TY - GEN A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Corrigendum to “Wind and fairness in ski jumping: A computer modelling analysis” [J. Biomech. 75 (2018) 147–153] T2 - Journal of Biomechanics Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.jbiomech.2021.110690 SN - 0021-9290 N1 - Refers to: Alexander Jung, Wolfram Müller, Manfred Staat: Wind and fairness in ski jumping: A computer modelling analysis. Journal of Biomechanics, Volume 75. 25 June 2018. Pages 147-153. https://doi.org/10.1016/j.jbiomech.2018.05.001 VL - 128 IS - Article number: 110690 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER - TY - GEN A1 - Staat, Manfred A1 - Barry, Steve T1 - Continuum Mechanics with an Introduction to the Finite Element Method / Steve Barry; Manfred Staat. With extensions by Manfred Staat. N2 - Contents: 1 Introduction 2 One Dimensional Continuum Mechanics 3 Tensors 4 Three Dimensional Stress and Strain 5 Conservation Laws 6 Contiunuum Modelling 7 Plain Problems 8 Questions 9 Reference Information KW - Technische Mechanik KW - Finite-Elemente-Methode Y1 - 2006 ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred ED - Erni, Daniel T1 - Computing olympic gold: Ski jumping as an example T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen Y1 - 2016 SN - 978-3-940402-06-6 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 54 EP - 55 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Frotscher, Ralf A1 - Koch, Jan-Peter A1 - Staat, Manfred T1 - Computational investigation of drug action on human-induced stem cell derived cardiomyocytes JF - Journal of biomechanical engineering Y1 - 2015 U6 - http://dx.doi.org/10.1115/1.4030173 SN - 1528-8951 (E-Journal); 0148-0731 (Print) VL - Vol. 137 IS - iss. 7 SP - 071002-1 EP - 071002-7 PB - ASME CY - New York ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - Computational comparison of different textile implants to correct apical prolapse in females JF - Current Directions in Biomedical Engineering N2 - Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0159 VL - 4 IS - 1 SP - 661 EP - 664 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Computational Analysis of Pelvic Floor Dysfunction T2 - Women's Health and Biomechanics N2 - Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence. KW - Pelvic muscle KW - Muscle fibers KW - Passive stretching KW - Pelvic floor dysfunction Y1 - 2018 SN - 978-3-319-71574-2 U6 - http://dx.doi.org/10.1007/978-3-319-71574-2_17 N1 - Lecture Notes in Computational Vision and Biomechanics, vol 29 SP - 217 EP - 230 PB - Springer CY - Cham ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Computation of impacts on elastic solids by methods of bicharacteristics JF - Computational Mechanics '88 : theory and applications ; proceedings of the International Conference on Computational Engineering Science April 10-14, 1988, Atlanta, GA, USA ; vol. 2 N2 - Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists. KW - Bicharakteristikenverfahren KW - Elastizität KW - elastic solids KW - bicharacteristics Y1 - 1988 SP - 1719 EP - 1722 ER - TY - JOUR A1 - Schieren, Mark A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Wappler, Frank A1 - Defosse, Jerome T1 - Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study JF - Anaesthesia Y1 - 2019 SN - 1365-2044 U6 - http://dx.doi.org/10.1111/anae.14815 N1 - Die Anhänge "Table S1 (Impact of sex and level of training on dental force. Results presented as median (IQR [range]) and n (%))" und "Appendix S1 (Measurement technique.)" stehen unter "Supporting Information" zum Download bereit. VL - 74 IS - 12 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Knox, Ronald A1 - Bruggemann, Andrea A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - Combining physiological relevance and throughput for in vitro cardiac contractility measurement JF - Biophysical Journal N2 - Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.bpj.2019.11.3104 SN - 0006-3495 N1 - Raman, Arayind Hariharan im Artikel unter dem Namen: Raman, Alexander H. VL - 118 IS - Issue 3, Supplement 1 SP - 570a PB - Elsevier CY - Amsterdam ER -