TY - CHAP A1 - Loeb, Horst W. A1 - Schartner, Karl-Heinz A1 - Dachwald, Bernd A1 - Ohndorf, Andreas A1 - Seboldt, Wolfgang T1 - An Interstellar – Heliopause mission using a combination of solar/radioisotope electric propulsion T2 - Presented at the 32nd International Electric Propulsion Conference N2 - There is common agreement within the scientific community that in order to understand our local galactic environment it will be necessary to send a spacecraft into the region beyond the solar wind termination shock. Considering distances of 200 AU for a new mission, one needs a spacecraft travelling at a speed of close to 10 AU/yr in order to keep the mission duration in the range of less than 25 yrs, a transfer time postulated by ESA.Two propulsion options for the mission have been proposed and discussed so far: the solar sail propulsion and the ballistic/radioisotope electric propulsion. As a further alternative, we here investigate a combination of solar-electric propulsion and radioisotope-electric propulsion. The solar-electric propulsion stage consists of six 22 cm diameter “RIT-22”ion thrusters working with a high specific impulse of 7377 s corresponding to a positive grid voltage of 5 kV. Solar power of 53 kW BOM is provided by a light-weight solar array. The REP-stage consists of four space-proven 10 cm diameter “RIT-10” ion thrusters that will be operating one after the other for 9 yrs in total. Four advanced radioisotope generators provide 648 W at BOM. The scientific instrument package is oriented at earlier studies. For its mass and electric power requirement 35 kg and 35 W are assessed, respectively. Optimized trajectory calculations, treated in a separate contribution, are based on our “InTrance” method.The program yields a burn out of the REP stage in a distance of 79.6 AU for a usage of 154 kg of Xe propellant. With a C3 = 45,1 (km/s)2 a heliocentric probe velocity of 10 AU/yr is reached at this distance, provided a close Jupiter gravity assist adds a velocity increment of 2.7 AU/yr. A transfer time of 23.8 yrs results for this scenario requiring about 450 kg Xe for the SEP stage, jettisoned at 3 AU. We interpret the SEP/REP propulsion as a competing alternative to solar sail and ballistic/REP propulsion. Omiting a Jupiter fly-by even allows more launch flexibility, leaving the mission duration in the range of the ESA specification. Y1 - 2011 N1 - 32nd International Electric Propulsion Conference, 11-15 September. Wiesbaden, Germany SP - 1 EP - 7 ER - TY - CHAP A1 - Alhwarin, Faraj A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - An Optimized Method for 3D Body Scanning Applications Based on KinectFusion T2 - Communications in Computer and Information Science Y1 - 2019 U6 - http://dx.doi.org/10.1007/978-3-030-29196-9_6 SN - 1865-0929 N1 - 11th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2018; Funchal; Portugal; 19 January 2018 through 21 January 2018 VL - 1024 SP - 100 EP - 113 PB - Springer ER - TY - CHAP A1 - Heuermann, Holger A1 - Sadeghfam, Arash T1 - Analog Amplitude-Locked Loop Circuit to Support RF Energy Solutions T2 - IEEE MTT-S International Microwave Symposium Digest Y1 - 2016 SN - 978-150900698-4 U6 - http://dx.doi.org/10.1109/MWSYM.2016.7540092 ER - TY - CHAP A1 - Vaeßen, Christiane A1 - Alexopoulos, Spiros A1 - Kluczka, Sven A1 - Sattler, Johannes Christoph A1 - Roeb, M. A1 - Neises, M. A1 - Abdellatif, T. T1 - Analyse der Verfahren zur solaren Methanolproduktion aus CO2 T2 - Forschung und Entwicklung für solarthermische Kraftwerke : 14. Kölner Sonnenkolloquium Mittwoch, 13. Juli 2011, im Auditorium des Campus Jülich der FH Aachen : Kurzfassungen der Vorträge und Poster Y1 - 2011 SP - 2 S. PB - DLR CY - Köln ER - TY - CHAP A1 - Vedral, Andreas A1 - Wollert, Jörg T1 - Analyse und Definition der Qualität von Funkkanälen für die Echtzeitübertragung T2 - Funkgestützte Kommunikation in der industriellen Automatisierungstechnik : Tagung Düsseldorf, 4. und 5. Mai 2004. (VDI-Berichte ; 1843) Y1 - 2004 SN - 3-18-091843-8 SP - 113 EP - 122 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Hoffmann, Marc T1 - Analyse und Visualisierung von zeitbezogenen Daten im Raum – Beispiele aus Hydrologie und Wasserwirtschaft N2 - Dipl.-Ing Marc Hoffmann - Kisters AG, Aachen. 13 S. (S. 32-44). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Zahlreiche Folien, Grafiken und Praxisbeispiele KW - Visualisierung KW - Hydrologie KW - Wasserwirtschaft Y1 - 2009 ER - TY - CHAP A1 - Wulfhorst, Helene A1 - Merseburg, Johannes A1 - Tippkötter, Nils T1 - Analyse von Lignocellulose mittels dynamischer Differenzkalorimetrie und Infrarot – Spektrometrie T2 - 12. Dresdner Sensor-Symposium 2015 2015-12-07 - 2015-12-09 Y1 - 2015 SN - 978-3-9813484-9-1 U6 - http://dx.doi.org/10.5162/12dss2015/P6.2 SP - 210 EP - 215 ER - TY - CHAP A1 - Gedle, Yibekal A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Schmitz, Pascal A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José A1 - Mahdi, Zahra A1 - Caminos, Ricardo Alexander Chico A1 - Dersch, Jürgen T1 - Analysis of an integrated CSP-PV hybrid power plant T2 - SolarPACES 2020 N2 - In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] – [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution. KW - Hybrid energy system KW - Power plants KW - Electricity generation KW - Energy storage KW - Associated liquids Y1 - 2022 SN - 978-0-7354-4195-8 U6 - http://dx.doi.org/10.1063/5.0086236 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - 26th International Conference on Concentrating Solar Power and Chemical Energy Systems 28 September–2 October 2020 Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Rosin, J. A1 - Mykoniou, K. A1 - Butenweg, Christoph T1 - Analysis Of Base Isolated Liquid Storage Tanks With 3D Fsi-Analysis As Well As Simplified Approaches T2 - 16th World Conference on Earthquake Engineering, 16WCEE 2017 Santiago Chile, January 9th to 13th 2017 N2 - Tanks are preferably designed, for cost-saving reasons, as circular, cylindrical, thin-walled shells. In case of seismic excitation, these constructions are highly vulnerable to stability failures. An earthquake-resistant design of rigidly supported tanks for high seismic loading demands, however, uneconomic wall thicknesses. A cost-effective alternative can be provided by base isolation systems. In this paper, a simplified seismic design procedure for base isolated tanks is introduced, by appropriately modifying the standard mechanical model for flexible, rigidly supported tanks. The non-linear behavior of conventional base isolation systems becomes an integral part of a proposed simplified process, which enables the assessment of the reduced hydrodynamic forces acting on the tank walls and the corresponding stress distribution. The impulsive and convective actions of the liquid are taken into account. The validity of this approach is evaluated by employing a non-linear fluid-structure interaction algorithm of finite element method. Special focus is placed on the boundary conditions imposed from the base isolation and the resulting hydrodynamic pressures. Both horizontal and vertical component of ground motion are considered in order to study the principal effects of the base isolation on the pressure distribution of the tank walls. The induced rocking effects associated with elastomeric bearings are discussed. The results manifest that base isolated tanks can be designed for seismic loads by means of the proposed procedure with sufficient accuracy, allowing to dispense with numerically expensive techniques. KW - liquid storage tank KW - seismic isolation KW - elastomeric bearing KW - friction pendulum bearing KW - simplified approach Y1 - 2017 N1 - Paper No 2246 SP - 1 EP - 14 PB - Chilean Association on Seismology and Earthquake Engineering (ACHISINA) ER - TY - CHAP A1 - Pfaff, Raphael T1 - Analysis of Big Data Streams to obtain Braking Reliability Information for Train Protection systems T2 - Asia-Pacific Conference of the Prognostics and Health Management Society Y1 - 2017 N1 - Asia-Pacific Conference of the Prognostics and Health Management Society, Jeju, Korea 2017 SP - 1 EP - 7 ER -