TY - CHAP A1 - Hüning, Felix T1 - Power Semiconductors for the automotive 48V board net T2 - PCIM Europe 2016 Conference Proceedings Y1 - 2016 SN - 978-3-8007-4186-1 SP - 1963 EP - 1969 PB - VDE Verl. CY - Berlin ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Erni, Daniel T1 - Female pelvic floor dysfunction: progress weakening of the support system T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen N2 - The structure of the female pelvic floor (PF) is an inter-related system of bony pelvis,muscles, pelvic organs, fascias, ligaments, and nerves with multiple functions. Mechanically, thepelvic organ support system are of two types: (I) supporting system of the levator ani (LA) muscle,and (II) the suspension system of the endopelvic fascia condensation [1], [2]. Significantdenervation injury to the pelvic musculature, depolimerization of the collagen fibrils of the softvaginal hammock, cervical ring and ligaments during pregnancy and vaginal delivery weakens thenormal functions of the pelvic floor. Pelvic organ prolapse, incontinence, sexual dysfunction aresome of the dysfunctions which increases progressively with age and menopause due toweakened support system according to the Integral theory [3]. An improved 3D finite elementmodel of the female pelvic floor as shown in Fig. 1 is constructed that: (I) considers the realisticsupport of the organs to the pelvic side walls, (II) employs the improvement of our previous FEmodel [4], [5] along with the patient based geometries, (III) incorporates the realistic anatomy andboundary conditions of the endopelvic (pubocervical and rectovaginal) fascia, and (IV) considersvarying stiffness of the endopelvic fascia in the craniocaudal direction [3]. Several computationsare carried out on the presented computational model with healthy and damaged supportingtissues, and comparisons are made to understand the physiopathology of the female PF disorders. Y1 - 2016 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 11 EP - 12 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred ED - Erni, Daniel T1 - Computing olympic gold: Ski jumping as an example T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen Y1 - 2016 SN - 978-3-940402-06-6 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 54 EP - 55 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Kahmann, Stephanie A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Müller, Lars-Peter A1 - Staat, Manfred ED - Erni, Daniel T1 - Impact of a proximal radial shortening osteotomy on the distribution of forces and the stability of the elbow T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen N2 - The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly. Y1 - 2016 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Kasper, Katharina A1 - Schiffels, Johannes A1 - Krafft, Simone A1 - Kuperjans, Isabel A1 - Elbers, Gereon A1 - Selmer, Thorsten T1 - Biogas Production on Demand Regulated by Butyric Acid Addition T2 - IOP Conference Series: Earth and Environmental Science. Bd. 32 Y1 - 2016 U6 - http://dx.doi.org/10.1088/1755-1315/32/1/012009 SN - 1755-1315 N1 - ICARET 2016, International Conference on Advances in Renewable Energy and Technologies, Putrajaya, MY, Feb 23-25, 2016 VL - 32 SP - 012009/1 EP - 012009/4 ER - TY - CHAP A1 - Laack, Walter van T1 - Schnittstelle Tod: Wo stehen wir nach 40 Jahren NTE-Forschung? Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:101:1-201603132912 SN - 978-3-936624-30-4 (Print-Ausgabe) SN - 978-3-936624-32-8 (Online-Ausgabe) N1 - Tagungsbeiträge des 4. Europäischen Seminars am 07. November 2015 in Aachen zum Thema Nahtoderfahrungen mit dem Serientitel: "Schnittstelle Tod" PB - van Laack GmbH CY - Aachen ER - TY - CHAP A1 - Becker, Sebastian A1 - Höfken, Hans-Wilhelm A1 - Schütz, Philip A1 - Schuba, Marko ED - Schartner, P. T1 - IT-forensische Erkennung modifizierter Android-Apps T2 - Proceedings of DACH Security 2016, Klagenfurt, Austria, September 2016 N2 - Malware auf Smartphones ist ein Problem, dem auch Strafverfolgungsbehörden immer häufiger gegenüberstehen. Insbesondere Telefone, bei denen potentiell schadhafte Apps zu einem finanziellen Schaden geführt haben, finden sich auf den Schreibtischen der Polizei wieder. Dabei müssen die Ermittler möglichst schnell und gezielt erkennen können, ob eine App tatsächlich schadhaft manipuliert wurde, was manipuliert wurde und mit wem die App kommuniziert. Klassische Malware-Erkennungsverfahren helfen zwar bei der generellen Erkennung schadhafter Software, sind aber für die polizeiliche Praxis nicht geeignet. Dieses Paper stellt ein Programm vor, welches gerade die forensischen Fragestellungen berücksichtigt und so für den Einsatz in der Strafverfolgung in Frage kommt. Y1 - 2016 SP - 120 EP - 125 ER - TY - CHAP A1 - Bonney, Gregor A1 - Nagel, Stefan A1 - Schuba, Marko ED - Schartner, P. T1 - Risiko Smart Home – Angriff auf ein Babymonitorsystem T2 - Proceedings of DACH Security 2016, Klagenfurt, Austria, September 2016 N2 - Unser Zuhause wird zunehmend intelligenter. Smart Homes bieten uns die Steuerung von Haus- oder Unterhaltungstechnik bequem vom Smartphone aus. Junge Familien nutzen die Technologie, um mittels vernetzten Babymonitorsystemen ihren Nachwuchs von überall aus im Blick zu haben. Davon auszugehen, dass solche Systeme mit einem Fokus auf Sicherheit entwickelt wurden, um die sehr persönlichen Daten zu schützen, ist jedoch ein Trugschluss. Die Untersuchung eines handelsüblichen und keineswegs billigen Systems zeigt, dass die Geräte sehr einfach kompromittiert und missbraucht werden können. Y1 - 2016 SP - 371 EP - 378 ER - TY - CHAP A1 - Staat, Manfred A1 - Duong, Minh Tuan T1 - Smoothed Finite Element Methods for Nonlinear Solid Mechanics Problems: 2D and 3D Case Studies T2 - Proceedings of the National Science and Technology Conference on Mechanical - Transportation Engineering (NSCMET 2016), 13th October 2016, Hanoi, Vietnam, Vol.2 N2 - The Smoothed Finite Element Method (SFEM) is presented as an edge-based and a facebased techniques for 2D and 3D boundary value problems, respectively. SFEMs avoid shortcomings of the standard Finite Element Method (FEM) with lower order elements such as overly stiff behavior, poor stress solution, and locking effects. Based on the idea of averaging spatially the standard strain field of the FEM over so-called smoothing domains SFEM calculates the stiffness matrix for the same number of degrees of freedom (DOFs) as those of the FEM. However, the SFEMs significantly improve accuracy and convergence even for distorted meshes and/or nearly incompressible materials. Numerical results of the SFEMs for a cardiac tissue membrane (thin plate inflation) and an artery (tension of 3D tube) show clearly their advantageous properties in improving accuracy particularly for the distorted meshes and avoiding shear locking effects. Y1 - 2016 SP - 440 EP - 445 ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Tran, Thanh Ngoc A1 - Matthies, Hermann G. A1 - Stavroulakis, Georgios Eleftherios A1 - Staat, Manfred T1 - FEM Shakedown of uncertain structures by chance constrained programming T2 - PAMM Proceedings in Applied Mathematics and Mechanics Y1 - 2016 U6 - http://dx.doi.org/10.1002/pamm.201610346 SN - 1617-7061 N1 - Special Issue: Joint 87th Annual Meeting of the International Association of Applied Mathematics and Mechanics (GAMM) and Deutsche Mathematiker-Vereinigung VL - 16 IS - 1 SP - 715 EP - 716 ER -