TY - JOUR A1 - Otten, Dennis A1 - Weber, Tobias A1 - Arent, Jan-Christoph T1 - Manufacturing Process Simulation – On Its Way to Industrial Application JF - International Journal of Aviation, Aeronautics, and Aerospace N2 - Manufacturing process simulation (MPS) has become more and more important for aviation and the automobile industry. A highly competitive market requires the use of high performance metals and composite materials in combination with reduced manufacturing cost and time as well as a minimization of the time to market for a new product. However, the use of such materials is expensive and requires sophisticated manufacturing processes. An experience based process and tooling design followed by a lengthy trial-and-error optimization is just not contemporary anymore. Instead, a tooling design process aided by simulation is used more often. This paper provides an overview of the capabilities of MPS in the fields of sheet metal forming and prepreg autoclave manufacturing of composite parts summarizing the resulting benefits for tooling design and manufacturing engineering. The simulation technology is explained briefly in order to show several simplification and optimization techniques for developing industrialized simulation approaches. Small case studies provide examples of an efficient application on an industrial scale. Y1 - 2018 U6 - https://doi.org/10.15394/ijaaa.2018.1217 SN - 2374-6793 VL - 5 IS - 2 PB - Embry-Riddle Aeronautical University CY - Daytona Beach, Fla. ER - TY - CHAP A1 - Jockwer, R. A1 - Kleiber, M. A1 - Uibel, Thomas ED - Görlacher, Rainer T1 - Criteria for Evaluating the Simplification of Design Rules for Dowel-type Fasteners T2 - International Network on Timber Engineering Research, INTER : proceedings, meeting 51, 10 - 13 August 2016, Tallinn, Estonia Y1 - 2018 SP - 461 EP - 466 PB - Timber Scientific Publishing, KIT Holzbau und Baukonstruktionen CY - Karlsruhe ER - TY - JOUR A1 - Svaneborg, Carsten A1 - Karimi-Varzaneh, Hossein Ali A1 - Hojdis, Nils A1 - Fleck, Franz A1 - Everaers, Ralf T1 - Kremer-Grest Models for Universal Properties of Specific Common Polymer Species JF - Soft Condensed Matter N2 - The Kremer-Grest (KG) bead-spring model is a near standard in Molecular Dynamic simulations of generic polymer properties. It owes its popularity to its computational efficiency, rather than its ability to represent specific polymer species and conditions. Here we investigate how to adapt the model to match the universal properties of a wide range of chemical polymers species. For this purpose we vary a single parameter originally introduced by Faller and Müller-Plathe, the chain stiffness. Examples include polystyrene, polyethylene, polypropylene, cis-polyisoprene, polydimethylsiloxane, polyethyleneoxide and styrene-butadiene rubber. We do this by matching the number of Kuhn segments per chain and the number of Kuhn segments per cubic Kuhn volume for the polymer species and for the Kremer-Grest model. We also derive mapping relations for converting KG model units back to physical units, in particular we obtain the entanglement time for the KG model as function of stiffness allowing for a time mapping. To test these relations, we generate large equilibrated well entangled polymer melts, and measure the entanglement moduli using a static primitive-path analysis of the entangled melt structure as well as by simulations of step-strain deformation of the model melts. The obtained moduli for our model polymer melts are in good agreement with the experimentally expected moduli. Y1 - 2018 IS - 1606.05008 ER - TY - JOUR A1 - Altherr, Lena A1 - Leise, Philipp A1 - Pfetsch, Marc E. A1 - Schmitt, Andreas T1 - Algorithmic design and resilience assessment of energy efficient high-rise water supply systems JF - Applied Mechanics and Materials N2 - High-rise water supply systems provide water flow and suitable pressure in all levels of tall buildings. To design such state-of-the-art systems, the consideration of energy efficiency and the anticipation of component failures are mandatory. In this paper, we use Mixed-Integer Nonlinear Programming to compute an optimal placement of pipes and pumps, as well as an optimal control strategy.Moreover, we consider the resilience of the system to pump failures. A resilient system is able to fulfill a predefined minimum functionality even though components fail or are restricted in their normal usage. We present models to measure and optimize the resilience. To demonstrate our approach, we design and analyze an optimal resilient decentralized water supply system inspired by a real-life hotel building. KW - MINLP KW - Buffering Capacity KW - Uncertainty KW - Water Supply Networks KW - Booster Stations Y1 - 2018 U6 - https://doi.org/10.4028/www.scientific.net/AMM.885.211 SN - 1662-7482 VL - 885 SP - 211 EP - 223 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - https://doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - JOUR A1 - de Blois, Eric A1 - de Zanger, Rory M. S. A1 - Paulßen, Elisabeth A1 - Sze Chan, Ho A1 - Breeman, Wouter A. P. T1 - Semi-automated system for concentrating 68Ga-eluate to obtain high molar and volume concentration of 68Ga-Radiopharmaca for preclinical applications JF - Nuclear Medicine and Biology N2 - 68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity. Y1 - 2018 U6 - https://doi.org/10.1016/j.nucmedbio.2018.06.006 VL - 64-65 SP - 16 EP - 21 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Schmidts, Oliver A1 - Kraft, Bodo A1 - Schreiber, Marc A1 - Zündorf, Albert T1 - Continuously evaluated research projects in collaborative decoupled environments T2 - 2018 ACM/IEEE 5th International Workshop on Software Engineering Research and Industrial PracticePractice, May 29, 2018, Gothenburg, Sweden : SER&IP' 18 N2 - Often, research results from collaboration projects are not transferred into productive environments even though approaches are proven to work in demonstration prototypes. These demonstration prototypes are usually too fragile and error-prone to be transferred easily into productive environments. A lot of additional work is required. Inspired by the idea of an incremental delivery process, we introduce an architecture pattern, which combines the approach of Metrics Driven Research Collaboration with microservices for the ease of integration. It enables keeping track of project goals over the course of the collaboration while every party may focus on their expert skills: researchers may focus on complex algorithms, practitioners may focus on their business goals. Through the simplified integration (intermediate) research results can be introduced into a productive environment which enables getting an early user feedback and allows for the early evaluation of different approaches. The practitioners’ business model benefits throughout the full project duration. Y1 - 2018 SP - 1 EP - 9 PB - ACM CY - New York, NY ER - TY - JOUR A1 - Rupp, Matthias A1 - Schulze, Sven A1 - Kuperjans, Isabel T1 - Comparative life cycle analysis of conventional and hybrid heavy-duty trucks JF - World electric vehicle journal N2 - Heavy-duty trucks are one of the main contributors to greenhouse gas emissions in German traffic. Drivetrain electrification is an option to reduce tailpipe emissions by increasing energy conversion efficiency. To evaluate the vehicle’s environmental impacts, it is necessary to consider the entire life cycle. In addition to the daily use, it is also necessary to include the impact of production and disposal. This study presents the comparative life cycle analysis of a parallel hybrid and a conventional heavy-duty truck in long-haul operation. Assuming a uniform vehicle glider, only the differing parts of both drivetrains are taken into account to calculate the environmental burdens of the production. The use phase is modeled by a backward simulation in MATLAB/Simulink considering a characteristic driving cycle. A break-even analysis is conducted to show at what mileage the larger CO2eq emissions due to the production of the electric drivetrain are compensated. The effect of parameter variation on the break-even mileage is investigated by a sensitivity analysis. The results of this analysis show the difference in CO2eq/t km is negative, indicating that the hybrid vehicle releases 4.34 g CO2eq/t km over a lifetime fewer emissions compared to the diesel truck. The break-even analysis also emphasizes the advantages of the electrified drivetrain, compensating the larger emissions generated during production after already a distance of 15,800 km (approx. 1.5 months of operation time). The intersection coordinates, distance, and CO2eq, strongly depend on fuel, emissions for battery production and the driving profile, which lead to nearly all parameter variations showing an increase in break-even distance. Y1 - 2018 U6 - https://doi.org/10.3390/wevj9020033 SN - 2032-6653 VL - 9 IS - 2 SP - Article No. 33 PB - MDPI CY - Basel ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred T1 - Optical strain measurement for the modeling of surgical meshes and their porosity JF - Current Directions in Biomedical Engineering N2 - The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes. Y1 - 2018 U6 - https://doi.org/10.1515/cdbme-2018-0045 SN - 2364-5504 VL - Band 4 IS - 1 SP - 181 EP - 184 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - Computational comparison of different textile implants to correct apical prolapse in females JF - Current Directions in Biomedical Engineering N2 - Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared. Y1 - 2018 U6 - https://doi.org/10.1515/cdbme-2018-0159 VL - 4 IS - 1 SP - 661 EP - 664 PB - De Gruyter CY - Berlin ER -