TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - Computational comparison of different textile implants to correct apical prolapse in females JF - Current Directions in Biomedical Engineering N2 - Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0159 VL - 4 IS - 1 SP - 661 EP - 664 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Malinowski, Daniel A1 - Fournier, Yvan A1 - Horbach, Andreas A1 - Frick, Michael A1 - Magliani, Mirko A1 - Kalverkamp, Sebastian A1 - Hildinger, Martin A1 - Spillner, Jan A1 - Behbahani, Mehdi A1 - Hima, Flutura T1 - Computational fluid dynamics analysis of endoluminal aortic perfusion JF - Perfusion N2 - Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions. Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch. Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume. Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation. KW - computational fluid dynamics analysis KW - simulation KW - endoluminal KW - aortic perfusion KW - extracorporeal membrane oxygenation Y1 - 2022 U6 - http://dx.doi.org/10.1177/02676591221099809 SN - 1477-111X VL - 0 IS - 0 SP - 1 EP - 8 PB - Sage CY - London ER - TY - JOUR A1 - Alexopoulos, Spiros A1 - Breitbach, Gerd A1 - Hoffschmidt, Bernhard A1 - Stobbe, P. T1 - Computational fluid flow of porous resic ceramic filtering modules and optimization of the channel edge form geometry JF - Proceedings : April 14 - 18, 2008, Leipzig, Germany / hosted by VDI, Society for Chemical and Process Engineering . Vol 2 Y1 - 2008 N1 - Verein Deutscher Ingenieure ; World Filtration Congress ; (10 : ; 2008.04.14-18 : ; Leipzig) ; WFC ; (10 : ; 2008.04.14-18 : ; Leipzig) SP - 300 EP - 304 PB - Filtech Exhibitions CY - Meerbusch ER - TY - JOUR A1 - Frotscher, Ralf A1 - Koch, Jan-Peter A1 - Staat, Manfred T1 - Computational investigation of drug action on human-induced stem cell derived cardiomyocytes JF - Journal of biomechanical engineering Y1 - 2015 U6 - http://dx.doi.org/10.1115/1.4030173 SN - 1528-8951 (E-Journal); 0148-0731 (Print) VL - Vol. 137 IS - iss. 7 SP - 071002-1 EP - 071002-7 PB - ASME CY - New York ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Handrick, K. A1 - Neuhausen, U. T1 - Computational Magnetochemistry: Complementary Quantum Mechanical Tools / Eifert, T. ; Handrick, K. ; Hüning, F. ; Neuhausen, U. ; Schilder, H. ; Lueken, H. JF - Zeitschrift für Anorganische und Allgemeine Chemie (ZAAC) - Journal of Inorganic and General Chemistry . 632 (2006), H. 4 Y1 - 2006 SN - 1521-3749 SP - 521 EP - 529 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Handrick, K. A1 - Neuhausen, U. T1 - Computational Magnetochemistry: Complementary Quantum Mechanical Tools / Eifert, T. ; Handrick, K. ; Hüning, F. ; Neuhausen, U. ; Schilder, H. ; Lueken, H. JF - 20 Jahre Wilhelm-Klemm-Stiftung / Kuratorium der Wilhelm-Klemm-Stiftung (Hrsg.) Y1 - 2006 SN - 978-3-8322-5520-6 SP - 193ff PB - Shaker CY - Aachen ER - TY - CHAP A1 - Reimer, Lars A1 - Wellmer, Georg A1 - Braun, Carsten A1 - Ballmann, Josef T1 - Computational methods for aero-structural analysis and optimisation of aircrafts based on reduced-order structural models T2 - MEGADESIGN and MegaOpt - German initiatives for aerodynamic simulation and optimization in aircraft design. Results of the closing symposium of the MEGADESIGN and MegaOpt projects, Braunschweig, Germany, 23 - 24 May, 2007 / Norbert Kroll ... (Eds.) Notes on numerical fluid mechanics and multidisciplinary design. Vol. 107 N2 - In this part of the MEGADESIGN project, aeroelastic effects are introduced into the aerodynamic analysis of aircrafts by coupling DLR’s flow solvers TAU and FLOWer to a Timoshenko-beam solver. The emerging aeroelastic solvers and a method for the automatic identification of Timoshenko-beam models for wing-box structures were integrated into a simulation environment enabling the combined optimisation of aerodynamic wing shape and structure. Y1 - 2009 SN - 978-3-642-04092-4 SP - 135 EP - 150 PB - Springer CY - Berlin ER - TY - JOUR A1 - Holler, S. A1 - Butenweg, Christoph A1 - Noh, S.-Y. A1 - Meskouris, Konstantin T1 - Computational model of textile-reinforced concrete structures JF - Computers & structures : an international journal Y1 - 2004 U6 - http://dx.doi.org/10.1016/j.compstruc.2004.03.076 SN - 1879-2243 (E-Journal); 0045-7949 (Print) VL - Volume 82 IS - Issues 23-26 SP - 1971 EP - 1979 ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Computational Nanoscience: Do it yourself! : winter school, 14 - 22 February 2006, Forschungszentrum Jülich, Germany ; lecture notes / Grotendorst, Johannes Y1 - 2006 SN - 3-00-017350-1 N1 - NIC series ; 31 ; Forschungszentrum / John-von-Neumann-Institut für Computing PB - NIC CY - Jülich ER - TY - CHAP A1 - Reimer, Lars A1 - Braun, Carsten A1 - Ballmann, Josef T1 - Computational study of the aeroelastic equilibrium configuration of a swept wind tunnel wing model in subsonic flow T2 - High performance computing in science and engineering '06. Transactions of the High Performance Computing Center Stuttgart (HLRS) 2006 / Wolfgang E. Nagel ... Eds. N2 - In the Collaborative Research Center SFB 401 at RWTH Aachen University, the numerical aeroelastic method SOFIA for direct numerical aeroelastic simulation is being progressively developed. Numerical results obtained by applying SOFIA were compared with measured data of static and dynamic aeroelastic wind tunnel tests for an elastic swept wing in subsonic flow. Y1 - 2007 SN - 978-3-540-36165-7 SP - 421 EP - 434 PB - Springer CY - Berlin [u.a.] ER -