TY - RPRT A1 - Feldmann, M. A1 - Kuhnhenne, M. A1 - Döring, Bernd A1 - Pyschny, D. A1 - Lawson, R.M. A1 - Chuter, R.D. A1 - Boudjabeur, S. A1 - Lecomte-Labory, F. A1 - Airaksinen, M. A1 - Heikkinen, J. A1 - Laamanen, J. A1 - Albart, P. A1 - D'Haeyer, R. A1 - Chica, J.A. A1 - Maseda, J.M. A1 - Amundarain, A. A1 - Rips, M.O. A1 - Nuñez, J.A. A1 - Macías, O. A1 - Beguin, P. A1 - Ben Larbi, A. T1 - Energy and thermal improvements for construction in steel (ETHICS) - EUR 26010 N2 - ETHICS is concerned with evaluating, measuring and making improvements in the thermal and energy performance of steel-clad and steel-framed buildings. It addresses basic building physics performance at a laboratory and full-scale level, and the preparation of design guidance for commercial, industrial and residential buildings. It includes the development of design tools to assist users in assessing whole-building performance, and calibrates these tools against whole-building measurements, which will be obtained from this research. Opportunities for renewable energy and other energy-saving features will be assessed. This project focuses on objectives that are of particular interest for the design of new steel constructions regarding energy efficiency. ETHICS investigates the as-built performance by on-site tests regarding air tightness and heat transfer properties of the building envelope and by monitoring the energy consumption and thermal comfort of selected up-to-date steel buildings. As energy efficiency is a key requirement for design and construction of buildings in the future, this project provides well-founded scientific data, which prove the high energy performance of current steel constructions and work out details for further improvements to maintain and extend the position of steel products in the construction sector. KW - steel KW - metal structure KW - building technique KW - energy efficiency KW - thermal insulation KW - industrial research KW - research report Y1 - 2013 SN - 978-92-79-30789-8 U6 - https://doi.org/10.2777/17106 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - RPRT A1 - Kesti, Jyrki A1 - Mononen, Tarmo A1 - Lautso, Petteri A1 - Döring, Bernd A1 - Reger, Vitali A1 - Holopainen, R. A1 - Jung, N. A1 - Shemeikka, J. A1 - Nieminen, J. A1 - Reda, F. A1 - Lawson, Mark A1 - Botti, Andrea A1 - Hall, R. A1 - Zold, A. A1 - Buday, T. T1 - Zero energy solutions for multifunctional steel intensive commercial buildings (ZEMUSIC) - EUR 27627 N2 - The broad commercial objective of this project was the sustainable value creation in steel building technology by addressing the ways in which significant energy reductions can be made in the operation phase of multi-storey commercial buildings. A review on energy efficient commercial buildings in Europe has been carried out consisting of several case studies from different countries. The project included development of zero-energy concepts for reducing energy demand as well as concepts for heating, cooling and ventilation systems by utilising renewable energy sources in three different climates. Also alternative structural frame solutions were developed and analyzed in respect of structural and MEP (mechanical, electrical and plumbing solutions) features. An innovative long span floor system with integrated MEP routings promises a cost effective alternative for sophisticated ventilation distribution and radiant heating and cooling systems, allowing for high energy efficiency and high quality interior climate. The report includes also review of best architectural practices for integrated renewable energy solutions including different design strategies for building facades of zero energy buildings. Interesting results and design basis are also presented for steel energy pile concept, where structural foundation piles are utilized for ground energy harvesting. Life cycle cost calculations for near zero energy office building based on developed technologies show that a near zero energy construction is also profitable. The results and work methods of the project have been summarized in the form of design guidance that offers designers the knowledge gained in a form that can be easily understood. KW - steel KW - iron and steel industry KW - resistance of materials KW - materials technology KW - metal structure KW - research project KW - building industry KW - building materials KW - renewable energy KW - designs and models KW - research report KW - guide Y1 - 2015 SN - 978-92-79-54071-4 U6 - https://doi.org/10.2777/111520 SN - 1831-9424 N1 - Enthalten: Appendix Design Guide: Deliverable Report WP6.4 Design Guide for steel intensive nearly zero office buildings (83 Seiten) PB - Publications Office of the European Union CY - Luxembourg ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - SAR Simulations & Safety JF - NeuroImage Y1 - 2017 U6 - https://doi.org/10.1016/j.neuroimage.2017.03.035 SN - 1053-8119 IS - Epub ahead of print PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Noureddine, Yacine A1 - Kraff, Oliver A1 - Ladd, Mark E. A1 - Wrede, Karsten H. A1 - Chen, Bixia A1 - Quick, Harald H. A1 - Schaefers, Gregor A1 - Bitz, Andreas T1 - In vitro and in silico assessment of RF-induced heating around intracranial aneurysm clips at 7 Tesla JF - Magnetic Resonance in Medicine Y1 - 2017 U6 - https://doi.org/10.1002/mrm.26650 SN - 1522-2594 IS - Early view PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits JF - Medical Physics Y1 - 2017 U6 - https://doi.org/10.1002/mp.12034 N1 - This article is corrected by: Errata: Erratum: “RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits” [Med. Phys. 44(1), 143–157 (2017)] Volume 44, Issue 2, 772 VL - 44 IS - 1 SP - 143 EP - 157 ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Vos, Eline K. A1 - Maas, Marnix C. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Uden, Mark J. van A1 - Kobus, Thiele A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer JF - Investigative Radiology N2 - Objectives The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T. Materials and Methods In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Results Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Conclusions Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels. Y1 - 2014 U6 - https://doi.org/10.1097/RLI.0000000000000012 SN - 1536-0210 VL - 49 IS - 5 SP - 363 EP - 372 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. ER - TY - CHAP A1 - Feldmann, M. A1 - Döring, Bernd A1 - Pyschny, D. T1 - Floor systems; Sustainabilty analyses and assessments of steel bridges T2 - Sustainable steel buildings : a practical guide for structures and envelopes Y1 - 2016 SN - 978-1-118-74079-8 (PDF) SN - 978-1-118-74111-5 SP - 198 EP - 223 PB - Wiley Blackwell CY - Chichester, West Sussex ER - TY - JOUR A1 - Maas, Marnix C. A1 - Vos, Eline K. A1 - Lagemaat, Miriam W. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Kobus, Thiele A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Scheenen, Tom W. J. T1 - Feasibility of T₂-weighted turbo spin echo imaging of the human prostate at 7 tesla JF - Magnetic Resonance in Medicine N2 - Purpose To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only. Methods Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000–3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate. Results High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction. Conclusion High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array. Y1 - 2014 U6 - https://doi.org/10.1002/mrm.24818 SN - 1522-2594 VL - 71 IS - 5 SP - 1711 EP - 1719 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Umutlu, Lale A1 - Kraff, Oliver A1 - Fischer, Anja A1 - Kinner, Sonja A1 - Maderwald, Stefan A1 - Nassenstein, Kai A1 - Nensa, Felix A1 - Grüneisen, Johannes A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Forsting, Michael A1 - Ladd, Mark E. A1 - Lauenstein, Thomas C. T1 - Seven-Tesla MRI of the female pelvis JF - European Radiology Y1 - 2013 U6 - https://doi.org/10.1007/s00330-013-2868-0 SN - 1432-1084 VL - 23 IS - 9 SP - 2364 EP - 2373 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bitz, Andreas A1 - Felder, Jorg A1 - Wittig, Tilmann T1 - Designing MRI Coils with Aid of Simulation JF - Microwaves & RF Y1 - 2013 SN - 0745-2993 VL - 52 IS - 7 SP - 56 PB - Penton CY - Cleveland, Ohio ER -