TY - JOUR A1 - Hillen, Walter A1 - Unglauben, F. A1 - Murdfield, M. T1 - Evaluation of two- and three-tier database connections for a java-based medical image viewer. Unglauben, F.; Hillen, W.; Murdfield, M. JF - Bildverarbeitung für die Medizin 2000 : Algorithmen - Systeme - Anwendungen ; proceedings des Workshops [Bildverarbeitung für die Medizin] vom 12. - 14. März 2000 in München / Alexander Horsch ... [Hrsg.] Y1 - 2000 SN - 3-540-67123-4 N1 - Inhaltsverzeichnis; Workshop Bildverarbeitung für die Medizin <2000, München> SP - 203 EP - 207 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Hillen, Walter A1 - Unglauben, F. A1 - Wirtz, G. T1 - Architectures and Modeling of Distributed Image Information Systems. Unglauben, F.; Hillen, W.; Wirtz, G. JF - Proceedings : July 14 - 18, 2002, Orlando, Florida, USA ; [jointly with the 8th International Conference on Information Systems Analysis and Synthesis (ISAS 2002)] / organized by IIIS, International Institute of Informatics and Systemics. Ed. by Nagib Callaos Y1 - 2002 SN - 9800781501 N1 - World Multiconference on Systemics, Cybernetics and Informatics ; (6, 2002, Orlando, Fla.) ; International Conference on Information Systems, Analysis and Synthesis ; (8, 2002, Orlando, Fla.) ; International Institute of Informatics and Systemics ; World Multiconference on Systemics, Cybernetics and Informatics ; (6 : ; 2002.07.14-18 : ; Orlando, Fla.) ; SCI 2002 ; (6 : ; 2002.07.14-18 : ; Orlando, Fla.) ; International Conference on Information Systems Analysis and Synthesis ; (8 : ; 2002.07.14-18 : ; Orlando, Fla.) ; ISAS 2002 ; (8 : ; 2002.07.14-18 : ; Orlando, Fla.) PB - IIIS CY - Orlando, Fla. ER - TY - JOUR A1 - Hillen, Walter A1 - Winterschlade, T. A1 - Krone, J. T1 - Erkennung lokaler Bildfehler in Röntgenbildverstärkern durch parallel arbeitende Bildrechner JF - Parallele Datenverarbeitung : Entwurfsmethoden, Bildverarbeitung, Simulation ; Workshop der Arbeitsgemeinschaft "Parallelverarbeitung an Fachhochschulen in NRW" am 19.6.1998 in Bochum / Jörg Krone ... (Hrsg.) Y1 - 1998 SN - 3-18-355310-4 N1 - Fortschritt-Berichte VDI : Reihe 10, Informatik, Kommunikationstechnik ; 553 SP - 88 EP - 94 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Hingley, Peter A1 - Dikta, Gerhard T1 - Finding a well performing box-jenkins forecasting model for annualised patent filings counts T2 - International Symposium on Forecasting, Thessaloniki, Greece, June 2019 Y1 - 2019 ER - TY - JOUR A1 - Hirschfeld, J. A. A1 - Lustfeld, H. A1 - Reißel, Martin A1 - Steffen, B. T1 - A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack JF - International Journal of Energy Research. 34 (2010), H. 3 Y1 - 2010 SN - 0363-907X SP - 293 EP - 301 ER - TY - JOUR A1 - Hirschfeld, J. A. A1 - Lustfeld, H. A1 - Reißel, Martin A1 - Steffen, B. T1 - Tomographic diagnostics of current distributions in a fuel cell stack JF - International Journal of Energy Research Y1 - 2010 SN - 0363-907X VL - 34 IS - 3 SP - 284 EP - 292 ER - TY - PAT A1 - Hofbauer, Peter A1 - Härtel, Günter A1 - Lösing, Karl-Heinrich A1 - Dorner, Robert A1 - Simonis, Rainer A1 - Schulte, Erasmus T1 - Brennstoffeinspritzsystem für Brennkraftmaschinen : Offenlegungsschrift DE 3833215 A1 ; Offenlegungstag: 28.12.89 N2 - Es wird ein Brennstoffeinspritzsystem für Brennkraftmaschinen vorgeschlagen, bei dem ein definiertes Teil eines fest vorgegebenen Brennstoffvolumens durch die Druckerhöhung innerhalb einer brennstoffeinschließenden Kammer eine definierte Brennstoffmenge über jeweils ein Rückschlagventil abgespritzt wird. Ein elektronisches Steuergerät berechnet die Dauer und/oder Intensität und gegebenenfalls die Impulsfolge eines zum Beispiel zur Verdampfung einer bestimmten Brennstoffmenge erforderlichen Laserimpulses. Das System kann für Ein- oder Mehrstelleinspritzung Verwendung finden. KW - Brennkraftmaschine KW - Brennstoffeinspritzsystem Y1 - 1989 PB - Deutsches Patent- und Markenamt CY - München ER - TY - JOUR A1 - Honarvarfard, Elham A1 - Gamella, Maria A1 - Channaveerappa, Devika A1 - Darie, Costel C. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny T1 - Electrochemically Stimulated Insulin Release from a Modified Graphene–functionalized Carbon Fiber Electrode JF - Electroanalysis N2 - A graphene-functionalized carbon fiber electrode was modified with adsorbed polyethylenimine to introduce amino functionalities and then with trigonelline and 4-carboxyphenylboronic acid covalently bound to the amino groups. The trigonelline species containing quarterized pyridine groups produced positive charge on the electrode surface regardless of the pH value, while the phenylboronic acid species were neutral below pH 8 and negatively charged above pH 9 (note that their pKa=8.4). The total charge on the monolayer-modified electrode was positive at the neutral pH and negative at pH > 9. Note that 4-carboxyphenylboronic acid was attached to the electrode surface in molar excess to trigonelline, thus allowing the negative charge to dominate on the electrode surface at basic pH. Negatively charged fluorescent dye-labeled insulin (insulin-FITC) was loaded on the modified electrode surface at pH 7.0 due to its electrostatic attraction to the positively charged interface. The local pH in close vicinity to the electrode surface was increased to ca. 9–10 due to consumption of H+ ions upon electrochemical reduction of oxygen proceeding at the potential of −1.0 V (vs. Ag/AgCl) applied on the modified electrode. The process resulted in recharging of the electrode surface to the negative value due to the formation of the negative charge on the phenylboronic acid groups, thus resulting in the electrostatic repulsion of insulin-FITC and stimulating its release from the electrode surface. The insulin release was characterized by fluorescence spectroscopy (using the FITC-labeled insulin), by electrochemical measurements on an iridium oxide, IrOx, electrode and by mass spectrometry. The graphene-functionalized carbon fiber electrode demonstrated significant advantages in the signal-stimulated insulin release comparing with the carbon fiber electrode without the graphene species. Y1 - 2017 U6 - http://dx.doi.org/10.1002/elan.201700095 SN - 1521-4109 VL - 29 IS - 6 SP - 1543 EP - 1553 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Honarvarfard, Elham A1 - Gamella, Maria A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny T1 - An enzyme-based reversible Controlled NOT (CNOT) logic gate operating on a semiconductor transducer JF - Applied Materials Today N2 - An enzyme-based biocatalytic system mimicking operation of a logically reversible Controlled NOT (CNOT) gate has been interfaced with semiconductor electronic transducers. Electrolyte–insulator–semiconductor (EIS) structures have been used to transduce chemical changes produced by the enzyme system to an electronically readable capacitive output signal using field-effect features of the EIS device. Two enzymes, urease and esterase, were immobilized on the insulating interface of EIS structure producing local pH changes performing XOR logic operation controlled by various combinations of the input signals represented by urea and ethyl butyrate. Another EIS transducer was functionalized with esterase only, thus performing Identity (ID) logic operation for the ethyl butyrate input. Both semiconductor devices assembled in parallel operated as a logically reversible CNOT gate. The present system, despite its simplicity, demonstrated for the first time logically reversible function of the enzyme system transduced electronically with the semiconductor devices. The biomolecular realization of a CNOT gate interfaced with semiconductors is promising for integration into complex biomolecular networks and future biosensor/biomedical applications. KW - Electrolyte–insulator–semiconductor KW - Capacitive field-effect KW - CNOT KW - XOR KW - Enzyme logic gate Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.apmt.2017.08.003 SN - 2352-9407 VL - 9 SP - 266 EP - 270 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Horbach, Andreas A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Modelling of compressible and orthotropic surgical mesh implants based on optical deformation measurement JF - Journal of the mechanical behavior of biomedical materials Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jmbbm.2017.06.012 SN - 1751-6161 VL - 74 SP - 400 EP - 410 PB - Elsevier CY - Amsterdam ER -