TY - JOUR A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft JF - Bautechnische Zahlentafeln / Wendehorst, Reinhard ; Wetzell, Otto W. [Hrsg.] 32., vollst. aktualisierte Aufl. Y1 - 2007 SN - 978-3-8351-0055-8 SP - 1193 EP - 1289 PB - Teubner CY - Stuttgart ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft JF - Wendehorst Beispiele aus der Baupraxis / Wetzell, Otto W. ; Baumgartner, Herwig ; Wendehorst, Reinhard [Hrsg.]. Y1 - 2007 SN - 978-3-8351-0069-5 N1 - Kapitel 14 SP - 395 EP - 431 PB - Teubner CY - Wiesbaden ER - TY - JOUR A1 - Strohmeier, Andreas A1 - Eichholz, Günter T1 - Elimination von Phosphaten in technisch belüfteten Abwasserteichen / Eichholz, Günter; Strohmeier, Andreas JF - Wasser und Boden. 33 (1981), H. 5 Y1 - 1981 SN - 0043-0951 SP - 230 EP - 239 ER - TY - JOUR A1 - Thelen, Jan A1 - Paschmann, Hans A1 - Hamelmann, Dirk T1 - Zielsichere Herstellung und Anwendung von Flüssigboden JF - bi-UmweltBau Y1 - 2010 SN - 2509-2685 SP - 48 EP - 49 PB - bi-Medien-GmbH CY - Kiel ER - TY - JOUR A1 - Thiel, Dieter A1 - Döring, Bernd T1 - Dezentrale Raumklimatisierung durch die Fassade JF - TAB Technik am Bau Y1 - 2001 SN - 0341-2032 VL - Bd. 32 IS - H. 3 SP - 67 EP - 76 ER - TY - JOUR A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz T1 - Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenkühltürmen JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Zwangsbelüftete Nasskühltürme haben im Gegensatz zur Trockenkühlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßkühlung die spezifische Kühlleistung durch abgeführte Kondensationswärme höher als bei der Trockenkühlung. Hybridzellenkühltürme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftströme die Wasserdampf-Sättigungsgrenze nicht überschreitet. Durch das Mischungsverhältnis kann man den gewünschten Sättigungsgrad einstellen. Je dichter dieser an der Sättigungsgrenze liegt, desto höher ist die Kühlleistung. Der von unten zugeführte Luftstrom der Naßkühlung und der seitlich zugeführte trockene Abluftstrom müssen sehr gut durchmischt werden, um über den gesamten Austrittsquerschnitt des Kühlturms die Sättigungsgrenze nicht zu überschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. Über ein Raster von 10 mal 10 Punkten wurde die örtliche Temperaturverteilung ermittelt. Wärmebilanzen ergeben dann die Mischungsgüte in einer Ebene oberhalb der Zellenkrone. Während ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 % liegt erhöhen Einbauten den Trockenluftanteil auf 30 % bis über 40 %. Dabei wurde die Trockenluft auf jeder Kühlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftauslässe umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gewünschten Mittelwert zeigen Potential für die weitere Verbesserung der Einbauten. KW - Trockenkühlturm KW - Nasskühlturm KW - kombiniertes Verfahren KW - Mischen KW - Abluft Y1 - 2000 SN - 1436-5103 VL - 51 IS - 8 SP - 48 EP - 49 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Uibel, Thomas T1 - Untersuchungen zum Spaltverhalten von Holzschrauben. Teil 1 JF - Bauen mit Holz Y1 - 2016 SN - 0005-6545 N1 - gedruckte Zeitschrift in der Bereichsbibliothek Bayernallee IS - 10 SP - 40 EP - 42 PB - Rudolf Müller CY - Köln ER - TY - JOUR A1 - Valero, D. A1 - Bung, Daniel Bernhard A1 - Crookston, B. M. T1 - Closure to “Energy Dissipation of a Type III Basin under Design and Adverse Conditions for Stepped and Smooth Spillways” JF - Journal of Hydraulic Engineering Y1 - 2019 U6 - https://doi.org/10.1061/(ASCE)HY.1943-7900.0001669 VL - 146 IS - 2 PB - ASCE CY - Reston, Va. ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Development of the interfacial air layer in the non-aerated region of high-velocity spillway flows: Instabilities growth, entrapped air and influence on the self-aeration onset JF - International Journal of Multiphase Flow N2 - Self-aeration is traditionally explained by the water turbulent boundary layer outer edge intersection with the free surface. This paper presents a discussion on the commonly accepted hypothesis behind the computation of the critical point of self-aeration in spillway flows and a new formulation is proposed based on the existence of a developing air flow over the free surface. Upstream of the inception point of self-aeration, some surface roughening has been often reported in previous studies which consequently implies some entrapped air transport and air–water flows coupling. Such air flow is proven in this study by presenting measured air velocities and computing the air boundary layer thickness for a 1V:2H smooth chute flow. Additionally, the growth rate of free surface waves has been analysed by means of Ultrasonic Sensors measurements, obtaining also the entrapped air concentration. High-speed camera imaging has been used for qualitative study of the flow perturbations. Y1 - 2016 U6 - https://doi.org/10.1016/j.ijmultiphaseflow.2016.04.012 SN - 0301-9322 VL - 84 SP - 66 EP - 74 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Reformulating self-aeration in hydraulic structures: Turbulent growth of free surface perturbations leading to air entrainment JF - International Journal of Multiphase Flow N2 - A new formulation for the prediction of free surface dynamics related to the turbulence occurring nearby is proposed. This formulation, altogether with a breakup criterion, can be used to compute the inception of self-aeration in high velocity flows like those occurring in hydraulic structures. Assuming a simple perturbation geometry, a kinematic and a non-linear momentum-based dynamic equation are formulated and forces acting on a control volume are approximated. Limiting steepness is proposed as an adequate breakup criterion. Role of the velocity fluctuations normal to the free surface is shown to be the main turbulence quantity related to self-aeration and the role of the scales contained in the turbulence spectrum are depicted. Surface tension force is integrated accounting for large displacements by using differential geometry for the curvature estimation. Gravity and pressure effects are also contemplated in the proposed formulation. The obtained equations can be numerically integrated for each wavelength, hence resulting in different growth rates and allowing computation of the free surface roughness wavelength distribution. Application to a prototype scale spillway (at the Aviemore dam) revealed that most unstable wavelength was close to the Taylor lengthscale. Amplitude distributions have been also obtained observing different scaling for perturbations stabilized by gravity or surface tension. The proposed theoretical framework represents a new conceptualization of self-aeration which explains the characteristic rough surface at the non-aerated region as well as other previous experimental observations which remained unresolved for several decades. Y1 - 2018 U6 - https://doi.org/10.1016/j.ijmultiphaseflow.2017.12.011 SN - 0301-9322 VL - 100 SP - 127 EP - 142 PB - Elsevier CY - Amsterdam ER -