TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Fend, Thomas A1 - Pitz-Paal, Robert A1 - Reutter, Oliver T1 - Two novel high-porosity materials as volumetric receivers for concentrated solar radiation / Thomas Fend ; Robert Pitz-Paal ; Oliver Reutter ... Bernhard Hoffschmidt JF - Solar energy materials & solar cells. 84 (2004), H. 1 Y1 - 2004 SN - 0927-0248 SP - 291 EP - 304 ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Fend, Thomas A1 - Pitz-Paal, Robert A1 - Reutter, Oliver T1 - Porous materials as open volumetric solar receivers - Experimental determination of thermophysical and heat transfer properties / Thomas Fend ; Bernhard Hoffschmidt ... JF - Energy. 29 (2004), H. 5 Y1 - 2004 SN - 0360-5442 SP - 823 EP - 834 ER - TY - JOUR A1 - Mikulics, M. A1 - Camara, I. A1 - Hardt, A. van der A1 - Fox, A. A1 - Förster, Arnold A1 - Gusten, R. A1 - Lüth, H. A1 - Kordos, P. T1 - Generation of THz radiation by photomixing in low-temperature-grown MBE GaAs JF - Fifth International Conference on Advanced Semiconductor Devices and Microsystems : conference proceedings ; Smolenice Castle, Slovakia, October 17 - 21, 2004 / [organizers: Institute of Electrical Engineering, Slovak Academy of Sciences, Bratislava and Microelectronics Department, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Bratislava]. Ed. by J. Osvald Y1 - 2004 SN - 0-7803-8335-7 N1 - International Conference on Advanced Semiconductor Devices and Microsystems <5, 2004, Smolenice> ; ASDAM <5, 2004, Smolenice> ; IEEE catalog numer: 04EX867 SP - 231 EP - 234 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Zatko, B. A1 - Dubecký, F. A1 - Bohacek, P. A1 - Gombia, E. A1 - Frigeri, P. A1 - Mosca, R. A1 - Franchi, S. A1 - Huarn, J. A1 - Nescas, V. A1 - Sekacova, M. A1 - Förster, Arnold A1 - Kordos, P. T1 - On the spectrometric performance limit of radiation detectors based on semi-insulating GaAs JF - Nuclear instruments and methods in physics research, Section A. 531 (2004), H. 1-2 Y1 - 2004 SN - 0168-9002 SP - 111 EP - 120 ER - TY - JOUR A1 - Srnanek, R. A1 - Geurts, J. A1 - Lentze, M. A1 - Irmer, G. A1 - Donoval, D. A1 - Brdecka, P. A1 - Kordos, P. A1 - Förster, Arnold A1 - Sciana, B. A1 - Radziewicz, D. A1 - Tlaczala, M. T1 - Study of d-doped GaAs layers by micro-Raman spectroscopy on bevelled samples JF - Applied surface science . 230 (2004), H. 1 -4 Y1 - 2004 SN - 0169-4332 N1 - ISSN der E-Ausg.: 0169-4332 SP - 379 EP - 385 ER - TY - CHAP A1 - Surtees, A. J. A1 - Gillespie, A. A1 - Kern, Alexander A1 - Rousseau, A. T1 - DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION N2 - Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabwägung N2 - IEC Technical Committee 81 is currently creating the new IEC 62305 series of standards on Lightning Protection. Working Group 9 is responsible for Part 2 of this series, which deals with the assessment and management of risk its CDV (Committee Draft for Voting) stage and has been circulated to National Committees for comment. The paper details the development of the Simplified IEC Risk Assessment Calculator software tool as described in Informative Annex J of IEC62305-2 Ed.1/CDV 2. This tool is intended as a simplified implementation of the more rigorous treatment of risk management found in the written document. It is designed to be relatively intuitive for users who wish to obtain an initial assessment of risk sensitivity, but should not be considered a substitute to a full understanding of the methods provided in the standard when dealing with more complicated structures or those where greater risks to personal or system operation are involved. KW - Risiko KW - Risikoabwägung KW - Blitzrisiko KW - Blitzschutz KW - Risk KW - Risk Management KW - Risk Assessment KW - Lightning Risk KW - Lightning Protection Y1 - 2004 ER - TY - CHAP A1 - Kern, Alexander A1 - Heidler, Fridolin A1 - Seevers, M. A1 - Zischank, Wolfgang J. T1 - Magnetic Fields and Induced Voltages in case of a Direct Strike - Comparison of Results obtained from Measurements at a Scaled Building to those of IEC 62305-4 N2 - In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield. N2 - Auswirkungen eines direkten Blitzeinschlages auf ein Gebäude, Vergleich von experimentellen Ergebnissen und Berechnungen basierend auf einer Formel aus der IEC 62305-4 KW - Blitz KW - Direkter Blitzschlag KW - Elektromagnetischer Schutzschild KW - Magnetische Felder KW - Induzierte Spannungen KW - Kalkulation KW - Direct lightning strike KW - electromagnetic shield KW - magnetic fields KW - induced voltages KW - calculations Y1 - 2004 SN - 0304-3886 N1 - Journal of electrostatics: Beitr. auf S. 379 - 385. doi:10.1016/j.elstat.2006.09.004 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Stimper, K. A1 - Kern, Alexander A1 - Seevers, M. T1 - Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building N2 - Laborexperimente zu Blitzschutzzonen in Stahlbetongebäuden anhand eines Modells im Maßstab 1:6 N2 - For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied. KW - Blitzschlag KW - Elektromagnetischer Schutzschild KW - Stahlbeton KW - Maßstabsgetreues Modell KW - Lightning KW - electromagnetic shielding KW - reinforced concrete KW - scaled model Y1 - 2004 ER - TY - JOUR A1 - Chudoba, Rostislav A1 - Butenweg, Christoph A1 - Peiffer, F. T1 - Technical information system for collaborative material research JF - Advances in engineering software Y1 - 2004 U6 - http://dx.doi.org/10.1016/j.advengsoft.2004.03.021 SN - 1873-5339 (E-Journal); 0965-9978 (Print) VL - Volume 35 IS - Issue 10-11 SP - 747 EP - 756 ER - TY - JOUR A1 - Holler, S. A1 - Butenweg, Christoph A1 - Noh, S.-Y. A1 - Meskouris, Konstantin T1 - Computational model of textile-reinforced concrete structures JF - Computers & structures : an international journal Y1 - 2004 U6 - http://dx.doi.org/10.1016/j.compstruc.2004.03.076 SN - 1879-2243 (E-Journal); 0045-7949 (Print) VL - Volume 82 IS - Issues 23-26 SP - 1971 EP - 1979 ER -