TY - CHAP A1 - Kroll-Ludwigs, Kathrin T1 - Small Claims Regulation T2 - European Encyclopedia of Private International Law Y1 - 2017 SN - 9781782547228 PB - Edward Elgar Publishing CY - Cheltenham, UK ER - TY - CHAP A1 - Altherr, Lena A1 - Dörig, Bastian A1 - Ederer, Thorsten A1 - Pelz, Peter Franz A1 - Pfetsch, Marc A1 - Wolf, Jan T1 - A mixed-integer nonlinear program for the design of gearboxes T2 - Operations Research Proceedings 2016 N2 - Gearboxes are mechanical transmission systems that provide speed and torque conversions from a rotating power source. Being a central element of the drive train, they are relevant for the efficiency and durability of motor vehicles. In this work, we present a new approach for gearbox design: Modeling the design problem as a mixed-integer nonlinear program (MINLP) allows us to create gearbox designs from scratch for arbitrary requirements and—given enough time—to compute provably globally optimal designs for a given objective. We show how different degrees of freedom influence the runtime and present an exemplary solution. Y1 - 2017 SN - 978-3-319-55701-4 U6 - https://doi.org/10.1007/978-3-319-55702-1_31 SP - 227 EP - 233 PB - Springer CY - Cham ER - TY - CHAP A1 - Steuer-Dankert, Linda A1 - Bouffier, Anna A1 - Gaedicke, Sonja A1 - Leicht-Scholten, Carmen T1 - Diversifying engineering education: a transdisciplinary approach from RWTH Aachen University T2 - Strategies for increasing diversity in engineering majors and careers N2 - Engineers and therefore engineering education are challenged by the increasing complexity of questions to be answered globally. The education of future engineers therefore has to answer with curriculums that build up relevant skills. This chapter will give an example how to bring engineering and social responsibility successful together to build engineers of tomorrow. Through the integration of gender and diversity perspectives, engineering research and teaching is expanded with new perspectives and contents providing an important potential for innovation. Aiming on the enhancement of engineering education with distinctive competencies beyond technical expertise, the teaching approach introduced in the chapter represents key factors to ensure that coming generations of engineers will be able to meet the requirements and challenges a changing globalized world holds for them. The chapter will describe how this approach successfully has been implemented in the curriculum in engineering of a leading technical university in Germany. Y1 - 2017 SN - 9781522522126 U6 - https://doi.org/10.4018/978-1-5225-2212-6.ch010 SP - 201 EP - 235 PB - IGI Global CY - Hershey, USA ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Nanomaterial-Modified Capacitive Field-Effect Biosensors T2 - Springer Series on Chemical Sensors and Biosensors (Methods and Applications) N2 - The coupling of charged molecules, nanoparticles, and more generally, inorganic/organic nanohybrids with semiconductor field-effect devices based on an electrolyte–insulator–semiconductor (EIS) system represents a very promising strategy for the active tuning of electrochemical properties of these devices and, thus, opening new opportunities for label-free biosensing by the intrinsic charge of molecules. The simplest field-effect sensor is a capacitive EIS sensor, which represents a (bio-)chemically sensitive capacitor. In this chapter, selected examples of recent developments in the field of label-free biosensing using nanomaterial-modified capacitive EIS sensors are summarized. In the first part, we present applications of EIS sensors modified with negatively charged gold nanoparticles for the label-free electrostatic detection of positively charged small proteins and macromolecules, for monitoring the layer-by-layer formation of oppositely charged polyelectrolyte (PE) multilayers as well as for the development of an enzyme-based biomolecular logic gate. In the second part, examples of a label-free detection by means of EIS sensors modified with a positively charged weak PE layer are demonstrated. These include electrical detection of on-chip and in-solution hybridized DNA (deoxyribonucleic acid) as well as an EIS sensor with pH-responsive weak PE/enzyme multilayers for enhanced field-effect biosensing. KW - Biomolecular logic gate KW - DNA KW - Enzyme biosensor KW - Field-effect sensor KW - Gold nanoparticle Y1 - 2017 U6 - https://doi.org/10.1007/5346_2017_2 SP - 1 EP - 25 PB - Springer CY - Berlin, Heidelberg ER - TY - CHAP A1 - Tran, N. T. A1 - Tran, Thanh Ngoc A1 - Matthies, M. G. A1 - Stavroulakis, G. E. A1 - Staat, Manfred T1 - Shakedown Analysis Under Stochastic Uncertainty by Chance Constrained Programming T2 - Advances in Direct Methods for Materials and Structures N2 - In this paper we propose a stochastic programming method to analyse limit and shakedown of structures under uncertainty condition of strength. Based on the duality theory, the shakedown load multiplier formulated by the kinematic theorem is proved actually to be the dual form of the shakedown load multiplier formulated by static theorem. In this investigation a dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit and the shakedown limit. The edge-based smoothed finite element method (ES-FEM) with three-node linear triangular elements is used for structural analysis. Y1 - 2017 SN - 978-3-319-59810-9 U6 - https://doi.org/10.1007/978-3-319-59810-9_6 SP - 85 EP - 103 PB - Springer CY - Cham ER - TY - CHAP A1 - Niemueller, Tim A1 - Zwilling, Frederik A1 - Lakemeyer, Gerhard A1 - Löbach, Matthias A1 - Reuter, Sebastian A1 - Jeschke, Sabina A1 - Ferrein, Alexander T1 - Cyber-Physical System Intelligence T2 - Industrial Internet of Things N2 - Cyber-physical systems are ever more common in manufacturing industries. Increasing their autonomy has been declared an explicit goal, for example, as part of the Industry 4.0 vision. To achieve this system intelligence, principled and software-driven methods are required to analyze sensing data, make goal-directed decisions, and eventually execute and monitor chosen tasks. In this chapter, we present a number of knowledge-based approaches to these problems and case studies with in-depth evaluation results of several different implementations for groups of autonomous mobile robots performing in-house logistics in a smart factory. We focus on knowledge-based systems because besides providing expressive languages and capable reasoning techniques, they also allow for explaining how a particular sequence of actions came about, for example, in the case of a failure. KW - Smart factory KW - Industry 4.0 KW - Multi-robot systems KW - Autonomous mobile robots KW - RoboCup Y1 - 2017 SN - 978-3-319-42559-7 U6 - https://doi.org/10.1007/978-3-319-42559-7_17 N1 - Springer Series in Wireless Technology SP - 447 EP - 472 PB - Springer CY - Cham ER - TY - CHAP A1 - Dachwald, Bernd ED - Knopf, George K. ED - Otani, Yukitoshi T1 - Light propulsion systems for spacecraft T2 - Optical nano and micro actuator technology Y1 - 2017 SN - 9781315217628 (eBook) SP - 577 EP - 598 PB - CRC Press CY - Boca Raton ER - TY - CHAP A1 - Koch, Claudia A1 - Poghossian, Arshak A1 - Wege, Christina A1 - Schöning, Michael Josef ED - Wege, Christina T1 - TMV-Based Adapter Templates for Enhanced Enzyme Loading in Biosensor Applications T2 - Virus-Derived Nanoparticles for Advanced Technologies N2 - Nanotubular tobacco mosaic virus (TMV) particles and RNA-free lower-order coat protein (CP) aggregates have been employed as enzyme carriers in different diagnostic layouts and compared for their influence on biosensor performance. In the following, we describe a label-free electrochemical biosensor for improved glucose detection by use of TMV adapters and the enzyme glucose oxidase (GOD). A specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CP aggregates was achieved via bioaffinity binding. Glucose sensors with adsorptively immobilized [SA]-GOD, and with [SA]-GOD cross-linked with glutardialdehyde, respectively, were tested in parallel on the same sensor chip. Comparison of these sensors revealed that TMV adapters enhanced the amperometric glucose detection remarkably, conveying highest sensitivity, an extended linear detection range and fastest response times. These results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for applications in biosensorics and biochips. Here, we describe the fabrication and use of amperometric sensor chips combining an array of circular Pt electrodes, their loading with GOD-modified TMV nanotubes (and other GOD immobilization methods), and the subsequent investigations of the sensor performance. KW - Tobacco mosaic virus (TMV) KW - Coat protein KW - Enzyme nanocarrier KW - Glucose biosensor KW - Glucose oxidase Y1 - 2018 SN - 978-1-4939-7808-3 U6 - https://doi.org/10.1007/978-1-4939-7808-3 N1 - Methods in Molecular Biology, vol 1776 SP - 553 EP - 568 PB - Humana Press CY - New York, NY ER - TY - CHAP A1 - Artmann, Gerhard A1 - Meruvu, Haritha A1 - Kizildag, Sefa A1 - Temiz Artmann, Aysegül ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Functional Toxicology and Pharmacology Test of Cell Induced Mechanical Tensile Stress in 2D and 3D Tissue Cultures T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - Mechanical forces/tensile stresses are critical determinants of cellular growth, differentiation and migration patterns in health and disease. The innovative “CellDrum technology” was designed for measuring mechanical tensile stress of cultured cell monolayers/thin tissue constructs routinely. These are cultivated on very thin silicone membranes in the so-called CellDrum. The cell layers adhere firmly to the membrane and thus transmit the cell forces generated. A CellDrum consists of a cylinder which is sealed from below with a 4 μm thick, biocompatible, functionalized silicone membrane. The weight of cell culture medium bulbs the membrane out downwards. Membrane indentation is measured. When cells contract due to drug action, membrane, cells and medium are lifted upwards. The induced indentation changes allow for lateral drug induced mechanical tension quantification of the micro-tissues. With hiPS-induced (human) Cardiomyocytes (CM) the CellDrum opens new perspectives of individualized cardiac drug testing. Here, monolayers of self-beating hiPS-CMs were grown in CellDrums. Rhythmic contractions of the hiPS-cells induce membrane up-and-down deflections. The recorded cycles allow for single beat amplitude, single beat duration, integration of the single beat amplitude over the beat time and frequency analysis. Dose effects of agonists and antagonists acting on Ca2+ channels were sensitively and highly reproducibly observed. Data were consistent with published reference data as far as they were available. The combination of the CellDrum technology with hiPS-Cardiomyocytes offers a fast, facile and precise system for pharmacological and toxicological studies. It allows new preclinical basic as well as applied research in pharmacolgy and toxicology. Y1 - 2018 SN - 978-981-10-7904-7 U6 - https://doi.org/10.1007/978-981-10-7904-7_7 SP - 157 EP - 192 PB - Springer CY - Singapore ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Seifarth, Volker A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Staat, Manfred ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Growth Modelling Promoting Mechanical Stimulation of Smooth Muscle Cells of Porcine Tubular Organs in a Fibrin-PVDF Scaffold T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - Reconstructive surgery and tissue replacements like ureters or bladders reconstruction have been recently studied, taking into account growth and remodelling of cells since living cells are capable of growing, adapting, remodelling or degrading and restoring in order to deform and respond to stimuli. Hence, shapes of ureters or bladders and their microstructure change during growth and these changes strongly depend on external stimuli such as training. We present the mechanical stimulation of smooth muscle cells in a tubular fibrin-PVDFA scaffold and the modelling of the growth of tissue by stimuli. To this end, mechanotransduction was performed with a kyphoplasty balloon catheter that was guided through the lumen of the tubular structure. The bursting pressure was examined to compare the stability of the incubated tissue constructs. The results showed the significant changes on tissues with training by increasing the burst pressure as a characteristic mechanical property and the smooth muscle cells were more oriented with uniformly higher density. Besides, the computational growth models also exhibited the accurate tendencies of growth of the cells under different external stimuli. Such models may lead to design standards for the better layered tissue structure in reconstructing of tubular organs characterized as composite materials such as intestines, ureters and arteries. KW - Mechanical simulation KW - Growth modelling KW - Ureter KW - Bladder KW - Reconstruction Y1 - 2018 SN - 978-981-10-7904-7 U6 - https://doi.org/10.1007/978-981-10-7904-7_9 SP - 209 EP - 232 PB - Springer CY - Singapore ER -