TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 SP - 1 EP - 3 ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kowalczyk, Wojciech A1 - Tran, Thanh Ngoc T1 - Virgin passive colon biomechanics and a literature review of active contraction constitutive models JF - Biomechanics N2 - The objective of this paper is to present our findings on the biomechanical aspects of the virgin passive anisotropic hyperelasticity of the porcine colon based on equibiaxial tensile experiments. Firstly, the characterization of the intestine tissues is discussed for a nearly incompressible hyperelastic fiber-reinforced Holzapfel–Gasser–Ogden constitutive model in virgin passive loading conditions. The stability of the evaluated material parameters is checked for the polyconvexity of the adopted strain energy function using positive eigenvalue constraints of the Hessian matrix with MATLAB. The constitutive material description of the intestine with two collagen fibers in the submucosal and muscular layer each has been implemented in the FORTRAN platform of the commercial finite element software LS-DYNA, and two equibiaxial tensile simulations are presented to validate the results with the optical strain images obtained from the experiments. Furthermore, this paper also reviews the existing models of the active smooth muscle cells, but these models have not been computationally studied here. The review part shows that the constitutive models originally developed for the active contraction of skeletal muscle based on Hill’s three-element model, Murphy’s four-state cross-bridge chemical kinetic model and Huxley’s sliding-filament hypothesis, which are mainly used for arteries, are appropriate for numerical contraction numerical analysis of the large intestine. KW - virgin passive KW - strain energy function KW - smooth muscle contraction KW - viscoelasticity KW - damage Y1 - 2022 U6 - https://doi.org/10.3390/biomechanics2020013 SN - 2673-7078 VL - 2 IS - 2 SP - 138 EP - 157 PB - MDPI CY - Basel ER - TY - JOUR A1 - Mathiak, Gerhard A1 - Willnecker, Rainer A1 - Plescher, Engelbert T1 - Vibrational effects on diffusion experiments JF - Microgravity science and technology : international journal for microgravity research and applications Y1 - 2005 SN - 0938-0108 VL - Vol. 15 IS - No. 1 SP - 295 EP - 300 ER - TY - JOUR A1 - Theysohn, Jens M. A1 - Kraff, Oliver A1 - Eilers, Kristina A1 - Andrade, Dorian A1 - Gerwig, Marcus A1 - Timmann, Dagmar A1 - Schmitt, Franz A1 - Ladd, Mark E. A1 - Ladd, Susanne C. A1 - Bitz, Andreas T1 - Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers JF - PLoS one N2 - Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role. Y1 - 2014 U6 - https://doi.org/10.1371/journal.pone.0092104 SN - 1932-6203 VL - 9 IS - 3 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Hoskens, R. C. P. A1 - Tolstikhin, V.I. A1 - Förster, Arnold A1 - Roer, T.G. van de T1 - Vertically integrated transistor-laser structure, take 2 JF - WOCSDICE 2000, 24th Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe : May 29 - June 02, 2000, Aegean Sea, Greece. Y1 - 2000 SN - 0970311109 N1 - WOCSDICE ; (24, 2000) Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe ; (24 : ; 2000.05.29-06.02) PB - Univ. of Michigan CY - Ann Arbor, Mich. ER - TY - JOUR A1 - Vogt, C. A1 - Mottaghy, Darius A1 - Rath, V. A1 - Marquart, G. A1 - Dijkshoorn, L. A1 - Wolf, A. A1 - Clauser, C. T1 - Vertical variation in heat flow on the Kola Peninsula: palaeoclimate or fluid flow? JF - Geophysical Journal International N2 - Following earlier studies, we present forward and inverse simulations of heat and fluid transport of the upper crust using a local 3-D model of the Kola area. We provide best estimates for palaeotemperatures and permeabilities, their errors and their dependencies. Our results allow discriminating between the two mentioned processes to a certain extent, partly resolving the non-uniqueness of the problem. We find clear indications for a significant contribution of advective heat transport, which, in turn, imply only slightly lower ground surface temperatures during the last glacial maximum relative to the present value. These findings are consistent with the general background knowledge of (i) the fracture zones and the corresponding fluid movements in the bedrock and (ii) the glacial history of the Kola area. Y1 - 2014 U6 - https://doi.org/10.1093/gji/ggu282 SN - 1365-246X VL - 199 IS - 2 SP - 829 EP - 843 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Förster, Arnold A1 - Malzer, S. A1 - Heber, J. A1 - Peter, M. T1 - Vertical transport and relaxation mechanisms in d-doping superlattices. Malzer, S.; Heber, J.; Peter, M.; Eckl, S.; Elpelt, R.; Doehler, G. H.; Förster, A.; Lüth, H. JF - Physica E: Low-dimensional Systems and Nanostructures. 2 (1998), H. 1-4 Y1 - 1998 SN - 1386-9477 SP - 349 EP - 352 ER - TY - JOUR A1 - Heuermann, Holger T1 - Verringerung des Phasenrauschens von Oszillatoren durch Dual-Mode-Resonatoren JF - HF-Report. 20 (2006), H. 5-6 Y1 - 2006 SN - 1431-827X SP - 43 EP - 48 ER - TY - JOUR A1 - Heierli, Joachim A1 - Purves, Ross S. A1 - Felber, Andreas A1 - Kowalski, Julia T1 - Verification of nearest-neighbours interpretations in avalanche forecasting JF - Annals of Glaciology N2 - This paper examines the positive and negative aspects of a range of interpretations of nearest-neighbours models. Measures-oriented and distributionoriented verification methods are applied to categorial, probabilistic and descriptive interpretations of nearest neighbours used operationally in avalanche forecasting in Scotland and Switzerland. The dependence of skill and accuracy measures on base rate is illustrated. The purpose of the forecast and the definition of events are important variables in determining the quality of the forecast. A discussion of the application of different interpretations in operational avalanche forecasting is presented. KW - avalanche Y1 - 2004 SN - 1727-5644 VL - 38 IS - 1 SP - 84 EP - 88 ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. A1 - Muggli, J. A1 - Scheidweiler, A. T1 - Verification of Ionization Chamber Theory JF - Fire Technology. 19 (1983), H. 1 Y1 - 1983 SN - 1572-8099 SP - 14 EP - 21 ER -