TY - CHAP A1 - Aringhoff, R. A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Kistner, Rainer A1 - Nava, P. A1 - Osuna, R. ED - Steinfeld, Aldo T1 - AndaSol : 50MW Solar Plants with 9 Hour Storage for Southern Spain T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 37 EP - 42 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Herrmann, Ulf A1 - Kelly, Bruce A1 - Price, Henry ED - Steinfeld, Aldo T1 - Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 517 EP - 524 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Grothof, M. A1 - Schwarte, Rudolf A1 - Buxbaum, Bernd A1 - Ringbeck, Thorsten ED - Wagner, Elmar T1 - Product monitoring with MSM-PMD-Array T2 - Proceedings / OPTO 2002 : an event of the Association for Sensor Technology AMA ; 14 - 16 May 2002, Exhibition Centre Erfurt, Germany / International Conference Optoelectronics, Optical Sensors & Measuring Techniques Y1 - 2002 N1 - OPTO <5, 2002, Erfurt> ; International Conference Optoelectronics, Optical Sensors & Measuring Techniques SP - 41 EP - 47 PB - AMA Service GmbH CY - Wunsdorf ER - TY - CHAP A1 - Blake, D. A1 - Moens, L. A1 - Hale, M.-J. A1 - Price, Henry A1 - Keaney, David W. A1 - Herrmann, Ulf ED - Steinfeld, Aldo T1 - New heat transfer and storage fluids for parabolic trough solar thermal electric plants T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 63 EP - 66 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry ED - Steinfeld, Aldo T1 - Trough integration into power plants : a study on the performance and economy of integrated solar combined cycle systems T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 661 EP - 671 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry ED - Pearson, J. Boise T1 - Solar Trough Integration Into Combined Cycle Systems T2 - Solar engineering 2002 : proceedings of the International Solar Energy Conference ; presented at the 2002 International Solar Energy Conference, a part of Solar 2002 - Sunrise on the Reliable Energy Economy, June 15 - 20, 2002, Reno, Nevada Y1 - 2002 SN - 0-7918-1689-3 U6 - https://doi.org/doi:10.1115/SED2002-1072 SP - 351 EP - 359 PB - ASME ER - TY - CHAP A1 - Zang, Zhigang A1 - Hess, Holger A1 - Ringbeck, Thorsten A1 - Schwarte, Rudolf ED - Kamerman, Gary W. T1 - Phase-lock techniques using new correlation receivers for TOF-laser ranging T2 - Laser radar technology and applications VII : 3 - 4 April 2002, Orlando, USA. - (SPIE proceedings series ; 4723) Y1 - 2002 SN - 0-8194-4473-1 U6 - https://doi.org/10.1117/12.476402 SN - 0038-7355 SN - 0361-0748 SN - 0277-786X N1 - Laser Radar Technology and Applications <7, 2002, Orlando, FL> SP - 112 EP - 120 PB - SPIE, International Society for Optical Engineering CY - Bellingham, Wash. ER - TY - CHAP A1 - Buxbaum, Bernd A1 - Schwarte, Rudolf A1 - Ringbeck, Thorsten A1 - Grothof, Markus A1 - Luan, Xuming ED - Schreiber, Ulrich T1 - MSM-PMD as correlation receiver in a new 3D-ranging system T2 - Laser radar ranging and atmospheric lidar techniques III : 17 - 18 September 2001, Toulouse, France. - (SPIE proceedings series ; 4546) Y1 - 2002 SN - 0-8194-4271-2 U6 - https://doi.org/10.1117/12.453994 SN - 0038-7355 SN - 0361-0748 SN - 0277-786X N1 - Laser Radar: Ranging and Atmospheric Lidar Techniques <3, 2001, Toulouse> SP - 145 EP - 154 PB - SPIE CY - Bellingham, Wash. ER - TY - CHAP A1 - Dielmann, Klaus-Peter T1 - Umsetzung Strom-/Gasmarkt nach der Liberalisierung N2 - Neues Energierecht Strom Neues Energierecht Gas Emissionshandel in Europa - ein interessanter Markt? KW - Energierecht KW - Elektrizität KW - Gas KW - Emissionshandel Y1 - 2001 ER - TY - CHAP A1 - Kern, Alexander A1 - Meppelink, Jan T1 - Neue Möglichkeiten elektrischer Anschlüsse an die Bewehrung und Untersuchung der Wirkung von Blitzströmen in bewehrtem Beton N2 - Im Rahmen eines modernen Blitzschutzsystems für Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Gebäude-Blitzschutz übernehmen [1]; - Sie kann, ggf. bei entsprechender Ergänzung, als ein geschlossener Käfig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grundsätzlich gleichermaßen bei Neubauten wie auch bei Ertüchtigungen möglich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ertüchtigungsmaßnahme für den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schränke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei größeren Gebäuden die elektromagnetische Schirmwirkung durch die elektrische Überbrückung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend überbrückt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Gebäude an Kabelstrecken, die über die Dehnfuge hinwegführen, rel. hohe Spannungen induziert werden können [2, 3]. Die sich um das gesamte Gebäude herumziehende oder zwischen zwei Gebäuden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern überbrückt werden. Im Falle von Blitzschutz-Ertüchtigungen in vorhandenen Gebäuden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großflächig (∅ wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfläche wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den über den Anschluss fließenden Strom bereits auf mehrere Bewehrungsstäbe zu verteilen. Dazu sind entweder die kreuzenden Stäbe zu verschweißen oder es sind direkt Anschlüsse an zwei Bewehrungsstäbe herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonlöcher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur Überbrückung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit würde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere für den Einsatz bei Blitzschutz-Ertüchtigungen in bestehenden Gebäuden vorgesehen. Abschließend sollen deshalb die Möglichkeiten zur Prüfung korrekter Anschlüsse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden. KW - Blitzschutz KW - Stahlbetonkonstruktion KW - Lightning Protection KW - reinforced concrete Y1 - 2001 ER -