TY - JOUR A1 - Olbertz, Klaus A1 - Groth, Alexandra T1 - Die Reform des Mutterschutzrechts - Überblick über die wesentlichen Änderungen JF - NWB - Steuer- und Wirtschaftsrecht Y1 - 2018 SN - 1860-9449 IS - 25 SP - 1883 EP - 1891 PB - NWB Verlag GmbH & Co. KG CY - Herne ER - TY - JOUR A1 - Butenweg, Christoph T1 - Die neue Erdbebenfibel. Neue Hilfsmittel für die Leichtbetonindustrie JF - Tagungsband 61. Ulmer Beton Tage 2017 Y1 - 2017 ER - TY - JOUR A1 - Pfaff, Raphael A1 - Enning, Manfred T1 - Die nachhaltige Alternative zum autonomen Lastwagen JF - Deine Bahn Y1 - 2017 IS - 10 SP - 22 EP - 26 ER - TY - JOUR A1 - Röhlen, Desiree A1 - Pilas, Johanna A1 - Schöning, Michael Josef A1 - Selmer, Thorsten T1 - Development of an amperometric biosensor platform for the combined determination of l-Malic, Fumaric, and l-Aspartic acid JF - Applied Biochemistry and Biotechnology N2 - Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM−1 (L-malate biosensor) and 0.4 μA mM−1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0–10.0 mM with a sensitivity of 0.09 μA mM−1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates. Y1 - 2017 U6 - http://dx.doi.org/10.1007/s12010-017-2578-1 SN - 1559-0291 VL - 183 SP - 566 EP - 581 PB - Springer CY - Berlin ER - TY - JOUR A1 - Funke, Harald A1 - Keinz, Jan A1 - Kusterer, K. A1 - Haj Ayed, A. A1 - Kazari, M. A1 - Kitajima, J. A1 - Horikawa, A. A1 - Okada, K. T1 - Development and Testing of a Low NOX Micromix Combustion Chamber for an Industrial Gas Turbine JF - International Journal of Gas Turbine, Propulsion and Power Systems N2 - The Micromix combustion principle, based on cross-flow mixing of air and hydrogen, promises low emission applications in future gas turbines. The Micromix combustion takes place in several hundreds of miniaturized diffusion-type micro-flames. The major advantage is the inherent safety against flash-back and low NOx-emissions due to a very short residence time of reactants in the flame region. The paper gives insight into the Micromix design and scaling procedure for different energy densities and the interaction of scaling laws and key design drivers in gas turbine integration. Numerical studies, experimental testing, gas turbine integration and interface considerations are evaluated. The aerodynamic stabilization of the miniaturized flamelets and the resulting flow field, flame structure and NOx formation are analysed experimentally and numerically. The results show and confirm the successful adaption of the low NOx Micromix characteristics for a range of different nozzle sizes, energy densities and thermal power output. Y1 - 2017 U6 - http://dx.doi.org/10.38036/jgpp.9.1_27 SN - 1882-5079 VL - 9 IS - 1 SP - 27 EP - 36 ER - TY - JOUR A1 - Sousa, Marcos A. M. A1 - Siqueira, Jose R. Jr. A1 - Vercik, Andres A1 - Schöning, Michael Josef A1 - Oliveira, Osvaldo N. Jr. T1 - Determining the optimized layer-by-layer film architecture with dendrimer/carbon nanotubes for field-effect sensors JF - IEEE Sensors Journal N2 - The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors. Y1 - 2017 U6 - http://dx.doi.org/10.1109/JSEN.2017.2653238 SN - 1558-1748 VL - 17 IS - 6 SP - 1735 EP - 1740 PB - IEEE CY - New York ER - TY - JOUR A1 - Golland, Alexander A1 - Kriegesmann, Torben ED - Härting, Niko T1 - Der Schutz virtueller Identitäten durch die DSGVO JF - PinG Privacy in Germany N2 - Die Frage des Schutzes von virtuellen Identitäten ist – insbesondere bei Online-Medien – von elementarer Bedeutung: Ihre Beantwortung entscheidet über die Anwendbarkeit des Datenschutzrechts auf vermeintlich anonyme Nutzerprofile im Internet. Eine differenzierte Auseinandersetzung mit der Problematik, ob und unter welchen Umständen virtuelle Identitäten dem Datenschutzrecht unterfallen, fehlt bislang. Der vorliegende Beitrag gibt einen Überblick über den Schutz virtueller Identitäten und zeigt Ansätze auf, mittels derer bestimmt werden kann, wann virtuelle Identitäten nach Inkrafttreten der DSGVO durch das Datenschutzrecht geschützt werden. Y1 - 2017 SN - 2197-1862 U6 - http://dx.doi.org/10.37307/j.2196-9817.2017.02.03 VL - 5 IS - 2 SP - 45 EP - 50 PB - Erich Schmidt Verlag CY - Berlin ER - TY - JOUR A1 - Balzer, Hermann A1 - Streit, Daniel T1 - Das Translationsrisiko multinationaler Konzerne in Deutschland: Eine explorative Analyse von Verständnis, Bedeutung und Management-Praxis mit Hilfe der Critical Incident Technique JF - Schmalenbachs Zeitschrift für betriebswirtschaftliche Forschung Y1 - 2017 U6 - http://dx.doi.org/10.1007/s41471-017-0029-x SN - 2366-6153 N1 - Arbeitskreis Finanzierung der Schmalenbach-Gesellschaft e.V. IS - Online first SP - 1 EP - 40 PB - Springer CY - Berlin ER - TY - JOUR A1 - Molinnus, Denise A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips JF - Electroanalysis N2 - The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor. Y1 - 2017 U6 - http://dx.doi.org/10.1002/elan.201700208 SN - 1521-4109 VL - 29 IS - 8 SP - 1840 EP - 1849 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER -