TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Poghossian, Arshak T1 - Markierungsfreie DNA-Detektion mit Silizium-Feldeffektsensoren – Messeffekte oder Artefakte? T2 - Sensoren und Mess-Systeme 2006 : Vorträge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau Y1 - 2006 SN - 3-8007-2939-3 SP - 443 EP - 446 PB - VDE Verl. CY - Berlin ER - TY - BOOK A1 - Schelthoff, Christof T1 - Mathematik im Bachelor- und Diplomstudium für Bio- und Chemieingenieure Y1 - 2006 SN - 978-3-8322-5309-7 PB - Shaker CY - Aachen ER - TY - CHAP A1 - Sakthivel, Mariappan A1 - Weppner, Werner T1 - Response behaviour of a hydrogen sensor based on ionic conducting polymer-metal interfaces prepared by the chemical reduction method N2 - A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX. KW - Biosensor KW - Hydrogen sensor KW - amperometric sensor KW - porous Pt electrode KW - chemical reduction method Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1399 ER - TY - GEN A1 - Rongen, Heinz A1 - Ziemons, Karl A1 - Schiek, Michael A1 - Tass, Alexander T1 - Vorrichtung zur Messung biomedizinischer Daten eines Probanden und Verfahren zur Simulation des Probanden mit in Echtzeit verarbeiteten Daten T1 - Device for measuring biomedical data from a testee and method for stimulating the testee with data processed in real-time N2 - Die Erfindung betrifft eine Vorrichtung zur Messung biomedizinischer Daten eines Probanden, mit einem Messsystem zur Erhebung der Daten sowie einer ersten Hardware-Komponente zur Aufzeichnung der Daten. In einer Verbindungsleitung zur Übertragung der Daten vom Messsystem zur ersten Hardware-Komponente zur Aufzeichnung der Daten ist erfindungsgemäss ein Mittel zur galvanischen Auftrennung der Daten angeordnet. Auf diese Weise ist wenigstens die Duplizierung der Daten für Datenverarbeitungszwecke gewährleistet. Die auf diese Weise verarbeiteten Daten werden für ein Verfahren zur Echtzeit-Stimulation eines Probanden genutzt. Y1 - 2006 N1 - Auch veröffentlicht als EP2007276 ; US2009069662 ; US8301222 ; JP2009535071 ; WO2007118443 ; AT 533401 SP - 1 EP - 12 ER - TY - CHAP A1 - Rabner, Arthur A1 - Shacham, Yosi T1 - A concept for a sensitive micro total analysis system for high throughput fluorescence imaging N2 - This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background. KW - Biosensor KW - Fluorescence KW - imaging KW - lab-on-chip KW - fluidic KW - lenslet array KW - LED chip KW - image sensor KW - biosensor Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1456 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Silicon-based chemical and biological field-effect sensors T2 - Encyclopedia of Sensors. Vol. 9 S - Sk Y1 - 2006 SN - 1-58883-065-9 SP - 463 EP - 534 PB - ASP, American Scientific Publ. CY - Stevenson Ranch, Calif. ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schumacher, Kerstin A1 - Kloock, Joachim P. A1 - Rosenkranz, Christian A1 - Schultze, Joachim W. A1 - Müller-Veggian, Mattea A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell N2 - A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors. KW - Biosensor KW - Biosensorik KW - ISFET KW - Wafer KW - ISFET KW - wafer-level testing KW - capillary micro-droplet cell Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1259 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Platen, J. A1 - Schöning, Michael Josef T1 - Field-effect sensors with charged macromolecules – from micro towards nano aspects T2 - Biochemical Sensing Utilisation of Micro-and Nanotechnologies, Warschau, Nov. 2005 : Lecture Notes of the ICB Seminar / ed.: M. Mascini, W. Torbicz Y1 - 2006 SP - 74 EP - 81 PB - Polish Academy Sciences Press CY - Warsaw ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Sakkari, M. A1 - Kassab, T. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Field-effect sensors for monitoring the layer-by-layer adsorption of charged macromolecules JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 163 EP - 170 ER - TY - CHAP A1 - Platen, Johannes A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Microstructured Nanostructures – nanostructuring by means of conventional photolithography and layer-expansion technique N2 - A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures. KW - Biosensor KW - Nanostructuring KW - layer expansion KW - pattern-size reduction KW - self-aligned patterning Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1477 ER -