TY - CHAP A1 - Blake, D. A1 - Moens, L. A1 - Hale, M.-J. A1 - Price, Henry A1 - Keaney, David W. A1 - Herrmann, Ulf ED - Steinfeld, Aldo T1 - New heat transfer and storage fluids for parabolic trough solar thermal electric plants T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 63 EP - 66 PB - Paul Scherrer Inst. CY - Villingen ER - TY - JOUR A1 - Feichtinger, Linda M. A1 - Eilmann, Britta A1 - Buchmann, Nina A1 - Rigling, Andreas T1 - Trait-specific responses of Scots pine to irrigation on a short vs long time scale JF - Tree Physiology Y1 - 2015 U6 - https://doi.org/10.1093/treephys/tpu114 SN - 1758-4469 (Online) SN - 0829-318X (Print) N1 - Ab 12 Monaten nach Veröffentlichung kostenfrei zugänglich. VL - 35 IS - 00 SP - 1 EP - 12 PB - Heron CY - Victoria, BC ER - TY - CHAP A1 - Kelly, Bruce A1 - Herrmann, Ulf A1 - Hale, M.-J. T1 - Optimization Studies for Integrated Solar Combined Cycle Systems T2 - Solar engineering 2001 : proceedings of the International Solar Energy Conference ; presented at the 2001 International Solar Energy Conference, a part of Forum 2001 - Solar energy: the power to choose, April 21 - 25, 2001, Washington, D.C. Y1 - 2001 SN - 0-7918-1670-2 N1 - International Solar Energy Conference SP - 393 EP - 398 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard A1 - Crookston, B.M. T1 - Energy dissipation of a Type III basin under design and adverse conditions for stepped and smooth spillways JF - Journal of Hydraulic Engineering N2 - New information regarding the influence of a stepped chute on the hydraulic performance of the United States Bureau of Reclamation (Reclamation) Type III hydraulic jump stilling basin is presented for design (steady) and adverse (decreasing tailwater) conditions. Using published experimental data and computational fluid dynamics (CFD) models, this paper presents a detailed comparison between smooth-chute and stepped-chute configurations for chute slopes of 0.8H:1V and 4H:1V and Froude numbers (F) ranging from 3.1 to 9.5 for a Type III basin designed for F = 8. For both stepped and smooth chutes, the relative role of each basin element was quantified, up to the most hydraulic extreme case of jump sweep-out. It was found that, relative to a smooth chute, the turbulence generated by a stepped chute causes a higher maximum velocity decay within the stilling basin, which represents an enhancement of the Type III basin’s performance but also a change in the relative role of the basin elements. Results provide insight into the ability of the CFD models [unsteady Reynolds-averaged Navier-Stokes (RANS) equations with renormalization group (RNG) k-ϵ turbulence model and volume-of-fluid (VOF) for free surface tracking] to predict the transient basin flow structure and velocity profiles. Type III basins can perform adequately with a stepped chute despite the effects steps have on the relative role of each basin element. It is concluded that the classic Type III basin design, based upon methodology by reclamation specific to smooth chutes, can be hydraulically improved for the case of stepped chutes for design and adverse flow conditions using the information presented herein. Y1 - 2018 U6 - https://doi.org/10.1061/(ASCE)HY.1943-7900.0001482 SN - 0733-9429 N1 - Article number 04018036 VL - 144 IS - 7 PB - ASCE CY - Reston, Va. ER - TY - JOUR A1 - Teumer, T. A1 - Capitain, C. A1 - Ross-Jones, J. A1 - Tippkötter, Nils A1 - Rädle, M. A1 - Methner, F.-J. T1 - In-line Haze Monitoring Using a Spectrally Resolved Back Scattering Sensor JF - BrewingScience N2 - In the present work an optical sensor in combination with a spectrally resolved detection device for in-line particle-size-monitoring for quality control in beer production is presented. The principle relies on the size and wavelength dependent backscatter of growing particles in fluids. Measured interference structures of backscattered light are compared with calculated theoretical values, based on Mie-Theory, and fitted with a linear least square method to obtain particle size distributions. For this purpose, a broadband light source in combination with a process-CCD-spectrometer (charge ? coupled device spectrometer) and process adapted fiber optics are used. The goal is the development of an easy and flexible measurement device for in-line-monitoring of particle size. The presented device can be directly installed in product fill tubes or vessels, follows CIP- (cleaning in place) and removes the need of sample taking. A proof of concept and preliminary results, measuring protein precipitation, are presented. Y1 - 2018 SN - 1613-2041 VL - 71 IS - 5/6 SP - 49 EP - 55 PB - Fachverlag Hans Carl CY - Nürnberg ER - TY - JOUR A1 - Molinnus, Denise A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips JF - Electroanalysis N2 - The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor. Y1 - 2017 U6 - https://doi.org/10.1002/elan.201700208 SN - 1521-4109 VL - 29 IS - 8 SP - 1840 EP - 1849 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Heuermann, Holger A1 - Hillebrand, Jürgen A1 - Sadeghfam, Arash T1 - Novel Concept of a Digital SigmaDelta-PLL-Phase-Shift-Modulator / Hillebrand, Jürgen ; Sadeghfam, Arash ; Heuermann, Holger Y1 - 2008 SN - 978-3-8007-3086-5 N1 - Microwave Conference (GeMIC), 2008 German SP - 123 EP - 126 ER - TY - CHAP A1 - Platen, Johannes A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Microstructured Nanostructures – nanostructuring by means of conventional photolithography and layer-expansion technique N2 - A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures. KW - Biosensor KW - Nanostructuring KW - layer expansion KW - pattern-size reduction KW - self-aligned patterning Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1477 ER - TY - CHAP A1 - Herrmann, Ulf A1 - Kearney, D. A1 - Röger, M. A1 - Prahl, C. T1 - System performance measurements T2 - The Performance of Concentrated Solar Power (CSP) Systems : Modelling, Measurement and Assessment N2 - This chapter introduces performance and acceptance testing and describes state-of-the-art tools, methods, and instruments to assess the plant performance or realize plant acceptance testing. The status of the development of standards for performance assessment is given. KW - Performance measurement KW - Acceptance tests KW - Plant efficiency Y1 - 2017 SN - 978-0-08-100448-7 U6 - https://doi.org/https://doi.org/10.1016/B978-0-08-100447-0.00005-5 SP - 115 EP - 165 PB - Woodhead Publishing CY - Duxford ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Wagner, Torsten A1 - Poghossian, Arshak A1 - Miyamoto, K.I. A1 - Werner, C.F. A1 - Krause, S. A1 - Yoshinobu, T. T1 - Light-addressable potentiometric sensors for (bio-)chemical sensing and imaging T2 - Encyclopedia of Interfacial Chemistry: Surface Science and Electrochemistry. Vol. 7 Y1 - 2018 SN - 9780128097397 SP - 295 EP - 308 PB - Elsevier CY - Amsterdam ER -