TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Pedraza, A. M. A1 - Gandhi, D. A1 - Ingebrandt, S. A1 - Moritz, W. A1 - Schöning, Michael Josef T1 - An array of field-effect nanoplate SOI capacitors for (bio-)chemical sensing JF - Biosensors and Bioelectronics. 26 (2011), H. 6 Y1 - 2011 SN - 0956-5663 SP - 3023 EP - 3028 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Welden, Rene A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - An Array of On-Chip Integrated, Individually Addressable Capacitive Field-Effect Sensors with Control Gate: Design and Modelling JF - Sensors N2 - The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed. KW - equivalent circuit KW - multianalyte detection KW - control gate KW - on-chip integrated addressable EISCAP sensors KW - capacitive field-effect sensor Y1 - 2021 U6 - http://dx.doi.org/10.3390/s21186161 SN - 1424-8220 N1 - This article belongs to the Special Issue "Field-Effect Sensors: From pH Sensing to Biosensing" VL - 21 IS - 18 SP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Spiess, Elmar A1 - Wilfried, Reichardt A1 - Alvarez, Gerardo A1 - Gottrup, Marcus A1 - Öhlschläger, Peter T1 - An Artificial PAP Gene Breaks Self-tolerance and Promotes Tumor Regression in the TRAMP Model for Prostate Carcinoma JF - Molecular Therapy Y1 - 2011 SN - 1525-0016 VL - 20 IS - 3 SP - 555 EP - 564 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Tippkötter, Nils A1 - Roikaew, W. A1 - Ulber, R. T1 - An automated pilot plant for the bioengineering processing of concentrated whey T2 - European BioPerspectives : in cooperation with BIOTECHNICA 2008 : 7 - 9 October 2008 Hannover, Germany ; book of abstracts ; abstracts, poster programme Y1 - 2008 SP - 98 PB - Dechema CY - Frankfurt am Main ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - An Edge-Based Smoothed Finite Element Method for Primal-Dual Shakedown Analysis of Structures Under Uncertainties JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 89 EP - 102 PB - Springer CY - Dordrecht ER - TY - CHAP A1 - Becker, Jörg A1 - Bergener, Philipp A1 - Breuker, Dominic A1 - Delfmann, Patrick A1 - Eggert, Mathias T1 - An Efficient Business Process Compliance Checking Approach T2 - Governance and Sustainability in Information Systems. Managing the Transfer and Diffusion of IT : IFIP WG 8.6 International Working Conference, Hamburg, Germany, September 22-24, 2011. Proceedings Y1 - 2011 U6 - http://dx.doi.org/10.1007/978-3-642-24148-2_19 SP - 282 EP - 287 PB - Springer CY - Berlin, Heidelberg ER - TY - CHAP A1 - Alhwarin, Faraj A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - An Efficient Hashing Algorithm for NN Problem in HD Spaces T2 - Lecture Notes in Computer Science Y1 - 2019 SN - 978-303005498-4 U6 - http://dx.doi.org/10.1007/978-3-030-05499-1_6 N1 - 7th International Conference on Pattern Recognition Applications and Methods, ICPRAM 2018; Funchal; Portugal; 16 January 2018 through 18 January 2018; Code 222779 SP - 101 EP - 115 ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Kruszona, Stefan A1 - Orzada, Stephan A1 - Schaefer, Lena C. A1 - Theysohn, Jens M. A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel phased array RF coil for spine MR imaging at 7 T JF - Investigative Radiology Y1 - 2009 U6 - http://dx.doi.org/10.1097/RLI.0b013e3181b24ab7 SN - 1536-0210 VL - 44 IS - 11 SP - 734 EP - 740 PB - Lippincott Williams & Wilkins ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - http://dx.doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - CHAP A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - An electromechanical model for cardiac tissue constructs T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER -