TY - CHAP A1 - Bechstedt, U. A1 - Berg, Georg P. A. A1 - Hacker, U. A1 - Hardt, Arno A1 - Hürlimann, W. A1 - Maier, R. A1 - Martin, S. A1 - Meissburger, J. A1 - Römer, J. G. M. A1 - Possen, P. von A1 - Sagefka, T. T1 - BIG KARL and COSY T2 - The art and science of magnet design. A Festschrift in honor of Klaus Halbach. Vol. 1 Y1 - 1995 SP - 19 EP - 28 PB - Lawrence Berkeley Lab., Univ. of California CY - Berkeley, CA. ER - TY - JOUR A1 - Bechstedt, U. A1 - Haas, H. A1 - Hacker, U. A1 - Hardt, Arno A1 - Henn, K. A1 - Martin, S. A1 - Wimmer, J. T1 - Magnets for the German Spallation Source SNQ JF - IEEE transactions on nuclear science. Vol. 32, iss. 5 Y1 - 1985 SN - 1558-1578 (E-Journal); 0018-9499 (Print) SP - 3631 EP - 3633 ER - TY - CHAP A1 - Martin, S. A1 - Berg, G. A1 - Hardt, Arno A1 - Hürlimann, W. A1 - Köhler, M. A1 - Meißberger, J. A1 - Sagefka, T. A1 - Schult, O. W. B. ED - Sanderson, N. E. T1 - First experience with the magnet spectrometer 'BIG KARL' T2 - Use of magnetic spectrometers in nuclear physics : proceedings of the Daresbury study weekend 10 - 11 March 1979 Y1 - 1979 SP - 38 EP - 42 PB - Daresbury Lab. CY - Daresbury ER - TY - JOUR A1 - Hardt, Arno A1 - Martin, S. A1 - Meißburger, J. A1 - Retz, R. A1 - Wimmer, J. T1 - The cryopump system of the QQDDQ magnet spectrometer BIG KARL JF - Vacuum N2 - Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves. The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm. The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented. Y1 - 1978 U6 - http://dx.doi.org/10.1016/S0042-207X(78)80026-8 SN - 1879-2715 (E-Journal); 0042-207X (Print) VL - 28 IS - 10-11 SP - 483 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Hardt, Arno A1 - Abdel-Gawad, A A1 - Martin, S. A1 - Reich, J. T1 - Design procedures for the Juelich QQDDQ high resolution spectrometer T2 - Proceedings, 5th International Conference on Magnet Technology (MT-5) : Rome, Italy, April 21-25, 1975 Y1 - 1975 SP - 45 EP - 51 ER -