TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm). Y1 - 2003 SN - 1082-3654 SP - 682 EP - 686 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - IEEE Transactions on Nuclear Science N2 - Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 5 SP - 1428 EP - 1432 ER - TY - JOUR A1 - Heinrich, U. A1 - Blum, A. A1 - Bussmann, N. A1 - Engels, R. A1 - Kemmerling, G. A1 - Weber, S. A1 - Ziemons, Karl T1 - Statistical studies on the light output and energy resolution of small LSO single crystals with different surface treatments combined with various reflector materials JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The optimization of light output and energy resolution of scintillators is of special interest for the development of high resolution and high sensitivity PET. The aim of this work is to obtain statistically reliable results concerning optimal surface treatment of scintillation crystals and the selection of reflector material. For this purpose, raw, mechanically polished and etched LSO crystals (size 2×2×10 mm3) were combined with various reflector materials (Teflon tape, Teflon matrix, BaSO4) and exposed to a 22Na source. In order to ensure the statistical reliability of the results, groups of 10 LSO crystals each were measured for all combinations of surface treatment and reflector material. Using no reflector material the light output increased up to 551±35% by mechanical polishing the surface compared to 100±5% for raw crystals. Etching the surface increased the light output to 441±29%. The untreated crystals had an energy resolution of 24.6±4.0%. By mechanical polishing the surface it was possible to achieve an energy resolution of 13.2±0.8%, by etching of 14.8±0.7%. In combination with BaSO4 as reflector material the maximum increase of light output has been established to 932±57% for mechanically polished and 895±61% for etched crystals. The combination with BaSO4 also caused the best improvement of the energy resolution up to 11.6±0.2% for mechanically polished and 12.2±0.3% for etched crystals. Relating to the light output there was no significant statistical difference between the two surface treatments in combination with BaSO4. In contrast to this, the statistical results of the energy resolution have shown the combination of mechanical polishing and BaSO4 as the optimum. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 60 EP - 66 ER - TY - JOUR A1 - Hautzel, H. A1 - Taylor, J. G. A1 - Krause, B. J. A1 - Schmitz, N. A1 - Tellmann, L. A1 - Ziemons, Karl A1 - Shah, N. J. A1 - Herzog, H. A1 - Müller-Gärtner, H.-W. T1 - The motion aftereffect: more than area V5/MT? Evidence from 15O-butanol PET studies JF - Brain Research N2 - The motion aftereffect is a perceptual phenomenon which has been extensively investigated both psychologically and physiologically. Neuroimaging techniques have recently demonstrated that area V5/MT is activated during the perception of this illusion. The aim of this study was to test the hypothesis if a more broadly distributed network of brain regions subserves the motion aftereffect. To identify the neuronal structures involved in the perception of the motion aftereffect, regional cerebral blood flow (rCBF) measurements with positron emission tomography were performed in six normal volunteers. Data were analysed using SPM96. The motion-sensitive visual areas including area V5/MT were activated in both hemispheres. Additionally, the lateral parietal cortex bilaterally, the right dorsolateral prefrontal cortex, the anterior cingulate cortex and the left cerebellum showed significant increases in rCBF values during the experience of the waterfall illusion. In a further reference condition with identical attentional demand but no perception of a motion aftereffect elevated rCBF were found in these regions as well. In conclusion, our findings support the notion that the perceptual illusion of motion arises exclusively in the motion-sensitive visual area V5/MT. In addition, a more widespread network of brain regions including the prefrontal and parietal cortex is activated during the waterfall illusion which represents a non-motion aftereffect-specific subset of brain areas but is involved in more basic attentional processing and cognition. Y1 - 2001 SN - 0006-8993 VL - 892 IS - 2 SP - 281 EP - 292 ER - TY - JOUR A1 - Grießmeier, M. A1 - Sonnenberg, F. A1 - Weckesser, M. A1 - Ziemons, Karl A1 - Langen, K.-J. A1 - Müller-Gärtner, H. W. T1 - Improvement of SPECT quantification in small brain structures by using experiment based recovery-coefficient corrections JF - European Journal of Nuclear Medicine Y1 - 1996 SN - 1619-7089 N1 - Abstracts ; PSu827 VL - 23 IS - 9 SP - 1238 EP - 1238 ER - TY - JOUR A1 - Garibaldi, F. A1 - Beging, Stefan A1 - Canese, R. A1 - Carpinelli, G. A1 - Clinthorne, N. A1 - Colilli, S. A1 - Cosentino, L. A1 - Finocchiaro, P. A1 - Giuliani, F. A1 - Gricia, M. A1 - Lucentini, M. A1 - Majewski, S. A1 - Monno, E. A1 - Musico, P. A1 - Santavenere, F. A1 - Tödter, J. A1 - Wegener, Hans-Peter A1 - Ziemons, Karl T1 - A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer JF - European Physical Journal Plus Y1 - 2017 U6 - http://dx.doi.org/10.1140/epjp/i2017-11662-x SN - 2190-5444 VL - 132 IS - 9 PB - Springer CY - Berlin ER - TY - JOUR A1 - Fink, G. R. A1 - Marshall, J. C. A1 - Shah, N. J. A1 - Weiss, P.H. A1 - Halligan, P. W. A1 - Grosse-Ruyken, M. A1 - Ziemons, Karl A1 - Zilles, K. A1 - Freund, H. J. T1 - Line bisection judgments implicate right parietal cortex and cerebellum as assessed by fMRI JF - Neurology Y1 - 2000 SN - 1526-632X VL - 54 IS - 6 SP - 1324 EP - 1331 ER - TY - JOUR A1 - Erki, I. A1 - Kleines, H. A1 - Ziemons, Karl A1 - Zwoll, K. ED - Lehmann, Thomas T1 - Interaktives System zur Darstellung funktionaler Bilddaten JF - Bildverarbeitung für die Medizin : Algorithmen - Systeme - Anwendungen Y1 - 1997 SN - 3-86073-519-5 N1 - Proceedings des Aachener Workshops am 8. u. 9. November 1996 ; PP_002 Posterpräsentation SP - 249 EP - 254 PB - Verl. der. Augustinus-Buchh. CY - Aachen ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Choi, Chang-Hoon A1 - Felder, Tim A1 - Felder, Jörg A1 - Tellmann, Lutz A1 - Hong, Suk-Min A1 - Wegener, Hans-Peter A1 - Shah, N Jon A1 - Ziemons, Karl T1 - Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate JF - Physics in Medicine & Biology N2 - Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future. Y1 - 2020 U6 - http://dx.doi.org/10.1088/1361-6560/ab87f8 SN - 0031-9155 VL - 65 IS - 11 PB - IOP CY - Bristol ER -