TY - JOUR A1 - Göttsche, Joachim A1 - Alexopoulos, Spiros A1 - Dümmler, Andreas A1 - Maddineni, S. K. T1 - Multi-Mirror Array Calculations With Optical Error N2 - The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles. KW - solar process heat KW - concentrating collector KW - raytracing KW - point-focussing system Y1 - 2019 SP - 1 EP - 6 ER - TY - JOUR A1 - Gorzalka, Philip A1 - Schmiedt, Jacob Estevam A1 - Schorn, Christian T1 - Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery JF - Buildings N2 - An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment. KW - Modelica KW - heat transfer coefficient KW - heat demand KW - building energy modelling KW - building energy simulation Y1 - 2021 U6 - http://dx.doi.org/10.3390/buildings11090380 SN - 2075-5309 N1 - This article belongs to the Special Issue "Application of Computer Technology in Buildings" VL - 11 IS - 9 PB - MDPI CY - Basel ER - TY - JOUR A1 - Peere, Wouter A1 - Blanke, Tobias ED - Vernon, Chris T1 - GHEtool: An open-source tool for borefield sizing in Python JF - Journal of Open Source Software N2 - GHEtool is a Python package that contains all the functionalities needed to deal with borefield design. It is developed for both researchers and practitioners. The core of this package is the automated sizing of borefield under different conditions. The sizing of a borefield is typically slow due to the high complexity of the mathematical background. Because this tool has a lot of precalculated data, GHEtool can size a borefield in the order of tenths of milliseconds. This sizing typically takes the order of minutes. Therefore, this tool is suited for being implemented in typical workflows where iterations are required. GHEtool also comes with a graphical user interface (GUI). This GUI is prebuilt as an exe-file because this provides access to all the functionalities without coding. A setup to install the GUI at the user-defined place is also implemented and available at: https://www.mech.kuleuven.be/en/tme/research/thermal_systems/tools/ghetool. KW - geothermal KW - energy KW - borefields KW - sizing Y1 - 2022 U6 - http://dx.doi.org/10.21105/joss.04406 SN - 2475-9066 VL - 7 IS - 76 SP - 1 EP - 4, 4406 ER - TY - JOUR A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz T1 - Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenkühltürmen JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Zwangsbelüftete Nasskühltürme haben im Gegensatz zur Trockenkühlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßkühlung die spezifische Kühlleistung durch abgeführte Kondensationswärme höher als bei der Trockenkühlung. Hybridzellenkühltürme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftströme die Wasserdampf-Sättigungsgrenze nicht überschreitet. Durch das Mischungsverhältnis kann man den gewünschten Sättigungsgrad einstellen. Je dichter dieser an der Sättigungsgrenze liegt, desto höher ist die Kühlleistung. Der von unten zugeführte Luftstrom der Naßkühlung und der seitlich zugeführte trockene Abluftstrom müssen sehr gut durchmischt werden, um über den gesamten Austrittsquerschnitt des Kühlturms die Sättigungsgrenze nicht zu überschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. Über ein Raster von 10 mal 10 Punkten wurde die örtliche Temperaturverteilung ermittelt. Wärmebilanzen ergeben dann die Mischungsgüte in einer Ebene oberhalb der Zellenkrone. Während ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 % liegt erhöhen Einbauten den Trockenluftanteil auf 30 % bis über 40 %. Dabei wurde die Trockenluft auf jeder Kühlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftauslässe umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gewünschten Mittelwert zeigen Potential für die weitere Verbesserung der Einbauten. KW - Trockenkühlturm KW - Nasskühlturm KW - kombiniertes Verfahren KW - Mischen KW - Abluft Y1 - 2000 SN - 1436-5103 VL - 51 IS - 8 SP - 48 EP - 49 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Timmer, H. T1 - Energetische und betriebswirtschaftliche Bewertung von Kühlsystemen für Kühllager JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 1998 SN - 1436-5103 VL - 49 IS - 9 SP - 74 EP - 77 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. T1 - Quo Vadis - Ausblick in die Gebäudeleittechnik der Zukunft T1 - Whitherfacility management? An outlook to the future JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerstände bei der Durchdringung des Marktes. N2 - Producers and planners of facility management systems are still faced with building owners' reluctance, especially when it comes to private homes. Y1 - 2005 SN - 1436-5103 VL - 56 IS - 1 SP - 39 EP - 41 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. A1 - Groß, H. T1 - Gebäudeautomation - Betriebsdatenerfassung und Gebäudeleittechnik im Klartext T1 - Operating data- and facility management in clear JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 2003 SN - 1436-5103 VL - 54 IS - 2 SP - 81 PB - Springer CY - Düsseldorf ER -