TY - JOUR A1 - Schossig, Peter A1 - Dötsch, Christian A1 - Drück, Harald A1 - Göttsche, Joachim A1 - Huenges, Ernst A1 - Kabus, Frank A1 - Tamme, Rainer T1 - Wärmespeicher für die Hausenergieversorgung JF - Wärme und Kälte - Energie aus Sonne und Erde : Jahrestagung des Forschungsverbunds Sonnenenergie in Kooperation mit der Landesinitiative Zukunftsenergie NRW / Stadermann, Gerd, Hrsg. Y1 - 2005 UR - http://publica.fraunhofer.de/documents/N-54108.html SP - 120 EP - 125 PB - Forschungsverbund Sonnenenergie CY - Berlin ER - TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Usbeck, S. A1 - Wagner, L. A1 - Wiediger, Jürgen T1 - Wind-PV-Hybridsystem an der FH Aachen/Jülich JF - Energiewirtschaftliche Tagesfragen. Jg. 44 (1994), H. 9 (special) Y1 - 1994 SN - 0720-6240 SP - 34 EP - 40 ER - TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Plettner-Marliani, J. A1 - Lange, C. A1 - Hövelmann, A. A1 - Schumacher, J. T1 - Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies JF - Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998 Y1 - 1998 SN - 1879-0682 (E-Book); 0960-1481 (Print) SP - 325 EP - 331 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Wollscheid, G. A1 - Meliß, Michael T1 - Vermessung, Bewertung und Optimierung von thermischen Solaranlagen für Einfamilienhäuser / G. Wollscheid ; M. Meliß ; K. Schwarzer JF - Sechstes Symposium Thermische Solarenergie : Kloster Banz ; [Termin: 08. - 10. Mai 1996] / OTTI-Technologie-Kolleg. Fachliche Gesamtltg.: Jürgen Schmid] Y1 - 1996 N1 - Symposium Thermische Solarenergie <6, 1996, Kloster Banz> ; Ostbayerisches Technologie-Transfer-Institut SP - 335 EP - 339 PB - OTTI CY - Regensburg ER - TY - JOUR A1 - Meliß, Michael A1 - Bünde, R. T1 - Unkonventionelle Energiequellen - Entwicklungsstudien (4) JF - Brennstoff, Wärme, Kraft : BWK Y1 - 1978 SN - 0006-9612 (Print) ; 1436-4883 (E-Journal) VL - 30 IS - 3 SP - 120 EP - 126 PB - Springer-VDI-Verlag CY - Düsseldorf ER - TY - JOUR A1 - Herrmann, Ulf A1 - Kelly, Bruce A1 - Price, Henry T1 - Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants JF - Energy : the international journal Y1 - 2002 U6 - http://dx.doi.org/10.1016/S0360-5442(03)00193-2 SN - 0360-5442 N1 - SolarPACES 2002, Zürich, Switzerland, 4–6 September 2002 VL - 29 IS - 5-6 (Special Issue SolarPaces) SP - 883 EP - 893 ER - TY - JOUR A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry T1 - Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems JF - Energy : the international journal Y1 - 2004 U6 - http://dx.doi.org/10.1016/S0360-5442(03)00199-3 SN - 0360-5442 N1 - SolarPACES 2002, Zürich, Switzerland, 4–6 September 2002 VL - 29 IS - 5-6 (Special Issue SolarPaces) SP - 947 EP - 959 ER - TY - JOUR A1 - Rau, Christoph A1 - Alexopoulos, Spiros A1 - Breitbach, Gerd A1 - Hoffschmidt, Bernhard A1 - Latzke, Markus A1 - Sattler, Johannes, Christoph T1 - Transient simulation of a solar-hybrid tower power plant with open volumetric receiver at the location Barstow JF - Energy procedia : proceedings of the SolarPACES 2013 International Conference N2 - In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine's flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well as in any intermediate load levels where the solar portion can vary between 0 to 100%. The simulated plant is based on the configuration of a solar-hybrid power tower project, which is in planning for a site in Northern Algeria. The meteorological data for Barstow-Daggett was taken from the software meteonorm. The solar power tower simulation tool has been developed in the simulation environment MATLAB/Simulink and is validated. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.egypro.2014.03.157 SN - 1876-6102 VL - 49 SP - 1481 EP - 1490 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hennecke, Klaus A1 - Schwarzbözl, Peter A1 - Hoffschmidt, Bernhard A1 - Göttsche, Joachim A1 - Koll, G. A1 - Beuter, M. A1 - Hartz, T. T1 - The solar power tower Jülich – a solar thermal power plant for test and demonstration of air receiver JF - Solar energy and human settlement : Elektronische Ressource : proceedings of ISES world congress 2007 ; (Vol. I - Vol. V) / [ISES Solar World Congress. ISES, International Solar Energy Society]. D. Yogi Goswami ; Yuwen Zhao Y1 - 2007 SN - 978-7-302-16146-2 N1 - Solar World Congress <2007, Beijing> ; International Solar Energy Society SP - 1749 EP - 1753 PB - Tsinghua Univ. Press CY - Beijing ER -