TY - CHAP A1 - Sauerborn, Markus A1 - Hoffschmidt, Bernhard A1 - Göttsche, Joachim A1 - Schmitz, S. A1 - Rebholz, C. A1 - Ansorge, F. A1 - Ifland, D. T1 - Mini-Spiegel-Array für solarthermische Kraftwerke : [Vortragsfolien] T2 - DPG-Frühjahrstagung, Arbeitskreis Energie, Hamburg 03.03.2009 Y1 - 2009 SP - 1 EP - 10 ER - TY - CHAP A1 - May, Martin A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - Latzke, Markus A1 - Bäumer, Klaus A1 - Uhlig, Ralf A1 - Söhn, Matthias A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Experimental facility for investigations of wire mesh absorbers for pressurized gases T2 - AIP Conference Proceedings Y1 - 2019 U6 - https://doi.org/10.1063/1.5117547 SN - 0094243X VL - 2126 SP - 030035-1 EP - 030035-9 ER - TY - CHAP A1 - Göttsche, Joachim T1 - Einsatz nichtinvasiver Messtechnik zur Betriebsanalyse T2 - Energieeffizienz + Bestand : energetische Sanierung von Gebäuden ; internationales Anwenderforum ; 14./15. Februar 2008, Kloster Banz, Bad Staffelstein Y1 - 2008 SN - 978-3-934681-68-2 SP - 44 EP - 51 PB - OTTI CY - Regensburg ER - TY - CHAP A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Flesch, Robert A1 - Alexopoulos, Spiros A1 - Herrmann, Ulf T1 - Improved efficiency prediction of a molten salt receiver based on dynamic cloud passage simulation T2 - AIP Conference Proceedings Y1 - 2019 SN - 978-0-7354-1866-0 U6 - https://doi.org/10.1063/1.5117566 VL - 2126 IS - 1 SP - 030054-1 EP - 030054-8 ER - TY - CHAP A1 - Teixeira Boura, Cristiano José A1 - Niederwestberg, Stefan A1 - McLeod, Jacqueline A1 - Herrmann, Ulf A1 - Hoffschmidt, Bernhard T1 - Development of heat exchanger for high temperature energy storage with bulk materials T2 - AIP Conference Proceedings Y1 - 2016 U6 - https://doi.org/10.1063/1.4949106 VL - 1734 IS - 1 SP - 050008-1 EP - 050008-7 ER - TY - CHAP A1 - Blanke, Tobias A1 - Dring, Bernd A1 - Vontein, Marius A1 - Kuhnhenne, Markus T1 - Climate Change Mitigation Potentials of Vertical Building Integrated Photovoltaic T2 - 8th International Workshop on Integration of Solar Power into Power Systems : 16-17 October 2018, Stockholm, Sweden Y1 - 2018 SP - 1 EP - 7 ER - TY - CHAP A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard A1 - Rau, Christoph A1 - Schwarzbözl, Peter T1 - Simulation results for a hybridization concept of a small solar tower power plant T2 - SolarPACES 2009 : electricity, fuels and clean water powered by the sun ; 15 - 18 September 2009, Berlin, Germany ; the 15th SolarPACES conference ; proceedings Y1 - 2009 SN - 9783000287558 PB - Deutsches Zentrum f. Luft- u. Raumfahrt CY - Stuttgart ER - TY - CHAP A1 - Schulte, Jonas A1 - Schwager, Christian A1 - Noureldin, Kareem A1 - May, Martin A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Gradient controlled startup procedure of a molten-salt power-to-heat energy storage plant based on dynamic process simulation T2 - SolarPACES: Solar Power & Chemical Energy Systems N2 - The integration of high temperature thermal energy storages into existing conventional power plants can help to reduce the CO2 emissions of those plants and lead to lower capital expenditures for building energy storage systems, due to the use of synergy effects [1]. One possibility to implement that, is a molten salt storage system with a powerful power-to-heat unit. This paper presents two possible control concepts for the startup of the charging system of such a facility. The procedures are implemented in a detailed dynamic process model. The performance and safety regarding the film temperatures at heat transmitting surfaces are investigated in the process simulations. To improve the accuracy in predicting the film temperatures, CFD simulations of the electrical heater are carried out and the results are merged with the dynamic model. The results show that both investigated control concepts are safe regarding the temperature limits. The gradient controlled startup performed better than the temperature-controlled startup. Nevertheless, there are several uncertainties that need to be investigated further. KW - Power plants KW - Energy storage KW - Associated liquids Y1 - 2023 SN - 978-0-7354-4623-6 U6 - https://doi.org/10.1063/5.0148741 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - SolarPACES: SOLAR POWER & CHEMICAL ENERGY SYSTEMS: 27th International Conference on Concentrating Solar Power and Chemical Energy Systems, 27 September–1 October 2021, Online IS - 2815 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Oetringer, Kerstin A1 - Dümmler, Andreas A1 - Göttsche, Joachim T1 - Neues Modell zur 1D-Simulation der indirekten Verdunstungskühlung T2 - DKV‐Tagung 2020, AA II.1 N2 - Im Projekt Coolplan‐ AIR geht es um die Fortentwicklung und Feld‐ Validierung eines Berechnungs‐ und Auslegungstools zur energieeffizienten Kühlung von Gebäuden mit luftgestützten Systemen. Neben dem Aufbau und der Weiterentwicklung von Simulationsmodellen erfolgen Vermessungen der Gesamtsysteme anhand von Praxisanlagen im Feld. Eine der betrachteten Anlagen arbeitet mit indirekter Verdunstung. Diese Veröffentlichung zeigt den Entwicklungsprozess und den Aufbau des Simulationsmodells zur Verdunstungskühlung in der Simulationsumgebung Matlab‐ Simulink mit der CARNOT‐ Toolbox. Das besondere Augenmerk liegt dabei auf dem physikalischen Modell des Wärmeübertragers, in dem die Verdunstung implementiert ist. Dem neuen Modellansatz liegt die Annahme einer aus der Enthalpie‐ Betrachtung hergeleiteten effektiven Wärmekapazität zugrunde. Des Weiteren wird der Befeuchtungsgrad als konstant angesehen und eine standardisierte Zunahme der Wärmeübertragung des feuchten gegenüber dem trockenen Wärmeübertrager angenommen. Die Validierung des Modells erfolgte anhand von Literaturdaten. Für den trockenen Wärmetauscher ist der maximale absolute Fehler der berechneten Austrittstemperatur (Zuluft) kleiner als ±0.1 K und für den nassen Wärmetauscher (Kühlfall) unter der Annahme eines konstanten Verdunstungsgrades kleiner als ±0.4 K. Y1 - 2020 N1 - Deutsche Kälte- und Klimatagung, 19-20 November 2020, online SP - 250 EP - 262 ER - TY - CHAP A1 - Rendon, Carlos A1 - Dieckmann, Simon A1 - Weidle, Mathias A1 - Dersch, Jürgen A1 - Teixeira Boura, Cristiano José A1 - Polklas, Thomas A1 - Kuschel, Marcus A1 - Herrmann, Ulf T1 - Retrofitting of existing parabolic trough collector power plants with molten salt tower systems T2 - AIP Conference Proceedings Y1 - 2018 U6 - https://doi.org/10.1063/1.5067030 VL - 2033 IS - 1 SP - 030014-1 EP - 030014-8 ER -