TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Cherstvy, A. A1 - Schöning, Michael Josef T1 - Possibilities and limitations of label-free detection of DNA hybridization with field-effect based devices JF - Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale]. Y1 - 2004 SN - 88-7621-282-5 N1 - Eurosensors ; (18, 2004, Roma) SP - 173 EP - 176 CY - Roma ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ui, Y. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Potentiometric imaging in a microfluidic channel JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 998 EP - 999 ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Mourzina, Y. A1 - Schubert, J. A1 - Ermelenko, Y. A1 - Schöning, Michael Josef T1 - Pulsed laser deposition: A tool for fabricating thin-film microsensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1032 EP - 1033 ER - TY - JOUR A1 - Digel, Ilya A1 - Trzewik, Jürgen A1 - Demirci, Taylan A1 - Temiz Artmann, Aysegül T1 - Response of fibroblasts to cyclic mechanical stress : a proteome approach / Digel, I. ; Trzewik, J. ; Demirci, T. ; Temiz Artmann, A. ; Artmann, G. M. JF - Biomedizinische Technik. 49 (2004), H. Erg.-Bd. 2 Y1 - 2004 SN - 0932-4666 SP - 1042 EP - 1043 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Vilser, Walthatd A1 - Nagel, Edgar A1 - Lanzl, Ines M. T1 - Retinal vessel reaction in response to chromatic flickering light / Kotliar, Konstantin E. ; Vilser, Walthard ; Nagel, Edgar ; Lanzl, Ines M. JF - Graefe's Archive for Clinical and Experimental Ophthalmology. 242 (2004), H. 5 Y1 - 2004 SN - 1435-702X SP - 377 EP - 392 PB - - ER - TY - JOUR A1 - Dikta, Gerhard A1 - Degenring, D. A1 - Froemmel, C. A1 - Takors, R. T1 - Sensitivity analysis for the reduction of complex metabolism models / Degenring, D. ; Froemmel, C. ; Dikta, G.; Takors, R. JF - Journal of Process Control. 14 (2004) Y1 - 2004 SN - 0959-1524 SP - 729 EP - 745 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. A1 - Knobbe, D.-T. A1 - Räde, J. A1 - Keusgen, M. T1 - Silicon field-effect biosensor for cyanide detection JF - Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors Y1 - 2004 N1 - Chemical sensors ; 20.2004 Suppl. B. IMCS ; (10, 2004, Tsukuba) ; International Meeting on Chemical Sensors ; (10 : ; 2004.07.11-14 : ; Tsukuba) SP - 98 EP - 99 PB - Japan Association of Chemical Sensors CY - Fukuoka ER - TY - JOUR A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Strategies for biosensoric detection of potential drugs in nature JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1004 EP - 1005 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER -