TY - JOUR A1 - Valero, Daniel A1 - Chanson, Hubert A1 - Bung, Daniel Bernhard T1 - Robust estimators for turbulence properties assessment Y1 - 2019 SP - 1 EP - 24 ER - TY - CHAP A1 - Bung, Daniel Bernhard T1 - Sensitivity of phase detection techniques in aerated chute flows to hydraulic design parameters T2 - 2nd European IAHR congress : 27. - 29. June 2012, München Y1 - 2012 SN - 978-3-943683-03-5 SP - Artikelkennnummer: B15 PB - Lehrstuhl u. Versuchsanst. für Wasserbau u. Wasserwirtschaft d. TU München CY - München ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - https://doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kerpen, Nils B. A1 - Bung, Daniel Bernhard A1 - Valero, Daniel A1 - Schlurmann, Torsten T1 - Energy dissipation within the wave run-up at stepped revetments JF - Journal of Ocean University of China Y1 - 2017 U6 - https://doi.org/10.1007/s11802-017-3355-z SN - 1993-5021 VL - 16 IS - 4 SP - 649 EP - 654 PB - Springer CY - Berlin ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Development of the interfacial air layer in the non-aerated region of high-velocity spillway flows: Instabilities growth, entrapped air and influence on the self-aeration onset JF - International Journal of Multiphase Flow N2 - Self-aeration is traditionally explained by the water turbulent boundary layer outer edge intersection with the free surface. This paper presents a discussion on the commonly accepted hypothesis behind the computation of the critical point of self-aeration in spillway flows and a new formulation is proposed based on the existence of a developing air flow over the free surface. Upstream of the inception point of self-aeration, some surface roughening has been often reported in previous studies which consequently implies some entrapped air transport and air–water flows coupling. Such air flow is proven in this study by presenting measured air velocities and computing the air boundary layer thickness for a 1V:2H smooth chute flow. Additionally, the growth rate of free surface waves has been analysed by means of Ultrasonic Sensors measurements, obtaining also the entrapped air concentration. High-speed camera imaging has been used for qualitative study of the flow perturbations. Y1 - 2016 U6 - https://doi.org/10.1016/j.ijmultiphaseflow.2016.04.012 SN - 0301-9322 VL - 84 SP - 66 EP - 74 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Bung, Daniel Bernhard A1 - Schlenkhoff, Andreas T1 - Self-aerated skimming flow on embankment stepped spillways : the effect of additional micro-roughness on energy dissipation and oxygen transfer T2 - Proceedings from first IAHR European congress : May 2010, Edinburgh Y1 - 2010 SN - 9780956595102 SP - Artikelkennnummer HSIIId PB - Heriot-Watt University, School of the Built Environment CY - Edinburgh ER - TY - CHAP A1 - Valero, Daniel A1 - Bung, Daniel Bernhard A1 - Crookston, B. M. A1 - Matos, J. ED - Crookston, B. ED - Tullis, B. T1 - Numerical investigation of USBR type III stilling basin performance downstream of smooth and stepped spillways BT - Session 1: Hydraulic structures T2 - Hydraulic Structures and Water System Management. 6th IAHR International Symposium on Hydraulic Structures, Portland, OR, 27-30 June 2016 Y1 - 2016 SN - 978-1-884575-75-4 U6 - https://doi.org/10.15142/T340628160853 SP - 635 EP - 646 ER - TY - JOUR A1 - Bung, Daniel Bernhard T1 - Non-intrusive detection of air–water surface roughness in self-aerated chute flows JF - Journal of hydraulic research Y1 - 2013 SN - 1814-2079 (E-Journal); 0022-1686 (Print) VL - Vol. 51 IS - Iss. 3 SP - 322 EP - 329 PB - Taylor & Francis CY - London ER - TY - RPRT A1 - Hebel, Christoph A1 - Merkens, Torsten A1 - Feyerl, Günter A1 - Kemper, Hans A1 - Busse, Daniel T1 - Elektromobilität - Verbundprojekt "COSTARTebus": Comprehensive strategy to accelerate the integration of electric-buses into existing public transport systems - Teilprojekt A : Berichtszeitraum: 01.01.2018-31.10.2020 Y1 - 2021 N1 - Förderkennzeichen BMVI 03EMEN10A Verbundnummer 01182550 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Bung, Daniel Bernhard T1 - Extreme flooding in Western Germany: some thoughts on hazards, return periods and risk JF - Hydrolink N2 - The low-pressure system Bernd involved extreme rainfalls in the Western part of Germany in July 2021, resulting in major floods, severe damages and a tremendous number of casualties. Such extreme events are rare and full flood protection can never be ensured with reasonable financial means. But still, this event must be starting point to reconsider current design concepts. This article aims at sharing some thoughts on potential hazards, the selection of return periods and remaining risk with the focus on Germany. Y1 - 2021 IS - 4 SP - 108 EP - 113 PB - International Association for Hydro-Environment Engineering and Research (IAHR) CY - Madrid ER -