TY - CHAP A1 - Arida, Hassan A. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations N2 - A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors. KW - Biosensor KW - Heavy metal detection KW - thin-film microsensors KW - organic PVC membranes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1545 ER - TY - CHAP A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Mlynek, D. A1 - Hataihimakul, S. A1 - Pedraza, A. A1 - Dhawan, S. A1 - Laube, N. A1 - Kleinen, L. A1 - Baldsiefen, G. A1 - Busch, H. A1 - Schöning, Michael Josef T1 - Ion-selective sensors for the determination of the risk of urinary stone formation T2 - Micro- and Nanosystems in biochemical diagnosis : Principles and applications Y1 - 2010 SP - 74 EP - 80 CY - Warsaw ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Stütz, Evamaria A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Detection of toxic chromium species in water using cellbased sensor systems Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/P2.1.14 SP - 1364 EP - 1367 ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Living cell-based gas sensor system for the detection of acetone in air Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/3.2.3 SP - 269 EP - 272 ER - TY - CHAP A1 - Breuer, Lars A1 - Raue, Markus A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications T2 - 12. Dresdner Sensor-Symposium 2015 Y1 - 2015 U6 - http://dx.doi.org/10.5162/12dss2015/P5.8 SP - 206 EP - 209 ER - TY - CHAP A1 - Buniatyan, V. V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Rustamyan, L. G. A1 - Hovnikyan, H. H. T1 - Equivalent circuit and optimization of impedance characteristics of an electrolyte conductivity sensor T2 - Proceedings of State Engineering University Armenia : Series Information technologies, electronics, radio engineering Y1 - 2014 VL - Iss. 17 IS - No. 1 SP - 69 EP - 76 ER - TY - CHAP A1 - Bäcker, Matthias A1 - Koch, C. A1 - Geiger, F. A1 - Eber, F. A1 - Gliemann, H. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - A New Class of Biosensors Based on Tobacco Mosaic Virus and Coat Proteins as Enzyme Nanocarrier T2 - Procedia Engineering Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.proeng.2016.11.228 SN - 1877-7058 N1 - Proceedings of the 30th anniversary Eurosensors Conference – Eurosensors 2016, 4-7. Sepember 2016, Budapest, Hungary VL - Vol. 168 SP - 618 EP - 621 ER - TY - CHAP A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Sensor system for the monitoring of degradation processes of biodegradable biopolymers T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 4 PB - VDE-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Ermelenko, Y. A1 - Yoshinobu, T. A1 - Mourzina, Y. A1 - Schöning, Michael Josef A1 - Vlasov, Y. A1 - Iwasaki, H. T1 - A multisensor based on laser scanned silicon transducer (LSST): development and properties T2 - Eurosensors XVII : the 17th European Conference on Solid-State Transducers ; University of Minho, Guimarães, Portugal, September 21 - 24, 2003 Y1 - 2003 SP - 72 EP - 73 ER - TY - CHAP A1 - Förster, Arnold A1 - Stock, Jürgen A1 - Montanari, Simone A1 - Lepsa, Mihail Ion A1 - Lüth, Hans T1 - Fabrication and characterisation of GaAs Gunn Diode Chips for applications at 77 GHz in automotive industry N2 - GaAs-based Gunn diodes with graded AlGaAs hot electron injector heterostructures have been developed under the special needs in automotive applications. The fabrication of the Gunn diode chips was based on total substrate removal and processing of integrated Au heat sinks. Especially, the thermal and RF behavior of the diodes have been analyzed by DC, impedance and S-parameter measurements. The electrical investigations have revealed the functionality of the hot electron injector. An optimized layer structure could fulfill the requirements in adaptive cruise control (ACC) systems at 77 GHz with typical output power between 50 and 90 mW. KW - Biosensor KW - Gunn diode KW - microwave generation KW - GaAs hot electron injector Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1462 ER -