TY - JOUR A1 - Gazda, Quentin A1 - Maurischat, Andreas T1 - Special functions and Gauss-Thakur sums in higher rank and dimension Y1 - 2020 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Gebhardt, Andreas A1 - Hoetter, Jan-Steffen T1 - Rapid Tooling T2 - CIRP Encyclopedia of Production Engineering Y1 - 2019 SN - 978-3-662-53120-4 U6 - https://doi.org/10.1007/978-3-662-53120-4 SP - 39 EP - 52 PB - Springer CY - Berlin, Heidelberg ER - TY - CHAP A1 - Chavez Bermudez, Victor Francisco A1 - Wollert, Jörg T1 - Arduino based Framework for Rapid Application Development of a Generic IO-Link interface T2 - Kommunikation und Bildverarbeitung in der Automation. Ausgewählte Beiträge der Jahreskolloquien KommA und BVAu 2018 N2 - The implementation of IO-Link in the automation industry has increased over the years. Its main advantage is it offers a digital point-to-point plugand-play interface for any type of device or application. This simplifies the communication between devices and increases productivity with its different features like self-parametrization and maintenance. However, its complete potential is not always used. The aim of this paper is to create an Arduino based framework for the development of generic IO-Link devices and increase its implementation for rapid prototyping. By generating the IO device description file (IODD) from a graphical user interface, and further customizable options for the device application, the end-user can intuitively develop generic IO-Link devices. The peculiarity of this framework relies on its simplicity and abstraction which allows to implement any sensor functionality and virtually connect any type of device to an IO-Link master. This work consists of the general overview of the framework, the technical background of its development and a proof of concept which demonstrates the workflow for its implementation. Y1 - 2020 SN - 978-3-662-59895-5 SN - 978-3-662-59894-8 U6 - https://doi.org/10.1007/978-3-662-59895-5_2 N1 - Beiträge der Jahreskolloquien KommA und BVAu 2018; Teil der Buchserie "Technologien für die intelligente Automation" (TIA,volume 12) SP - 21 EP - 33 PB - Springer Vieweg CY - Berlin ER - TY - JOUR A1 - Conzen, Catharina A1 - Albanna, Walid A1 - Weiss, Miriam A1 - Kürten, David A1 - Vilser, Walthard A1 - Kotliar, Konstantin A1 - Zäske, Charlotte A1 - Clusmann, Hans A1 - Schubert, Gerrit Alexander T1 - Vasoconstriction and Impairment of Neurovascular Coupling after Subarachnoid Hemorrhage: a Descriptive Analysis of Retinal Changes JF - Translational Stroke Research N2 - Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5–14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome. Y1 - 2018 U6 - https://doi.org/10.1007/s12975-017-0585-8 SN - 1868-601X IS - 9 SP - 284 EP - 293 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Bernecker, Andreas A1 - Boyer, Pierre C. A1 - Gathmann, Christina T1 - The Role of Electoral Incentives for Policy Innovation: Evidence from the US Welfare Reform JF - American Economic Journal: Economic Policy Y1 - 2021 U6 - https://doi.org/10.1257/pol.20190690 SN - 1945-774X VL - 13 IS - 2 SP - 26 EP - 57 PB - American Economic Association CY - Nashville, Tenn. ER - TY - CHAP A1 - Hoegen, Anne von A1 - Doncker, Rik W. De A1 - Bragard, Michael A1 - Hoegen, Svenja von T1 - Problem-based learning in automation engineering: performing a remote laboratory aession aerving various educational attainments T2 - 2021 IEEE Global Engineering Education Conference (EDUCON) N2 - During the Covid-19 pandemic, vocational colleges, universities of applied science and technical universities often had to cancel laboratory sessions requiring students’ attendance. These above of all are of decisive importance in order to give learners an understanding of theory through practical work.This paper is a contribution to the implementation of distance learning for laboratory work applicable for several upper secondary educational facilities. Its aim is to provide a paradigm for hybrid teaching to analyze and control a non-linear system depicted by a tank model. For this reason, we redesign a full series of laboratory sessions on the basis of various challenges. Thus, it is suitable to serve different reference levels of the European Qualifications Framework (EQF).We present problem-based learning through online platforms to compensate the lack of a laboratory learning environment. With a task deduced from their future profession, we give students the opportunity to develop own solutions in self-defined time intervals. A requirements specification provides the framework conditions in terms of time and content for students having to deal with the challenges of the project in a self-organized manner with regard to inhomogeneous previous knowledge. If the concept of Complete Action is introduced in classes before, they will automatically apply it while executing the project.The goal is to combine students’ scientific understanding with a procedural knowledge. We suggest a series of remote laboratory sessions that combine a problem formulation from the subject area of Measurement, Control and Automation Technology with a project assignment that is common in industry by providing extracts from a requirements specification. Y1 - 2021 U6 - https://doi.org/10.1109/EDUCON46332.2021.9453925 N1 - 2021 IEEE Global Engineering Education Conference (EDUCON), 21-23 April 2021, Vienna, Austria SP - 1605 EP - 1614 PB - IEEE CY - New York, NY ER - TY - CHAP A1 - Hüning, Felix A1 - Stüttgen, Marcel T1 - Work in Progress: Interdisciplinary projects in times of COVID-19 crisis – challenges, risks and chances T2 - 2021 IEEE Global Engineering Education Conference (EDUCON) N2 - Project work and inter disciplinarity are integral parts of today's engineering work. It is therefore important to incorporate these aspects into the curriculum of academic studies of engineering. At the faculty of Electrical Engineering and Information Technology an interdisciplinary project is part of the bachelor program to address these topics. Since the summer term 2020 most courses changed to online mode during the Covid-19 crisis including the interdisciplinary projects. This online mode introduces additional challenges to the execution of the projects, both for the students as well as for the lecture. The challenges, but also the risks and chances of this kind of project courses are subject of this paper, based on five different interdisciplinary projects Y1 - 2021 U6 - https://doi.org/10.1109/EDUCON46332.2021.9454006 N1 - 2021 IEEE Global Engineering Education Conference (EDUCON), 21-23 April 2021, Vienna, Austria SP - 1175 EP - 1179 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Hugenroth, Kristin A1 - Borchardt, Ralf A1 - Ritter, Philine A1 - Groß‑Hardt, Sascha A1 - Meyns, Bart A1 - Verbelen, Tom A1 - Steinseifer, Ulrich A1 - Kaufmann, Tim A. S. A1 - Engelmann, Ulrich M. T1 - Optimizing cerebral perfusion and hemodynamics during cardiopulmonary bypass through cannula design combining in silico, in vitro and in vivo input JF - Scientific Reports N2 - Cardiopulmonary bypass (CPB) is a standard technique for cardiac surgery, but comes with the risk of severe neurological complications (e.g. stroke) caused by embolisms and/or reduced cerebral perfusion. We report on an aortic cannula prototype design (optiCAN) with helical outflow and jet-splitting dispersion tip that could reduce the risk of embolic events and restores cerebral perfusion to 97.5% of physiological flow during CPB in vivo, whereas a commercial curved-tip cannula yields 74.6%. In further in vitro comparison, pressure loss and hemolysis parameters of optiCAN remain unaffected. Results are reproducibly confirmed in silico for an exemplary human aortic anatomy via computational fluid dynamics (CFD) simulations. Based on CFD simulations, we firstly show that optiCAN design improves aortic root washout, which reduces the risk of thromboembolism. Secondly, we identify regions of the aortic intima with increased risk of plaque release by correlating areas of enhanced plaque growth and high wall shear stresses (WSS). From this we propose another easy-to-manufacture cannula design (opti2CAN) that decreases areas burdened by high WSS, while preserving physiological cerebral flow and favorable hemodynamics. With this novel cannula design, we propose a cannulation option to reduce neurological complications and the prevalence of stroke in high-risk patients after CPB. Y1 - 2021 U6 - https://doi.org/10.1038/s41598-021-96397-2 SN - 2045-2322 VL - 11 IS - Art. No. 16800 SP - 1 EP - 12 PB - Springer CY - Berlin ER - TY - CHAP A1 - Merkens, Torsten A1 - Hebel, Christoph T1 - Sharing mobility concepts – flexible, sustainable, smart T2 - Proceedings of the 1st UNITED – Southeast Asia Automotive Interest Group (SAIG) International Conference KW - Sharing mobility KW - electro mobility KW - business models KW - mobility behaviour Y1 - 2021 SN - 978-3-902103-94-9 N1 - 1st UNITED-SAIG International Conference, 21-22 APR 2021, Chulalongkorn University, Thailand SP - 43 EP - 44 ER - TY - JOUR A1 - Brockhaus, Moritz K. A1 - Behbahani, Mehdi A1 - Muris, Farina A1 - Jansen, Sebastian V. A1 - Schmitz- Rode, Thomas A1 - Steinseifer, Ulrich A1 - Clauser, Johanna C. T1 - In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept JF - Artificial Organs N2 - Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential. Y1 - 2021 U6 - https://doi.org/10.1111/aor.14046 SN - 1525-1594 VL - 45 IS - 12 SP - 1513 EP - 1521 PB - Wiley CY - Weinheim ER -