TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering N2 - In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure. Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 17 EP - 20 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Schermutzki, Margret ED - Terbuyken, Gregor T1 - In Modulen lehren, lernen und prüfen T2 - In Modulen lehren, lernen und prüfen. Herausforderungen an die Hochschuldidaktik Y1 - 2010 SN - 978-3-8172-7809-1 N1 - Dokumentation einer Tagung der Evangelischen Akademie Loccum vom 14. bis 16. Dezember 2009 in Kooperation mit der ZEvA Hannover und der Universität Hannover. SP - 81 EP - 106 PB - Evangelische Akademie Loccum CY - Rehburg-Loccum ER - TY - CHAP A1 - Bragard, Michael A1 - Soltau, N. A1 - De Doncker, R. W. A1 - Schmiegel, A. T1 - Design and implementation of a 5 kW photovoltaic system with li-ion battery and additional DC-DC converter T2 - 2010 IEEE Energy Conversion Congress and Exposition (ECCE 2010) : Atlanta, Georgia, USA, 12 - 16 September 2010 / [sponsored by the IEEE Power Electronics and Industry Applications Societies] Y1 - 2010 SN - 978-1-4244-5286-6 (Print) SN - 978-1-4244-5287-3 (Online) U6 - https://doi.org/10.1109/ECCE.2010.5618220 SP - 2944 EP - 2949 PB - IEEE CY - Piscataway, NJ ER -