TY - JOUR A1 - Herrmann, Ulf A1 - Schwarzenbart, Marc A1 - Dittmann-Gabriel, Sören A1 - May, Martin T1 - Hochtemperatur-Wärmespeicher für die Strom- und Wärmewende JF - Solarzeitalter : Politik, Kultur und Ökonomie erneuerbarer Energien Y1 - 2019 SN - 0937-3802 VL - 31 IS - 2 SP - 18 EP - 23 ER - TY - JOUR A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir A1 - Turichin, Gleb A1 - Valdaitseva, Elena A1 - Bach, Friedrich-Wilhelm A1 - Hassel, Thomas A1 - Beniyashi, Alexander T1 - Investigation of factors influencing the formation of weld defects in non-vacuum electron beam welding JF - The Paton welding journal N2 - The influence of welding condition parameters and properties of material on formation of defects, such as humping and undercuts, in non-vacuum electron beam welding was investigated. The influence of separate welding parameters on the quality of welds was determined. Y1 - 2012 SN - 0957-798X VL - 2012 IS - 2 SP - 11 EP - 18 PB - Paton Publishing House CY - Kiev ER - TY - JOUR A1 - Blanke, Tobias A1 - Reger, Vitali A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Kuhnhenne, Markus T1 - Koaxiale Stahlenergiepfähle JF - Stahlbau N2 - Ein entscheidender Teil der Energiewende ist die Wärmewende im Gebäudesektor. Ein Schlüsselelement sind hier Wärmepumpen. Diese benötigen eine Wärmequelle, der sie Energie entziehen können, um sie auf ein höheres Temperaturniveau zu transformieren. Diese Wärmequelle kann bspw. das Erdreich sein, dessen Wärme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpfähle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bezüglich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepfähle bieten neben der Wärmegewinnung weitere Vorteile, da sie auch eine statische Funktion übernehmen und rückstandsfrei zurückgebaut werden können. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepfähle in zwei verschiedenen Längen mit vorhandenen gängigen Erdsonden verglichen werden können. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 % und 148 % der Stahlenergiepfähle gegenüber dem Stand der Technik abhängig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von über 100 %. Es lässt sich also signifikante Erdsondenlänge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt. Y1 - 2021 VL - 90. 2021 IS - 6 SP - 417 EP - 424 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Göttsche, Joachim A1 - Hove, T. T1 - Mapping global, diffuse and beam solar radiation over Zimbabwe / T. Hove ; J. Göttsche JF - Renewable energy. 18 (1999), H. 4 Y1 - 1999 SN - 1879-0682 SP - 535 EP - 556 ER - TY - JOUR A1 - Vieira da Silva, Maria Eugenia A1 - Schwarzer, Klemens A1 - Hoffschmidt, Bernhard A1 - Pinheiro Rodrigues, Frederico A1 - Schwarzer, Tarik A1 - Costa Rocha, Paulo Alexandre T1 - Mass transfer correlation for evaporation–condensation thermal process in the range of 70 °C–95 °C JF - Renewable energy Y1 - 2013 SN - 1879-0682 (E-Journal); 0960-1481 (Print) VL - Vol. 53 SP - 174 EP - 179 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Göttsche, Joachim A1 - Alexopoulos, Spiros A1 - Dümmler, Andreas A1 - Maddineni, S. K. T1 - Multi-Mirror Array Calculations With Optical Error N2 - The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles. KW - solar process heat KW - concentrating collector KW - raytracing KW - point-focussing system Y1 - 2019 SP - 1 EP - 6 ER - TY - JOUR A1 - Meyer, S. A1 - Hänel, Matthias A1 - Beeh, B. A1 - Dittmann-Gabriel, Sören A1 - Dluhosch, R. A1 - May, Martin A1 - Herrmann, Ulf A1 - [und 5 weitere], T1 - Multifunktionaler thermischer Stromspeicher für die Strom- und Wärmeversorgung der Industrie von morgen JF - ETG Journal / Energietechnische Gesellschaft im VDE (ETG) Y1 - 2020 SN - 2625-9907 VL - 2020 IS - 1 SP - 6 EP - 9 ER - TY - JOUR A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Reger, Vitali A1 - Kuhnhenne, Markus T1 - Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates JF - Geothermal Energy N2 - Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics. Y1 - 2021 U6 - http://dx.doi.org/10.1186/s40517-021-00201-3 SN - 2195-9706 N1 - Corresponding author: Tobias Blanke VL - 9 IS - Article number: 19 PB - Springer CY - Berlin ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Ebbert, Thiemo A1 - Hachul, Helmut A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Nutzung erneuerbarer Energien durch thermische Aktivierung von Komponenten aus Stahl JF - Stahlbau N2 - Die Versorgung von Neubauten soll möglichst weitgehend unabhängig von fossilen Energieträgern erfolgen. Erneuerbare Energien spielen dafür eine gewichtige Rolle. Eine gute Möglichkeit, erneuerbare Energien ohne viel zusätzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Gebäude zusätzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule ergänzt werden. Auch Tiefgründungen können neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von Wärme erhalten. Neben der Erzeugung bietet sich auch für die Verteilung der Wärme oder Kälte im Gebäude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden. Im Rahmen der Veröffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine Lösung vorgestellt, die vorgehängte hinterlüftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei Möglichkeiten zur geothermischen Aktivierung von Tiefgründungen mittels Stahlpfählen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erläutert, welches Wärme zuführen oder bei Bedarf abführen kann. Y1 - 2020 U6 - http://dx.doi.org/10.1002/stab.202000031 SN - 1437-1049 VL - 2020 IS - Volume 89, Issue 6512-519 SP - 512 EP - 519 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Damm, Marc André A1 - Sauerborn, Markus A1 - Fend, Thomas A1 - Herrmann, Ulf T1 - Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element JF - Journal of ceramic science and technology Y1 - 2017 SN - 2190-9385 (Print) U6 - http://dx.doi.org/10.4416/JCST2016-00056 SN - 2190-9385 (Online) VL - 8 IS - 1 SP - 19 EP - 24 PB - Göller CY - Baden-Baden ER -