TY - JOUR A1 - Guo, Yuanyuan A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Device simulation of the light-addressable potentiometric sensor for the investigation of the spatial resolution JF - Sensors and actuators B: Chemical N2 - As a semiconductor-based electrochemical sensor, the light-addressable potentiometric sensor (LAPS) can realize two dimensional visualization of (bio-)chemical reactions at the sensor surface addressed by localized illumination. Thanks to this imaging capability, various applications in biochemical and biomedical fields are expected, for which the spatial resolution is critically significant. In this study, therefore, the spatial resolution of the LAPS was investigated in detail based on the device simulation. By calculating the spatiotemporal change of the distributions of electrons and holes inside the semiconductor layer in response to a modulated illumination, the photocurrent response as well as the spatial resolution was obtained as a function of various parameters such as the thickness of the Si substrate, the doping concentration, the wavelength and the intensity of illumination. The simulation results verified that both thinning the semiconductor substrate and increasing the doping concentration could improve the spatial resolution, which were in good agreement with known experimental results and theoretical analysis. More importantly, new findings of interests were also obtained. As for the dependence on the wavelength of illumination, it was found that the known dependence was not always the case. When the Si substrate was thick, a longer wavelength resulted in a higher spatial resolution which was known by experiments. When the Si substrate was thin, however, a longer wavelength of light resulted in a lower spatial resolution. This finding was explained as an effect of raised concentration of carriers, which reduced the thickness of the space charge region. The device simulation was found to be helpful to understand the relationship between the spatial resolution and device parameters, to understand the physics behind it, and to optimize the device structure and measurement conditions for realizing higher performance of chemical imaging systems. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.snb.2014.08.016 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 204 SP - 659 EP - 665 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Khaydukova, M. M. A1 - Zadorozhnaya, O. A. A1 - Kirsanov, D. O. A1 - Iken, Heiko A1 - Rolka, David A1 - Schöning, Michael Josef A1 - Babain, V. A. A1 - Vlasov, Yu. G. A1 - Legin, A. V. T1 - Multivariate processing of atomic-force microscopy images for detection of the response of plasticized polymeric membranes JF - Russian journal of applied chemistry N2 - The possibility of using the atomic-force microscopy as a method for detection of the analytical signal from plasticized polymeric sensor membranes was analyzed. The surfaces of cadmium-selective membranes based on two polymeric matrices were examined. The digital images were processed with multivariate image analysis techniques. A correlation was found between the surface profile of an ion-selective membrane and the concentration of the ion in solution. Y1 - 2014 U6 - http://dx.doi.org/10.1134/S1070427214030112 SN - 1608-3296 (E-Journal); 1070-4272 (Print) VL - 87 IS - 3 SP - 307 EP - 314 PB - Springer CY - Dordrecht ER - TY - CHAP A1 - Buniatyan, V. V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Rustamyan, L. G. A1 - Hovnikyan, H. H. T1 - Equivalent circuit and optimization of impedance characteristics of an electrolyte conductivity sensor T2 - Proceedings of State Engineering University Armenia : Series Information technologies, electronics, radio engineering Y1 - 2014 VL - Iss. 17 IS - No. 1 SP - 69 EP - 76 ER - TY - JOUR A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Stresses produced by different textile mesh implants in a tissue equivalent JF - BioNanoMaterials N2 - Two single-incision mini-slings used for treating urinary incontinence in women are compared with respect to the stresses they produce in their surrounding tissue. In an earlier paper we experimentally observed that these implants produce considerably different stress distributions in a muscle tissue equivalent. Here we perform 2D finite element analyses to compare the shear stresses and normal stresses in the tissue equivalent for the two meshes and to investigate their failure behavior. The results clearly show that the Gynecare TVT fails for increasing loads in a zipper-like manner because it gradually debonds from the surrounding tissue. Contrary to that, the tissue at the ends of the DynaMesh-SIS direct may rupture but only at higher loads. The simulation results are in good agreement with the experimental observations thus the computational model helps to interpret the experimental results and provides a tool for qualitative evaluation of mesh implants. Y1 - 2014 U6 - http://dx.doi.org/10.1515/bnm-2014-0003 SN - 2191-4672 (E-Journal); 2193-066X (E-Journal); 0011-8656 (Print); 1616-0177 (Print); 2193-0651 (Print) VL - 15 IS - 1-2 SP - 25 EP - 30 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Glück, Olaf A1 - Thust, Marion T1 - Electrochemical methods for the determination of chemical variables in aqueous media T2 - Measurement, instrumentation, and sensors handbook / ed. by John G. Webster [u.a.] Vol. 2 : Electromagnetic, optical, radiation, chemical, and biomedical measurement Y1 - 2014 SN - 978-1-4398-4891-3 SP - 55-1 EP - 55-54 PB - CRC Pr. CY - Boca Raton, Fla. ER - TY - CHAP A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Buniatyan, V. A1 - Schöning, Michael Josef T1 - Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 5 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Werner, Frederik A1 - Yoshinobu, T. A1 - Miyamoto, K. A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Semiconductor-based sensors for imaging of chemical processes T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 5 PB - VDE-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Wu, Chunsheng A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - DNA-hybridization detection using light-addressable potentiometric sensor modified with gold layer T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 4 PB - VDE-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Flexible polyimide-based calorimetric gas sensors for monitoring hy-drogen peroxide in sterilisation processes of aseptic filling machines T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 4 PB - VDE-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Sensor system for the monitoring of degradation processes of biodegradable biopolymers T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 4 PB - VDE-Verl. CY - Düsseldorf ER -