KW - Grid Computing KW - Cloud Service Broker KW - Cloud Computing Y1 - 2012 SN - 978-1-61208-216-5 SP - 82 EP - 87 PB - IARIA Journals ER -