TY - CHAP A1 - Streun, M. A1 - Al-Kaddoum, R. A1 - Parl, C. A1 - Pietrzyk, U. A1 - Ziemons, Karl A1 - Waasen, S. van T1 - Simulation studies of optical photons in monolithic block scintillators T2 - 2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio. Y1 - 2012 SN - 978-1-4673-0120-6 (electronic ISBN) SN - 978-1-4673-0118-3 (print ISBN) U6 - https://doi.org/10.1109/NSSMIC.2011.6154621 SP - 1380 EP - 1382 PB - IEEE CY - New York ER - TY - GEN A1 - Achten, Richard A1 - Bauer, Andreas A1 - Bertram, Walter A1 - Cremer, Markus A1 - Daemen, Jos A1 - Dehnhardt, Markus A1 - Fleischer, Manfred A1 - Kirchner, Peter A1 - Leyendecker, Marco A1 - Pietrzyk, Uwe A1 - Schmitz, Jakob A1 - Ziemons, Karl A1 - Zilles, Karl T1 - Vorrichtung zum Halten eines lebenden Objektes bei physiologischen Messungen N2 - Die vorliegende Erfindung betrifft eine Vorrichtung zum Halten eines lebenden Objektes bei physiologischen Messungen mit einem Basiselement und Mitteln zum Arretieren des lebenden Objektes, die atraumatische Ohrenhalter sowie ein Mundstück aufweisen, das mit einer Aussparung für die Zähne des Lebewesens versehen ist, mit einem Masseanteil von wenigstens 95% an glasfaserverstärktem Kunststoff. Y1 - 2005 N1 - Patent Anmelder : Forschungszentrum Jülich GmbH SP - 1 EP - 17 ER - TY - GEN A1 - Rongen, Heinz A1 - Ziemons, Karl A1 - Schiek, Michael A1 - Tass, Alexander T1 - Vorrichtung zur Messung biomedizinischer Daten eines Probanden und Verfahren zur Simulation des Probanden mit in Echtzeit verarbeiteten Daten T1 - Device for measuring biomedical data from a testee and method for stimulating the testee with data processed in real-time N2 - Die Erfindung betrifft eine Vorrichtung zur Messung biomedizinischer Daten eines Probanden, mit einem Messsystem zur Erhebung der Daten sowie einer ersten Hardware-Komponente zur Aufzeichnung der Daten. In einer Verbindungsleitung zur Übertragung der Daten vom Messsystem zur ersten Hardware-Komponente zur Aufzeichnung der Daten ist erfindungsgemäss ein Mittel zur galvanischen Auftrennung der Daten angeordnet. Auf diese Weise ist wenigstens die Duplizierung der Daten für Datenverarbeitungszwecke gewährleistet. Die auf diese Weise verarbeiteten Daten werden für ein Verfahren zur Echtzeit-Stimulation eines Probanden genutzt. Y1 - 2006 N1 - Auch veröffentlicht als EP2007276 ; US2009069662 ; US8301222 ; JP2009535071 ; WO2007118443 ; AT 533401 SP - 1 EP - 12 ER - TY - BOOK A1 - Simonis, Rainer T1 - Experimentelle Darstellung von Kr/Xe-Hydrat bei Drücken bis 160 bar KW - Krypton KW - Xenon KW - krypton xenon hydrate Y1 - 1985 N1 - Zugl.: Aachen, Techn. Hochsch., Diss. N1 - Berichte der Kernforschungsanlage Jülich ; 1995 PB - Zentralbibliothek d. Kernforschungsanlage CY - Jülich ER - TY - BOOK A1 - Simonis, Rainer A1 - Brücher, Heiner T1 - Verhalten von radioaktivem Krypton-85 in der Tiefsee : Abschlußbericht für d. Berichtszeitraum 1.10.1980 - 31.3.1983 KW - Krypton-85 Y1 - 1984 N1 - Spezielle Berichte der Kernforschungsanlage Jülich ; 267 PB - Zentralbibliothek d. Kernforschungsanlage CY - Jülich ER - TY - PAT A1 - Hofbauer, Peter A1 - Härtel, Günter A1 - Lösing, Karl-Heinrich A1 - Dorner, Robert A1 - Simonis, Rainer A1 - Schulte, Erasmus T1 - Brennstoffeinspritzsystem für Brennkraftmaschinen : Offenlegungsschrift DE 3833215 A1 ; Offenlegungstag: 28.12.89 N2 - Es wird ein Brennstoffeinspritzsystem für Brennkraftmaschinen vorgeschlagen, bei dem ein definiertes Teil eines fest vorgegebenen Brennstoffvolumens durch die Druckerhöhung innerhalb einer brennstoffeinschließenden Kammer eine definierte Brennstoffmenge über jeweils ein Rückschlagventil abgespritzt wird. Ein elektronisches Steuergerät berechnet die Dauer und/oder Intensität und gegebenenfalls die Impulsfolge eines zum Beispiel zur Verdampfung einer bestimmten Brennstoffmenge erforderlichen Laserimpulses. Das System kann für Ein- oder Mehrstelleinspritzung Verwendung finden. KW - Brennkraftmaschine KW - Brennstoffeinspritzsystem Y1 - 1989 PB - Deutsches Patent- und Markenamt CY - München ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER -