TY - JOUR A1 - Wu, Chunsheng A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Bäcker, Matthias A1 - Schöning, Michael Josef T1 - Label-free electrical detection of DNA with a multi-spot LAPS: First step towards light-addressable DNA chips JF - Physica status solidi A : Applications and materials science N2 - A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent–voltage (I–V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I–V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge. Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201330442 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1423 EP - 1428 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Label-free sensing of biomolecules with field-effect devices for clinical applications JF - Electroanalysis N2 - Among the variety of transducer concepts proposed for label-free detection of biomolecules, the semiconductor field-effect device (FED) is one of the most attractive platforms. As medical techniques continue to progress towards diagnostic and therapies based on biomarkers, the ability of FEDs for a label-free, fast and real-time detection of multiple pathogenic and physiologically relevant molecules with high specificity and sensitivity offers very promising prospects for their application in point-of-care and personalized medicine for an early diagnosis and treatment of diseases. The presented paper reviews recent advances and current trends in research and development of different FEDs for label-free, direct electrical detection of charged biomolecules by their intrinsic molecular charge. The authors are mainly focusing on the detection of the DNA hybridization event, antibody-antigen affinity reaction as well as clinically relevant biomolecules such as cardiac and cancer biomarkers. Y1 - 2014 U6 - https://doi.org/10.1002/elan.201400073 SN - 1521-4109 (E-Journal); 1040-0397 (Print) VL - 26 IS - 6 SP - 1197 EP - 1213 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hafner, David A1 - Demetz, Oliver A1 - Weickert, Joachim A1 - Reißel, Martin T1 - Mathematical Foundations and Generalisations of the Census Transform for Robust Optic Flow Computation JF - Journal of Mathematical Imaging and Vision Y1 - 2014 U6 - https://doi.org/10.1007/s10851-014-0529-9 SN - 1573-7683 (Online) N1 - Springer Online First (ohne Seitenang. und Heftzuteilung) PB - Springer CY - New York ER - TY - JOUR A1 - Martin-Gonzalez, Anabel A1 - Kotliar, Konstantin A1 - Rios-Martinez, Jorge A1 - Lanzl, Ines A1 - Navab, Nassir T1 - Mediated-reality magnification for macular degeneration rehabilitation JF - Journal of Modern Optics Y1 - 2014 U6 - https://doi.org/10.1080/09500340.2014.936110 SN - 1362-3044 VL - 61 IS - 17 SP - 1400 EP - 1408 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Leinhos, Marcel A1 - Schusser, Sebastian A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Micromachined multi-parameter sensor chip for the control of polymer-degradation medium JF - Physica Status Solidi (A) : special issue on engineering and functional interfaces N2 - It is well known that the degradation environment can strongly influence the biodegradability and kinetics of biodegradation processes of polymers. Therefore, besides the monitoring of the degradation process, it is also necessary to control the medium in which the degradation takes place. In this work, a micromachined multi-parameter sensor chip for the control of the polymer-degradation medium has been developed. The chip combines a capacitive field-effect pH sensor, a four-electrode electrolyte-conductivity sensor and a thin-film Pt-temperature sensor. The results of characterization of individual sensors are presented. In addition, the multi-parameter sensor chip together with an impedimetric polymer-degradation sensor was simultaneously characterized in degradation solutions with different pH and electrolyte conductivity. The obtained results demonstrate the feasibility of the multi-parameter sensor chip for the control of the polymer-degradation medium. Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201330364 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1346 EP - 1351 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Turaliyeva, M. A1 - Yeshibaev, A. A1 - Digel, Ilya A1 - Elibayeva, G. A1 - Sydykova, A. A1 - Uspabayeva, A. A1 - Dosybayeva, G. A1 - Zhylysbayeva, A. A1 - Lakhanova, K. T1 - Molecular-genetic identification of emerged novel invasive pathogens of Asiatic Elm Ulmus pumila L JF - Life science journal N2 - The dwarf elm Ulmus pumila L. (Ulmaceae) is one of indigenous species of flora in Kazakhstan and forms a basis of dendroflora in virtually all settlements of the region. In the past decade, multiple outbreaks of previously unknown diseases of the small-leaved elm have been registered. In our study, by the molecular-genetic analysis it was found that the pathogens responsible for the outbreaks are microfungi belonging to the genus Fusarium – F. solani and F. oxysporum. The nucleotide sequences (ITS regions) isolated from the diseased trees showed very high similarity with the GenBank control numbers EU625403.1 and FJ478128.1 (100.0 and 99.0 % respectively). Oncoming research will focus on the search of natural microbial antagonists of the discovered phytopathogens. Y1 - 2014 U6 - https://doi.org/10.7537/marslsj1105s14.33 SN - 1097-8135 VL - 11 IS - Spec. iss. 5s SP - 171 EP - 175 PB - Marsland Press CY - New York ER - TY - JOUR A1 - Fuest, Matthias A1 - Kotliar, Konstantin A1 - Walter, Peter A1 - Plange, Niklas T1 - Monitoring intraocular pressure changes after intravitreal Ranibizumab injection using rebound tonometry JF - Ophthalmic and physiological optics Y1 - 2014 U6 - https://doi.org/10.1111/opo.12134 SN - 1475-1313 (E-Journal); 0275-5408 (Print) N1 - Special Issue: The Ageing Visual System VL - 34 IS - 4 SP - 438 EP - 444 PB - Wiley-Blackwell CY - Oxford ER - TY - CHAP A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Buniatyan, V. A1 - Schöning, Michael Josef T1 - Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 5 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Sawada, Kazuaki A1 - Nakazawa, Hirokazu A1 - Takenaga, Shoko A1 - Hizawa, Takeshi A1 - Futagawa, Masato A1 - Dasai, Fumihiro A1 - Sakurai, Takashi A1 - Okumura, Koichi A1 - Hattori, Toshiaki A1 - Ishida, Makoto T1 - Multimodal bioimage sensor JF - IEICE transactions on fundamentals of electronics, communidations and computer sciences N2 - To visualize the biochemical distribution two-dimensionally, we invented a solid-state-type ion image sensor that indicates the chemical activity of solutions and cells. The device, which consists of a CCD array covered with a functionalized membrane to detect charge accumulation, is highly sensitive to changes in the concentration and two-dimensional distribution of ions and biomaterials. Y1 - 2014 U6 - https://doi.org/10.1587/transfun.E97.A.726 SN - 0916-8508 (Print) ; 1745-1337 (Online) VL - E97-A (2014) IS - 3 SP - 726 EP - 733 PB - IEICE CY - Tokyo ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Kerroumi, Iman A1 - Schusser, Sebastian A1 - Bäcker, Matthias A1 - Zander, Willi A1 - Schubert, Jürgen A1 - Buniatyan, Vahe V. A1 - Martirosyan, Norayr W. A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Multiparameter sensor chip with Barium Strontium Titanate as multipurpose material JF - Electroanalysis N2 - It is well known that biochemical and biotechnological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have to be monitored or controlled in order to guarantee a stable process operation, optimization and high yield. In this work, a sensor chip for the multiparameter detection of three physico-chemical parameters such as electrolyte conductivity, pH and temperature is realized using barium strontium titanate (BST) as multipurpose material. The chip integrates a capacitively coupled four-electrode electrolyte-conductivity sensor, a capacitive field-effect pH sensor and a thin-film Pt-temperature sensor. Due to the multifunctional properties of BST, it is utilized as final outermost coating layer of the processed sensor chip and serves as passivation and protection layer as well as pH-sensitive transducer material at the same time. The results of testing of the individual sensors of the developed multiparameter sensor chip are presented. In addition, a quasi-simultaneous multiparameter characterization of the sensor chip in buffer solutions with different pH value and electrolyte conductivity is performed. To study the sensor behavior and the suitability of BST as multifunctional material under harsh environmental conditions, the sensor chip was exemplarily tested in a biogas digestate. Y1 - 2014 U6 - https://doi.org/10.1002/elan.201400076 SN - 1521-4109 (E-Journal); 1040-0397 (Print) VL - 26 IS - 5 SP - 980 EP - 987 PB - Wiley-VCH CY - Weinheim ER -