TY - JOUR A1 - Theysohn, Jens M. A1 - Kraff, Oliver A1 - Eilers, Kristina A1 - Andrade, Dorian A1 - Gerwig, Marcus A1 - Timmann, Dagmar A1 - Schmitt, Franz A1 - Ladd, Mark E. A1 - Ladd, Susanne C. A1 - Bitz, Andreas T1 - Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers JF - PLoS one N2 - Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role. Y1 - 2014 U6 - http://dx.doi.org/10.1371/journal.pone.0092104 SN - 1932-6203 VL - 9 IS - 3 PB - PLOS CY - San Francisco ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas T1 - Usability for Blended Shopping - Solving Major Flaws by Applying Usability Engineering and Proven Integration Technologies T2 - Proceedings of the 11th International Conference on e-Business, ICE-B 2014, Vienna, Austria Y1 - 2014 SN - 978-989-758-043-7 U6 - http://dx.doi.org/10.5220/0005113502160223 SP - 216 EP - 223 ER - TY - CHAP A1 - Neumann, Tobias A1 - Ferrein, Alexander A1 - Kallweit, Stephan A1 - Scholl, Ingrid T1 - Towards a mobile mapping robot for underground mines T2 - 7th Conference of Robotics and Mechatronics : RobMech 2014 : 27th and 28th Nov. 2014, Cape Town Y1 - 2014 SP - 1 EP - 6 ER - TY - BOOK A1 - Hüning, Felix T1 - The fundamentals of electrical engineering for mechatronics Y1 - 2014 SN - 978-3-11-034991-7 (Druckausg.) SN - 978-3-11-030840-2 (E-Book) PB - de Gruyter CY - Berlin ER - TY - CHAP A1 - Niemüller, Tim A1 - Ewert, Daniel A1 - Reuter, Sebastian A1 - Ferrein, Alexander A1 - Jeschke, Sabina A1 - Lakemeyer, Gerhard T1 - RoboCup logistics league sponsored by festo: A competitive factory automation testbed T2 - RoboCup 2013: Robot World Cup XVII : Eindhoven; Netherlands; 1 July 2013 through 1 July 2013. (Lecture notes in computer science ; 8371) N2 - A new trend in automation is to deploy so-called cyber-physical systems (CPS) which combine computation with physical processes. The novel RoboCup Logistics League Sponsored by Festo (LLSF) aims at such CPS logistic scenarios in an automation setting. A team of robots has to produce products from a number of semi-finished products which they have to machine during the game. Different production plans are possible and the robots need to recycle scrap byproducts. This way, the LLSF is a very interesting league offering a number of challenging research questions for planning, coordination, or communication in an application-driven scenario. In this paper, we outline the objectives of the LLSF and present steps for developing the league further towards a benchmark for logistics scenarios for CPS. As a major milestone we present the new automated referee system which helps in governing the game play as well as keeping track of the scored points in a very complex factory scenario. Y1 - 2014 SN - 978-3-662-44467-2 (Print) 978-3-662-44468-9 (Online) SP - 336 EP - 347 PB - Springer CY - Berlin ER - TY - CHAP A1 - Neugebauer, Georg A1 - Brutschy, Lucas A1 - Meyer, Ulrike A1 - Wetzel, Susanne ED - Garcia-Alfaro, Joaquin ED - Lioudakis, Georgios ED - Cuppens-Boulahia, Nora ED - Foley, Simon ED - Fitzgerald, William M. T1 - Privacy-preserving multi-party reconciliation secure in the malicious model T2 - DPM 2013, SETOP 2013: Data Privacy Management and Autonomous Spontaneous Security N2 - The problem of fair and privacy-preserving ordered set reconciliation arises in a variety of applications like auctions, e-voting, and appointment reconciliation. While several multi-party protocols have been proposed that solve this problem in the semi-honest model, there are no multi-party protocols that are secure in the malicious model so far. In this paper, we close this gap. Our newly proposed protocols are shown to be secure in the malicious model based on a variety of novel non-interactive zero-knowledge-proofs. We describe the implementation of our protocols and evaluate their performance in comparison to protocols solving the problem in the semi-honest case. KW - Privacy-enhancing technologies KW - Secure multi-party computation KW - Cryptographic protocols KW - Zero-knowledge proofs KW - Malicious model Y1 - 2014 SN - 978-3-642-54567-2 (Print) SN - 978-3-642-54568-9 (Online) U6 - http://dx.doi.org/10.1007/978-3-642-54568-9_12 N1 - 8th International Workshop, DPM 2013, and 6th International Workshop, SETOP 2013, Egham, UK, September 12-13, 2013. Part of the Lecture Notes in Computer Science book series (LNSC,volume 8247) SP - 178 EP - 193 PB - Springer CY - Berlin ER - TY - CHAP A1 - Hüning, Felix T1 - Power semiconductors : key components for HEV/EV T2 - FISITA 2014 World Automotive Congress : 2 - 6 June, Maastricht, the Netherlands International Federation of Automotive Engineering Societies Y1 - 2014 N1 - Datenformat: PDF PB - KIVI CY - [s.l.] ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Vos, Eline K. A1 - Maas, Marnix C. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Uden, Mark J. van A1 - Kobus, Thiele A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer JF - Investigative Radiology N2 - Objectives The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T. Materials and Methods In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Results Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Conclusions Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels. Y1 - 2014 U6 - http://dx.doi.org/10.1097/RLI.0000000000000012 SN - 1536-0210 VL - 49 IS - 5 SP - 363 EP - 372 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. ER - TY - JOUR A1 - Beck, Daniel A1 - Buchleitner, Martin A1 - Ferrein, Alexander A1 - Niemüller, Tim A1 - Steinbauer, Gerald T1 - Mostly Harmless & AllemaniACs - mixed innovations Y1 - 2014 SP - 1 EP - 8 ER - TY - CHAP A1 - Heuermann, Holger A1 - Finger, Torsten ED - Günther, Michael T1 - Microwave Spark Plug for Very High-Pressure Conditions T2 - Ignition systems for gasoline engines Y1 - 2014 SP - 269 EP - 282 PB - DCM Druck CY - Meckenheim ER -